Fully Automated Estimation of Spacing and Density for Retinal Mosaics

被引:15
作者
Cooper, Robert F. [1 ,2 ]
Aguirre, Geoffrey K. [3 ]
Morgan, Jessica I. W. [1 ,4 ]
机构
[1] Univ Penn, Scheie Eye Inst, Dept Ophthalmol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Psychol, 3815 Walnut St, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
[4] Univ Penn, Ctr Adv Retinal & Ocular Therapeut, Philadelphia, PA 19104 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2019年 / 8卷 / 05期
基金
美国国家卫生研究院;
关键词
adaptive optics; photo-receptor; cone density; PARAFOVEAL CONE DENSITY; PHOTORECEPTORS; IDENTIFICATION; ECCENTRICITY;
D O I
10.1167/tvst.8.5.26
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To introduce and validate a novel, fully automated algorithm for determining pointwise intercell distance (ICD) and cone density. Methods: We obtained images of the photoreceptor mosaic from 14 eyes of nine subjects without retinal pathology at two time points using an adaptive optics scanning laser ophthalmoscope. To automatically determine ICD, the radial average of the discrete Fourier transform (DFT) of the image was analyzed using a multiscale, fit-based algorithm to find the modal spacing. We then converted the modal spacing to ICD by assuming a hexagonally packed mosaic. The reproducibility of the algorithm was assessed between the two datasets, and accuracy was evaluated by comparing the results against those calculated from manually identified cones. Finally, the algorithm was extended to determine pointwise ICD and density in montages by calculating modal spacing over an overlapping grid of regions of interest (ROIs). Results: The differences of DFT-derived ICD between the test and validation datasets were 3.2% +/- 3.5% (mean +/- SD), consistent with the differences in directly calculated ICD (1.9% +/- 2.9%). The average ICD derived by the automated method was not significantly different between the development and validation datasets and was equivalent to the directly calculated ICD. When applied to a full montage, the automated algorithm produced estimates of cone density across retinal eccentricity that well match prior empiric measurements. Conclusions: We created an accurate, repeatable, and fully automated algorithm for determining ICD and density in both individual ROIs and across entire montages. Translational Relevance: The use of fully automated and validated algorithms will enable rapid analysis over the full photoreceptor montage.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Fully automated breast boundary and pectoral muscle segmentation in mammograms
    Rampun, Andrik
    Morrow, Philip J.
    Scotney, Bryan W.
    Winder, John
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2017, 79 : 28 - 41
  • [22] Spice authentication by fully automated chemical analysis with integrated chemometrics
    Ford, Paul W.
    Berger, Terry A.
    Jackoway, Gary
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1667
  • [23] Development of a fully automated system for delivering odors in an MRI environment
    Cuevas, Isabel
    Gerard, Benoit
    Plaza, Paula
    Lerens, Elodie
    Collignon, Olivier
    Grandin, Cecile
    De Volder, Anne G.
    Renier, Laurent
    BEHAVIOR RESEARCH METHODS, 2010, 42 (04) : 1072 - 1078
  • [24] In vivo assessment of foveal geometry and cone photoreceptor density and spacing in children
    Mirhajianmoghadam, Hanieh
    Jnawali, Ashutosh
    Musial, Gwen
    Queener, Hope M.
    Patel, Nimesh B.
    Ostrin, Lisa A.
    Porter, Jason
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [25] State and Parameter Estimation for Retinal Laser Treatment
    Kleyman, Viktoria
    Schaller, Manuel
    Mordmueller, Mario
    Wilson, Mitsuru
    Brinkmann, Ralf
    Worthmann, Karl
    Mueller, Matthias A.
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2023, 31 (03) : 1366 - 1378
  • [26] Fully automated diabetic retinopathy screening using morphological component analysis
    Imani, Elaheh
    Pourreza, Hamid-Reza
    Banaee, Touka
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 43 : 78 - 88
  • [27] An automated algorithm for photoreceptors counting in adaptive optic retinal images
    Liu, Xu
    Zhang, Yudong
    Dai, Yun
    6TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTOELECTRONIC MATERIALS AND DEVICES FOR SENSING, IMAGING, AND SOLAR ENERGY, 2012, 8419
  • [28] A fully automated colorimetric sensing device using smartphone for biomolecular quantification
    Dutta, Sibasish
    Nath, Pabitra
    OPTICS AND BIOPHOTONICS IN LOW-RESOURCE SETTINGS III, 2017, 10055
  • [29] Automated outlier detection and estimation of missing data
    Rhyu, Jinwook
    Bozinovski, Dragana
    Dubs, Alexis B.
    Mohan, Naresh
    Bende, Elizabeth M. Cummings
    Maloney, Andrew J.
    Nieves, Miriam
    Sangerman, Jose
    Lu, Amos E.
    Hong, Moo Sun
    Artamonova, Anastasia
    Ou, Rui Wen
    Barone, Paul W.
    Leung, James C.
    Wolfrum, Jacqueline M.
    Sinskey, Anthony J.
    Springs, Stacy L.
    Braatz, Richard D.
    COMPUTERS & CHEMICAL ENGINEERING, 2024, 180
  • [30] Assessment of parafoveal cone density in patients taking hydroxychloroquine in the absence of clinically documented retinal toxicity
    Debellemaniere, Guillaume
    Flores, Mathieu
    Tumahai, Perle
    Meillat, Mathieu
    Garnier, Melanie Bidaut
    Delbosc, Bernard
    Saleh, Maher
    ACTA OPHTHALMOLOGICA, 2015, 93 (07) : E534 - E540