Fully Automated Estimation of Spacing and Density for Retinal Mosaics

被引:15
|
作者
Cooper, Robert F. [1 ,2 ]
Aguirre, Geoffrey K. [3 ]
Morgan, Jessica I. W. [1 ,4 ]
机构
[1] Univ Penn, Scheie Eye Inst, Dept Ophthalmol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Psychol, 3815 Walnut St, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
[4] Univ Penn, Ctr Adv Retinal & Ocular Therapeut, Philadelphia, PA 19104 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2019年 / 8卷 / 05期
基金
美国国家卫生研究院;
关键词
adaptive optics; photo-receptor; cone density; PARAFOVEAL CONE DENSITY; PHOTORECEPTORS; IDENTIFICATION; ECCENTRICITY;
D O I
10.1167/tvst.8.5.26
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To introduce and validate a novel, fully automated algorithm for determining pointwise intercell distance (ICD) and cone density. Methods: We obtained images of the photoreceptor mosaic from 14 eyes of nine subjects without retinal pathology at two time points using an adaptive optics scanning laser ophthalmoscope. To automatically determine ICD, the radial average of the discrete Fourier transform (DFT) of the image was analyzed using a multiscale, fit-based algorithm to find the modal spacing. We then converted the modal spacing to ICD by assuming a hexagonally packed mosaic. The reproducibility of the algorithm was assessed between the two datasets, and accuracy was evaluated by comparing the results against those calculated from manually identified cones. Finally, the algorithm was extended to determine pointwise ICD and density in montages by calculating modal spacing over an overlapping grid of regions of interest (ROIs). Results: The differences of DFT-derived ICD between the test and validation datasets were 3.2% +/- 3.5% (mean +/- SD), consistent with the differences in directly calculated ICD (1.9% +/- 2.9%). The average ICD derived by the automated method was not significantly different between the development and validation datasets and was equivalent to the directly calculated ICD. When applied to a full montage, the automated algorithm produced estimates of cone density across retinal eccentricity that well match prior empiric measurements. Conclusions: We created an accurate, repeatable, and fully automated algorithm for determining ICD and density in both individual ROIs and across entire montages. Translational Relevance: The use of fully automated and validated algorithms will enable rapid analysis over the full photoreceptor montage.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Imaging retinal mosaics in the living eye
    Rossi, E. A.
    Chung, M.
    Dubra, A.
    Hunter, J. J.
    Merigan, W. H.
    Williams, D. R.
    EYE, 2011, 25 (03) : 301 - 308
  • [2] Eccentricity dependent changes of density, spacing and packing arrangement of parafoveal cones
    Lombardo, Marco
    Serrao, Sebastiano
    Ducoli, Pietro
    Lombardo, Giuseppe
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2013, 33 (04) : 516 - 526
  • [3] Imaging retinal mosaics in the living eye
    E A Rossi
    M Chung
    A Dubra
    J J Hunter
    W H Merigan
    D R Williams
    Eye, 2011, 25 : 301 - 308
  • [4] Automated Cone and Vessel Analysis in Adaptive Optics Like Retinal Images for Clinical Diagnostics Support
    Hertlein, Anna-Sophia
    Wesarg, Stefan
    Schmidt, Jessica
    Boche, Benjamin
    Pfeiffer, Norbert
    Matlach, Juliane
    CLINICAL IMAGE-BASED PROCEDURES, CLIP 2022, 2023, 13746 : 82 - 90
  • [5] Extracting spacing-derived estimates of rod density in healthy retinae
    Heitkotter, Heather
    Patterson, Emily J.
    Woertz, Erica N.
    Cava, Jenna A.
    Gaffney, Mina
    Adhan, Iniya
    Tam, Johnny
    Cooper, Robert F.
    Carroll, Joseph
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (01) : 1 - 17
  • [6] The Retinal Mosaics of Opsin Expression in Invertebrates and Vertebrates
    Rister, Jens
    Desplan, Claude
    DEVELOPMENTAL NEUROBIOLOGY, 2011, 71 (12) : 1212 - 1226
  • [7] Repeatability of Cone Spacing Measures in Eyes With Inherited Retinal Degenerations
    Zayit-Soudry, Shiri
    Sippl-Swezey, Nicolas
    Porco, Travis C.
    Lynch, Stephanie K.
    Syed, Reema
    Ratnam, Kavitha
    Menghini, Moreno
    Roorda, Austin J.
    Duncan, Jacque L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (10) : 6179 - 6189
  • [8] Fully Automated and Robust Cable Tension Estimation of Wireless Sensor Networks System
    Zhang, Min
    He, Huating
    Li, Gengying
    Wang, Haiyang
    SENSORS, 2021, 21 (21)
  • [9] Retinal vascular analysis in a fully automated method for the segmentation of DRT edemas using OCT images
    de Moura, Joaquim
    Novo, Jorge
    Charlon, Pablo
    Isabel Fernandez, Maria
    Ortega, Marcos
    KNOWLEDGE-BASED AND INTELLIGENT INFORMATION & ENGINEERING SYSTEMS (KES 2019), 2019, 159 : 600 - 609
  • [10] Repeatability of In Vivo Parafoveal Cone Density and Spacing Measurements
    Garrioch, Robert
    Langlo, Christopher
    Dubis, Adam M.
    Cooper, Robert F.
    Dubra, Alfredo
    Carroll, Joseph
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (05) : 632 - 643