Performance characteristics of a tandem spray chamber arrangement in double focusing sector field ICP-MS

被引:27
|
作者
Olofsson, RS
Rodushkin, I [1 ]
Axelsson, MD
机构
[1] Lulea Univ Technol, SGAB Analyt, S-97187 Lulea, Sweden
[2] Lulea Univ Technol, Div Appl Geol, S-97187 Lulea, Sweden
关键词
D O I
10.1039/b002609n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A tandem cyclone-Scott type spray chamber configuration combined with infrared heating and a low-flow Micromist nebulizer was evaluated for the use in a ICP-SFMS sample introduction system. The system provides about a 3-fold sensitivity gain and lower oxide formation compared to the standard introduction system, although matrix-induced signal suppression is more pronounced, especially for elements with high ionization potential. The technique was evaluated by accurate analysis of riverine water reference material SLRS-3 with generally good agreement with certified and literature values. Long-term precision at a 20 mu g l(-1) concentration level was 0.7% RSD in low resolution and 1.6% RSD in medium resolution. Precision in the range 0.03-0.09% RSD for lead isotope ratios at 1 mu g l(-1) was obtained.
引用
收藏
页码:727 / 729
页数:3
相关论文
共 50 条
  • [21] Double-focusing ICP-MS for the analysis of biological materials
    Juan Manuel Marchante-Gayón
    Analytical and Bioanalytical Chemistry, 2004, 379 : 335 - 337
  • [22] Assessment of the determination of 79selenium using double-focusing sector field ICP-MS after hydride generation
    Hoppstock, K
    Becker, JS
    Dietze, HJ
    ATOMIC SPECTROSCOPY, 1997, 18 (06) : 180 - 185
  • [23] Spectral interferences in the analysis of cadmium in human blood by ICP-MS: comparison between high resolution sector field ICP-MS and quadrupole ICP-MS
    Vrijens, Jan
    Couck, Pedro
    Schroijen, Carmen
    Baeyens, Willy
    Leermakers, Martine
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (09) : 1819 - 1826
  • [24] Application of sector-field ICP-MS and ICP-MS with collision cell for determination of phosphorus and iron in proteins
    Boulyga, SF
    Pickhardt, C
    Becker, JS
    Przybylski, M
    Becker, JS
    PLASMA SOURCE MASS SPECTROMETRY: APPLICATIONS AND EMERGING TECHNOLOGIES, 2003, : 54 - 65
  • [25] Application of double focusing magnetic sector high resolution ICP-MS to the study of iron stable isotope trace
    Jin, XD
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (02) : 220 - 222
  • [26] Application of double focusing sector field ICP-MS for multielemental characterization of human hair and nails. Part I. Analytical methodology
    Rodushkin, I
    Axelsson, MD
    SCIENCE OF THE TOTAL ENVIRONMENT, 2000, 250 (1-3) : 83 - 100
  • [27] Measurement of actinides at ultra-trace level by double-focusing sector-field ICP-MS:: Instrumental performances and analytical difficulties
    Pointurier, F.
    Baglan, N.
    Hemet, Ph.
    PLASMA SOURCE MASS SPECTROMETRY: CURRENT TRENDS AND FUTURE DEVELOPMENTS, 2005, (301): : 130 - 142
  • [28] High resolution sector field ICP-MS and multicollector ICP-MS as tools for trace metal speciation in environmental studies: a review
    Moldovan, M
    Krupp, EM
    Holliday, AE
    Donard, OFX
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (07) : 815 - 822
  • [29] 8th International Sector Field ICP-MS Conference
    Townsend, Ashley
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (07) : 921 - 922
  • [30] Determination of siderophile and chalcophile elements in peridotites by sector field ICP-MS
    Meier, L. C.
    Van Acken, D.
    Fischer-Goedde, M.
    Wombacher, F.
    Becker, H.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2007, 71 (15) : A649 - A649