Value of Stress Myocardial Perfusion Scanning in Diagnosis of Severe Coronary Artery Disease in Liver Transplantation Candidates

被引:43
|
作者
Aydinalp, A. [1 ]
Bal, U. [1 ]
Atar, I. [1 ]
Ertan, C. [1 ]
Aktas, A. [2 ]
Yildirir, A. [1 ]
Ozin, B. [1 ]
Mudderisoglu, H. [1 ]
Haberal, M. [3 ]
机构
[1] Baskent Univ, Fac Med, Dept Cardiol, TR-06490 Ankara, Turkey
[2] Baskent Univ, Fac Med, Dept Nucl Med, TR-06490 Ankara, Turkey
[3] Baskent Univ, Fac Med, Dept Gen Surg, TR-06490 Ankara, Turkey
关键词
ECHOCARDIOGRAPHY; DEATH;
D O I
10.1016/j.transproceed.2009.06.219
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. The significant potential for perioperative and late cardiovascular complications makes careful preoperative cardiac risk assessment imperative in liver transplantation candidates. Objective. To determine the sensitivity and specificity of myocardial perfusion scanning for detection of coronary artery disease (CAD) in liver transplantation candidates. Patients and Methods. We prospectively evaluated 93 liver transplantation candidates. Patients with known CAD were excluded. All patients, regardless of symptoms and risk factors, underwent myocardial perfusion scanning and coronary angiography. Results. Results of myocardial perfusion scanning were abnormal in 64 patients (68.8%) and normal in 29 patients (31.2%). Of patients with abnormal scans, only 6 (9.4%) had severe CAD at coronary angiography. None of the 29 patients with normal perfusion scans and the 24 patients with fixed defects had severe CAD; however, 6 of 40 patients (15.0%) with reversible perfusion defects had severe CAD at coronary angiography (P = .005). Alcoholic liver disease, reversible perfusion defects at myocardial perfusion scanning, left ventricular systolic dysfunction, and higher low-density lipoprotein (LDL) cholesterol and triglyceride levels were significantly associated with CAD. Defining reversible perfusion defects as a sign of ischemia, and fixed defects and normal perfusion as nonischemic, myocardial perfusion scanning had 100% sensitivity but 61% specificity for severe CAD. The test's accuracy was low (38%). Conclusions. The results of reversible perfusion defects on myocardial perfusion scanning were sensitive but not specific for CAD in liver transplantation candidates. The high number of false-positive results decreased the test's accuracy.
引用
收藏
页码:3757 / 3760
页数:4
相关论文
共 50 条
  • [11] MYOCARDIAL PERFUSION IMAGING IN THE DIAGNOSIS OF CORONARY-ARTERY DISEASE
    GO, RT
    MACINTYRE, WJ
    COOK, SA
    NEUMANN, DR
    CURRENT OPINION IN RADIOLOGY, 1992, 4 (04) : 23 - 33
  • [12] Diagnosis of coronary artery disease by radionuclide myocardial perfusion imaging
    Loong, CY
    Anagnostopoulos, C
    HEART, 2004, 90 : V2 - V9
  • [13] Cardiac stress testing and coronary artery disease in liver transplantation candidates: Meta-analysis
    Jonathan Soldera
    Fábio Camazzola
    Santiago Rodríguez
    Ajacio Brand?o
    World Journal of Hepatology, 2018, (11) : 877 - 886
  • [14] Cardiac stress testing and coronary artery disease in liver transplantation candidates: Meta-analysis
    Soldera, Jonathan
    Camazzola, Fabio
    Rodriguez, Santiago
    Brandao, Ajacio
    WORLD JOURNAL OF HEPATOLOGY, 2018, 10 (11) : 877 - 886
  • [15] Normal or near normal myocardial perfusion stress imaging in patients with severe coronary artery disease
    Diamond, Joseph A.
    Makaryus, Amgad N.
    Sandler, David A.
    Machac, Joseph
    Henzlova, Milena J.
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2008, 9 (08) : 820 - 825
  • [16] CLINICAL IMPLICATIONS OF MYOCARDIAL PERFUSION SCANNING IN CORONARY-ARTERY DISEASE
    ROTHBAUM, DA
    WELLMAN, HN
    KNOEBEL, SB
    AMERICAN JOURNAL OF CARDIOLOGY, 1976, 37 (01): : 168 - 168
  • [17] Severe coronary artery disease in patients with normal or near normal myocardial perfusion stress imaging
    Diamond, JA
    Sandler, DA
    Machac, J
    Henzlova, MJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 261A - 261A
  • [18] Predictive value of dobutamine stress echocardiography for coronary artery disease detection in liver transplant candidates
    Harinstein, M. E.
    Flaherty, J. D.
    Ansari, A. H.
    Robin, J.
    Davidson, C. J.
    Rossi, J. S.
    Flamm, S. L.
    Blei, A. T.
    Bonow, R. O.
    Abecassis, M.
    Gheorghiade, M.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2008, 8 (07) : 1523 - 1528
  • [19] Dobutamine stress myocardial perfusion imaging in coronary artery disease
    Elhendy, A
    Bax, JJ
    Poldermans, D
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (12) : 1634 - 1646
  • [20] Long-term prognostic value of coronary artery calcium scanning, coronary computed tomographic angiography and stress myocardial perfusion imaging in patients with suspected coronary artery disease
    Nappi, Carmela
    Nicolai, Emanuele
    Daniele, Stefania
    Acampa, Wanda
    Gaudieri, Valeria
    Assante, Roberta
    Zampella, Emilia
    Segreto, Sabrina
    Imbriaco, Massimo
    Petretta, Mario
    Salvatore, Marco
    Cuocolo, Alberto