Influence of basis images and skull position on evaluation of cortical bone thickness in cone beam computed tomography

被引:10
作者
Chagas Nascimento, Monikelly do Carmo [1 ]
de Almeida Boscolo, Solange Maria [1 ]
Haiter-Neto, Francisco [1 ]
Dos Santos, Emanuela Carla [2 ]
Lambrichts, Ivo [3 ]
Pauwels, Ruben [4 ,5 ,6 ]
Jacobs, Reinhilde [4 ,5 ,7 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Sao Paulo, Brazil
[2] Pontificia Univ Catolica Parana, Curitiba, Parana, Brazil
[3] Biomed Res Inst, Lab Morphol, Hasselt, Belgium
[4] Univ Leuven, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[5] Univ Hosp Leuven, Oral & Maxillofacial Surg, Leuven, Belgium
[6] Chulalongkorn Univ, Fac Dent, Dept Radiol, Bangkok, Thailand
[7] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2017年 / 123卷 / 06期
关键词
IMMEDIATE IMPLANT PLACEMENT; DIAGNOSTIC-ACCURACY; ALVEOLAR PROCESS; AESTHETIC ZONE; PLATE; RELIABILITY; QUALITY; HEIGHT; FIELDS;
D O I
10.1016/j.oooo.2017.01.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The aim of this study was to assess the influence of the number of basis images and the orientation of the skull on the evaluation of cortical alveolar bone in cone beam computed tomography (CBCT). Study Design. Eleven skulls with a total of 59 anterior teeth were selected. CBCT images were acquired by using 4 protocols, by varying the rotation of the tube-detector arm and the orientation of the skull (protocol 1: 360(omicron)/0(omicron); protocol 2: 180(omicron)/0(omicron); protocol 3: 180(omicron)/90(omicron); protocol 4: 180(omicron)/180(omicron)). Observers evaluated cortical bone as absent, thin, or thick. Direct observation of the skulls was used as the gold standard. Intra- and interobserver agreement, as well as agreement of scoring between the 3 bone thickness classifications, were calculated by using the k statistic. The Wilcoxon signed-rank test was used to compare the 4 protocols. Results. For lingual cortical bone, protocol 1 showed no statistical difference from the gold standard. Higher reliability was found in protocol 3 for absent (k = 0.80) and thin (k = 0.47) cortices, whereas for thick cortical bone, protocol 2 was more consistent (k - 0.60). In buccal cortical bone, protocol 1 obtained the highest agreement for absent cortices (k - 0.61), whereas protocol 4 was better for thin cortical plates (k = 0.38) and protocol 2 for thick cortical plates (k = 0.40). Conclusions. No consistent effect of the number of basis images or head orientation for visual detection of alveolar bone was detected, except for lingual cortical bone, for which full rotation scanning showed improved visualization.
引用
收藏
页码:707 / 713
页数:7
相关论文
共 40 条
[1]   Surgical Correction of Horizontal Bone Defect Using the Lateral Maxillary Wall: Outcomes of a Retrospective Study [J].
Anitua, Eduardo ;
Hamdan Alkhraisat, Mohammad ;
Miguel-Sanchez, Alfonso ;
Orive, Gorka .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 72 (04) :683-693
[2]   Role of Cone Beam Computed Tomography in Rehabilitation of a Traumatised Deficient Maxillary Alveolar Ridge Using Symphyseal Block Graft Placement [J].
Arora, Shipra ;
Lamba, Arundeep Kaur ;
Faraz, Farrukh ;
Tandon, Shruti ;
Ahad, Abdul .
CASE REPORTS IN DENTISTRY, 2013, 2013
[3]   Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine [J].
Ballrick, John W. ;
Palomo, J. Martin ;
Ruch, Edward ;
Amberman, B. Douglas ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (04) :573-582
[4]   Cortical bone thickness and bone depth of the posterior palatal alveolar process for mini-implant insertion in adults [J].
Baumgaertel, Sebastian .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (06) :806-811
[5]   Reliability and accuracy of cone-beam computed tomography dental measurements [J].
Baumgaertel, Sebastian ;
Palomo, J. Martin ;
Palomo, Leena ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) :19-25
[6]   Evaluation of alveolar bone loss following rapid maxillary expansion using cone-beam computed tomography [J].
Baysal, Asli ;
Uysal, Tancan ;
Veli, Ilknur ;
Ozer, Torun ;
Karadede, Irfan ;
Hekimoglu, Seyit .
KOREAN JOURNAL OF ORTHODONTICS, 2013, 43 (02) :83-95
[7]   Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull [J].
Berco, Mauricio ;
Rigali, Paul H., Jr. ;
Miner, R. Matthew ;
DeLuca, Stephelynn ;
Anderson, Nina K. ;
Will, Leslie A. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) :17.e1-17.e9
[8]  
Braut V, 2011, INT J PERIODONT REST, V31, P125
[9]   Incidence of Implant Buccal Plate Fenestration in the Esthetic Zone: A Cone Beam Computed Tomography Study [J].
Chan, Hsun-Liang ;
Garaicoa-Pazmino, Carlos ;
Suarez, Fernando ;
Monje, Alberto ;
Benavides, Erika ;
Oh, Tae-Ju ;
Wang, Hom-Lay .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) :171-177
[10]  
Cook DR, 2011, INT J PERIODONT REST, V31, P345