Fully Automated Estimation of Spacing and Density for Retinal Mosaics

被引:15
作者
Cooper, Robert F. [1 ,2 ]
Aguirre, Geoffrey K. [3 ]
Morgan, Jessica I. W. [1 ,4 ]
机构
[1] Univ Penn, Scheie Eye Inst, Dept Ophthalmol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Psychol, 3815 Walnut St, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
[4] Univ Penn, Ctr Adv Retinal & Ocular Therapeut, Philadelphia, PA 19104 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2019年 / 8卷 / 05期
基金
美国国家卫生研究院;
关键词
adaptive optics; photo-receptor; cone density; PARAFOVEAL CONE DENSITY; PHOTORECEPTORS; IDENTIFICATION; ECCENTRICITY;
D O I
10.1167/tvst.8.5.26
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To introduce and validate a novel, fully automated algorithm for determining pointwise intercell distance (ICD) and cone density. Methods: We obtained images of the photoreceptor mosaic from 14 eyes of nine subjects without retinal pathology at two time points using an adaptive optics scanning laser ophthalmoscope. To automatically determine ICD, the radial average of the discrete Fourier transform (DFT) of the image was analyzed using a multiscale, fit-based algorithm to find the modal spacing. We then converted the modal spacing to ICD by assuming a hexagonally packed mosaic. The reproducibility of the algorithm was assessed between the two datasets, and accuracy was evaluated by comparing the results against those calculated from manually identified cones. Finally, the algorithm was extended to determine pointwise ICD and density in montages by calculating modal spacing over an overlapping grid of regions of interest (ROIs). Results: The differences of DFT-derived ICD between the test and validation datasets were 3.2% +/- 3.5% (mean +/- SD), consistent with the differences in directly calculated ICD (1.9% +/- 2.9%). The average ICD derived by the automated method was not significantly different between the development and validation datasets and was equivalent to the directly calculated ICD. When applied to a full montage, the automated algorithm produced estimates of cone density across retinal eccentricity that well match prior empiric measurements. Conclusions: We created an accurate, repeatable, and fully automated algorithm for determining ICD and density in both individual ROIs and across entire montages. Translational Relevance: The use of fully automated and validated algorithms will enable rapid analysis over the full photoreceptor montage.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] MULTICENTER VALIDATION OF FULLY AUTOMATED CAPILLARY ELECTROPHORESIS METHOD FOR DIAGNOSIS OF THALASSEMIAS AND HEMOGLOBINOPATHIES IN THAILAND
    Sangkitporn, Somchai
    Sangkitporn, Siripakorn K.
    Tanjatham, Sansanee
    Suwannakan, Boonnipa
    Rithapirom, Suthatip
    Yodtup, Chonlada
    Yowang, Amara
    Duangruang, Sawitree
    [J]. SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2011, 42 (05) : 1224 - 1232
  • [42] SPATIALLY INFORMED CNN FOR AUTOMATED CONE DETECTION IN ADAPTIVE OPTICS RETINAL IMAGES
    Jin, Heng
    Morgan, Jessica I. W.
    Gee, James C.
    Chen, Min
    [J]. 2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 1383 - 1386
  • [43] AMP2: A fully automated program for ab initio calculations of crystalline materials
    Youn, Yong
    Lee, Miso
    Hong, Changho
    Kim, Doyeon
    Kim, Sangtae
    Jung, Jisu
    Yim, Kanghoon
    Han, Seungwu
    [J]. COMPUTER PHYSICS COMMUNICATIONS, 2020, 256
  • [44] Automated techniques for blood vessels segmentation through fundus retinal images: A review
    Akbar, Shahzad
    Sharif, Muhammad
    Akram, Muhammad Usman
    Saba, Tanzila
    Mahmood, Toqeer
    Kolivand, Mahyar
    [J]. MICROSCOPY RESEARCH AND TECHNIQUE, 2019, 82 (02) : 153 - 170
  • [45] Fully-Automated Diagnosis of Aortic Stenosis Using Phonocardiogram-Based Features
    Saraf, Kanav
    Baek, Christopher I.
    Wasko, Michael H.
    Zhang, Xu
    Zheng, Yi
    Borgstrom, Per H.
    Mahajan, Aman
    Kaiser, William J.
    [J]. 2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6673 - 6676
  • [46] Fully automated software solution for protein quantitation by global metabolic labeling with stable isotopes
    Bindschedler, L. V.
    Cramer, R.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (11) : 1461 - 1471
  • [48] Automated Retinal Imaging System (ARIS) Compared with ETDRS Protocol Color Stereoscopic Retinal Photography to Assess Level of Diabetic Retinopathy
    Maker, Manvi P.
    Noble, Jason
    Silva, Paolo S.
    Cavallerano, Jerry D.
    Murtha, Timothy J.
    Sun, Jennifer K.
    Aiello, Lloyd M.
    Bursell, Sven-Erik
    Aiello, Lloyd Paul
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (06) : 515 - 522
  • [49] Wildcat population density on the Etna volcano, Italy: a comparison of density estimation methods
    Anile, S.
    Ragni, B.
    Randi, E.
    Mattucci, F.
    Rovero, F.
    [J]. JOURNAL OF ZOOLOGY, 2014, 293 (04) : 252 - 261
  • [50] Distribution of cone density, spacing and arrangement in adult healthy retinas with adaptive optics flood illumination
    Legras, Richard
    Gaudric, Alain
    Woog, Kelly
    [J]. PLOS ONE, 2018, 13 (01):