Universal Primer-Multiplex PCR Approach for Simultaneous Detection of Escherichia coli, Listeria monocytogenes, and Salmonella spp. in Food Samples

被引:38
|
作者
Yuan, Yanfang [1 ]
Xu, Wentao [1 ,2 ]
Zhai, Zhifang [1 ]
Shi, Hui [1 ]
Luo, Yunbo [1 ]
Chen, Zhuojun [1 ]
Huang, Kunlun [1 ,2 ]
机构
[1] China Agr Univ, Coll Food Sci & Nutr Engn, Beijing 100083, Peoples R China
[2] Minist Agr, Supervis Inspect & Testing Ctr Genetically Modifi, Beijing 100083, Peoples R China
关键词
Escherichia coli; Listeria monocytogenes; Salmonella spp; simultaneous detection; universal primer-multiplex PCR; REAL-TIME PCR; POLYMERASE-CHAIN-REACTION; MULTISTATE OUTBREAK; RAPID DETECTION; O157-H7; INFECTION; ASSAYS; IDENTIFICATION; PATHOGENS; PRODUCTS;
D O I
10.1111/j.1750-3841.2009.01321.x
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Escherichia coli, Listeria monocytogenes, and Salmonella spp. are 3 kinds of the most important food-borne human pathogens. Traditional microbiological analysis is labor-intensive, time-consuming, and easily contaminated, thus producing false positive signals; it also involves much subjectivity judgments. Multiplex-PCR could be applied to detect multiple target organisms simultaneously to save time and labor, but there is always disproportionate amplification resulting from the disparity of different primers. To gain a rapid and sensitive method, a universal primer-multiplex PCR system (UP-M-PCR) was developed and applied for simultaneous detection of the 3 organisms. This method simplified traditional multiplex-PCR reaction system and overcame its amplification disparities among different primers; moreover, it got a high specificity and sensitivity (85, 155, and 104 copies/reaction for E. coli O157, L. monocytogenes, and Salmonella spp., respectively). Compared with the time-consuming and laborious microbiological analysis, UP-M-PCR had a lower risk of cross-contamination without inoculation and incubation. Test results for 36 food samples showed that UP-M-PCR method got a relative accuracy of 91.77% when compared with traditional microbiological analysis. It could serve as a rapid screening method for pathogen detection and could detect target genes even in dead pathogenic cells. In addition, it has the potential to be performed in an automation mode and might find broader application in simultaneous detection of other multiple pathogens.
引用
收藏
页码:M446 / M452
页数:7
相关论文
共 50 条
  • [21] A Multiplex PCR Assay for Simultaneous Detection of Escherichia coli O157:H7, Bacillus cereus, Vibrio parahaemolyticus, Salmonella spp., Listeria monocytogenes, and Staphylococcus aureus in Korean Ready-to-Eat Food
    Lee, Nari
    Kwon, Kyung Yoon
    Oh, Su Kyung
    Chang, Hyun-Joo
    Chun, Hyang Sook
    Choi, Sung-Wook
    FOODBORNE PATHOGENS AND DISEASE, 2014, 11 (07) : 574 - 580
  • [22] Rapid and simultaneous detection of Salmonella spp., Escherichia coli O157:H7, and Listeria monocytogenes in meat using multiplex immunomagnetic separation and multiplex real-time PCR
    Fan, Wei
    Gao, Xiao-yue
    Li, He-nan
    Guo, Wen-ping
    Li, Ying-ying
    Wang, Shou-wei
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2022, 248 (03) : 869 - 879
  • [23] Development of a multiplex real-time PCR method for simultaneous detection of Salmonella enterica, Shigella flexneri and Listeria monocytogenes in processed food samples
    Garrido, Alejandro
    Chapela, Maria-Jose
    Roman, Belen
    Ferreira, Martina
    Lago, Jorge
    Vieites, Juan M.
    Cabado, Ana G.
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2012, 234 (04) : 571 - 580
  • [24] Simultaneous detection of Listeria monocytogenes and Salmonella spp. in dairy products using real time PCR-melt curve analysis
    Singh, Jitender
    Batish, Virender K.
    Grover, Sunita
    JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 2012, 49 (02): : 234 - 239
  • [25] Multiplex PCR assay for the detection and quantification of Campylobacter spp., Escherichia coli O157:H7, and Salmonella serotypes in water samples
    Park, Si Hong
    Hanning, Irene
    Jarquin, Robin
    Moore, Philip
    Donoghue, Dan J.
    Donoghue, Ann M.
    Ricke, Steven C.
    FEMS MICROBIOLOGY LETTERS, 2011, 316 (01) : 7 - 15
  • [26] A microfluidic droplet digital PCR for simultaneous detection of pathogenic Escherichia coli O157 and Listeria monocytogenes
    Bian, Xiaojun
    Jing, Fengxiang
    Li, Gang
    Fan, Xiaoyun
    Jia, Chunping
    Zhou, Hongbo
    Jin, Qinghui
    Zhao, Jianlong
    BIOSENSORS & BIOELECTRONICS, 2015, 74 : 770 - 777
  • [27] Multiplex PCR for simultaneous identification of E-coli O157: H7, Salmonella spp. and L-monocytogenes in food
    Nguyen, Thuy Trang
    Van Giau, Vo
    Vo, Tuong Kha
    3 BIOTECH, 2016, 6
  • [28] Development of duplex PCR-ELISA for simultaneous detection of Salmonella spp. and Escherichia coli O157: H7 in food
    Hu, Jinqiang
    Huang, Runna
    Wang, Yi
    Wei, Xiangke
    Wang, Zhangcun
    Geng, Yao
    Jing, Jianzhou
    Gao, Hui
    Sun, Xincheng
    Dong, Caiwen
    Jiang, Chunpeng
    JOURNAL OF MICROBIOLOGICAL METHODS, 2018, 154 : 127 - 133
  • [29] MULTIPLEX PCR FOR THE DETECTION OF CAMPYLOBACTER SPP. AND SALMONELLA SPP. IN CHICKEN MEAT
    Alves, Juliane
    Marques, Viviani Vieira
    Protasio Pereira, Luiz Filipe
    Hirooka, Elisa Yoko
    Rocha Moreira De Oliveira, Tereza Cristina
    JOURNAL OF FOOD SAFETY, 2012, 32 (03) : 345 - 350
  • [30] Multiplex PCR and DNA array for the detection of Bacillus cereus, Staphylococcus aureus, Listeria monocytogenes, Escherichia coli O157:H7, and Salmonella spp. targeting virulence-related genes
    Thapa, Shree Prasad
    Han, Ah Reum
    Cho, Jun Mo
    Hur, Jang Hyun
    ANNALS OF MICROBIOLOGY, 2013, 63 (02) : 725 - 731