Concrete filled steel tube stub columns under combined temperature and loading

被引:121
作者
Song, Tian-Yi [1 ]
Han, Lin-Hai [1 ]
Yu, Hong-Xia [1 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Key Lab Struct Engn & Vibrat, China Educ Minist, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Concrete-filled steel tube; Composite columns; Hollow sections; FEA model; Full range fire; Residual strength; FIRE RESISTANCE; STANDARD FIRE; BEHAVIOR;
D O I
10.1016/j.jcsr.2009.10.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A finite element analysis (FEA) model was developed to predict the load versus deformation relationships of concrete filled steel tube (CFST) stub columns subjected to a combination of temperature and axial compression. This model was used to Simulate a set of CFST stub column experiments under various thermal and mechanical loading conditions, including tests at high temperature, tests on the residual strength of specimens subjected to uniform heating, and tests on specimens exposed to the ISO-834 standard fire without initial loads. Comparisons between the predicted results and the test results show that this model can predict the load versus deformation relationships with reasonable accuracy. The FEA model was then used to investigate the behaviour of CFST stub columns in a complete loading history including initial loading, heating and cooling by examing the cross-sectional stress distribution and confinement stress development at different loading phases. All specimens were loaded to ultimate strength after cooling and the residual stress index was studied with respect to a group of parameters. It can be found that the ultimate strength when considering the mutual actions of temperature and loading was slightly lower than that after exposure to fire without initial load, but the peak strain corresponding to the ultimate strength was increased significantly. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:369 / 384
页数:16
相关论文
共 19 条
[1]  
*ASCCS, 1997, CONCR FILL STEEL TUB
[2]  
*EUR CONV CONSTR S, 1988, 3 ECCS TECHN COMM
[3]  
HAN L.H., 2007, Concrete-filled steel tubular structure-Theory and Practice
[4]   Compressive and flexural behaviour of concrete filled steel tubes after exposure to standard fire [J].
Han, LH ;
Huo, JS ;
Wang, YC .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (07) :882-901
[5]  
HASS R, 1991, REALISTIC TESTING FI
[6]  
*HIBB KARLS SOR IN, 2004, ABAQUS STAND US MAN
[7]   Analytical modeling of the standard fire behavior of loaded CFT columns [J].
Hong, Sangdo ;
Varma, Amit H. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (01) :54-69
[8]  
ISO (International Standards Organization), 1980, ISO-834: Fire Resistance Tests, Elements of Building Construction
[9]   Performance-based fire resistance design of concrete-filled steel columns [J].
Kodur, VKR .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1999, 51 (01) :21-36
[10]  
Lie T.T., 1992, 611 NRCCNRC