Fully Automated Estimation of Spacing and Density for Retinal Mosaics

被引:15
作者
Cooper, Robert F. [1 ,2 ]
Aguirre, Geoffrey K. [3 ]
Morgan, Jessica I. W. [1 ,4 ]
机构
[1] Univ Penn, Scheie Eye Inst, Dept Ophthalmol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Psychol, 3815 Walnut St, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
[4] Univ Penn, Ctr Adv Retinal & Ocular Therapeut, Philadelphia, PA 19104 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2019年 / 8卷 / 05期
基金
美国国家卫生研究院;
关键词
adaptive optics; photo-receptor; cone density; PARAFOVEAL CONE DENSITY; PHOTORECEPTORS; IDENTIFICATION; ECCENTRICITY;
D O I
10.1167/tvst.8.5.26
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To introduce and validate a novel, fully automated algorithm for determining pointwise intercell distance (ICD) and cone density. Methods: We obtained images of the photoreceptor mosaic from 14 eyes of nine subjects without retinal pathology at two time points using an adaptive optics scanning laser ophthalmoscope. To automatically determine ICD, the radial average of the discrete Fourier transform (DFT) of the image was analyzed using a multiscale, fit-based algorithm to find the modal spacing. We then converted the modal spacing to ICD by assuming a hexagonally packed mosaic. The reproducibility of the algorithm was assessed between the two datasets, and accuracy was evaluated by comparing the results against those calculated from manually identified cones. Finally, the algorithm was extended to determine pointwise ICD and density in montages by calculating modal spacing over an overlapping grid of regions of interest (ROIs). Results: The differences of DFT-derived ICD between the test and validation datasets were 3.2% +/- 3.5% (mean +/- SD), consistent with the differences in directly calculated ICD (1.9% +/- 2.9%). The average ICD derived by the automated method was not significantly different between the development and validation datasets and was equivalent to the directly calculated ICD. When applied to a full montage, the automated algorithm produced estimates of cone density across retinal eccentricity that well match prior empiric measurements. Conclusions: We created an accurate, repeatable, and fully automated algorithm for determining ICD and density in both individual ROIs and across entire montages. Translational Relevance: The use of fully automated and validated algorithms will enable rapid analysis over the full photoreceptor montage.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A fully organic retinal prosthesis restores vision in a rat model of degenerative blindness
    Maya-Vetencourt, Jose Fernando
    Ghezzi, Diego
    Antognazza, Maria Rosa
    Colombo, Elisabetta
    Mete, Maurizio
    Feyen, Paul
    Desii, Andrea
    Buschiazzo, Ambra
    Di Paolo, Mattia
    Di Marco, Stefano
    Ticconi, Flavia
    Emionite, Laura
    Shmal, Dmytro
    Marini, Cecilia
    Donelli, Ilaria
    Freddi, Giuliano
    Maccarone, Rita
    Bisti, Silvia
    Sambuceti, Gianmario
    Pertile, Grazia
    Lanzani, Guglielmo
    Benfenati, Fabio
    NATURE MATERIALS, 2017, 16 (06) : 681 - +
  • [32] A fully automatic method for segmenting retinal artery walls in adaptive optics images
    Lerme, Nicolas
    Rossant, Florence
    Bloch, Isabelle
    Paques, Michel
    Koch, Edouard
    Benesty, Jonathan
    PATTERN RECOGNITION LETTERS, 2016, 72 : 72 - 81
  • [33] Combined state and parameter estimation for not fully observable dynamic systems
    Backi, Christoph Josef
    Gravdahl, Jan Tommy
    Skogestad, Sigurd
    IFAC JOURNAL OF SYSTEMS AND CONTROL, 2020, 13
  • [34] MULTIPLE FAULT PARAMETER ESTIMATION OF A FULLY ASSEMBLED TURBOGENERATOR SYSTEM
    Lal, Mohit
    ARCHIVE OF MECHANICAL ENGINEERING, 2018, 65 (02) : 233 - 252
  • [35] Automated Quantitative Assessment of Retinal Fluid Volumes as Important Biomarkers in Degeneration
    Keenan, Tiarnan D. L.
    Chakravarthy, Usha
    Loewenstein, Anat
    Chew, Emily Y.
    Schmidt-Erfurth, Ursula
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 224 : 267 - 281
  • [36] Automated microaneurysm detection algorithms applied to diabetic retinopathy retinal images
    Sopharak, Akara
    Uyyanonvara, Bunyarit
    Barman, Sarah
    MAEJO INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLOGY, 2013, 7 (02) : 294 - 314
  • [37] Fully Automated Detection and Quantification of Macular Fluid in OCT Using Deep Learning
    Schlegl, Thomas
    Waldstein, Sebastian M.
    Bogunovic, Hrvoje
    Endstrasser, Franz
    Sadeghipour, Amir
    Philip, Ana-Maria
    Podkowinski, Dominika
    Gerendas, Bianca S.
    Langs, Georg
    Schmidt-Erfurth, Ursula
    OPHTHALMOLOGY, 2018, 125 (04) : 549 - 558
  • [38] AUTOMATED FOVEA CENTER ESTIMATION IN ADAPTIVE OPTICS IMAGES
    Valterova, Eva
    PROCEEDINGS II OF THE 26TH CONFERENCE STUDENT EEICT 2020, 2020, : 141 - 145
  • [39] Variation of Cone Photoreceptor Packing Density with Retinal Eccentricity and Age
    Song, Hongxin
    Chui, Toco Yuen Ping
    Zhong, Zhangyi
    Elsner, Ann E.
    Burns, Stephen A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7376 - 7384
  • [40] DataPype: A Fully Automated Unified Software Platform for Computer-Aided Drug Design
    Khan, Mohemmed Faraz
    Kandwal, Shubhangi
    Fayne, Darren
    ACS OMEGA, 2023, 8 (42): : 39468 - 39480