VOLTAMMETRIC AND AMPEROMETRIC DETERMINATION OF DOXORUBICIN USING CARBON PASTE ELECTRODES

被引:36
作者
Jemelkova, Zuzana [1 ]
Zima, Jiri [1 ]
Barek, Jiri [1 ]
机构
[1] Charles Univ Prague, Fac Sci, Dept Analyt Chem, UNESCO Lab Environm Electrochem, Prague 12843 2, Czech Republic
关键词
Doxorubicin; Carbon paste electrode; Direct current voltammetry; Differential pulse voltammetry; HPLC with amperometric detection; PERFORMANCE LIQUID-CHROMATOGRAPHY; FLOW-INJECTION ANALYSIS; MERCURY-ELECTRODE; ELECTROCHEMICAL PROPERTIES; HUMAN-PLASMA; RAT PLASMA; ADRIAMYCIN; URINE; METABOLITES; PRECONCENTRATION;
D O I
10.1135/cccc2009081
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Direct current voltammetric (DCV) and differential pulse voltammetric (DPV) determination of antineoplastic agent doxorubicin (DOX) at a carbon paste electrode (CPE) was developed. Britton-Robinson buffer (pH 7.0) was used as a supporting electrolyte. The limits of detection are 8 x 10(-7) mol l(-1) (DCV) and 6 x 10(-8) mol l(-1) (DPV). The accumulation of DOX at the electrode surface was used to decrease the limits of detection down to 2.2 x 10(-7) mol l(-1) for adsorptive stripping DC voltammetry (DCAdSV) and 2.8 x 10(-9) mol l(-1) for adsorptive stripping differential pulse voltammetry (DPAdSV) at CPE. The results of the voltammetric methods were utilized for the development of a new determination of doxorubicin using HPLC with amperometric detection on CPE based on spherical microparticles of glassy carbon in a wall-jet configuration. A column with chemically bonded C18 stationary phase and a mobile phase containing 0.01 M phosphate buffer (pH 5.0)-methanol 25: 75 (v/v) were used. The limit of detection is 4 x 10(-7) mol l(-1) (HPLC with electrochemical detection (ED)).
引用
收藏
页码:1503 / 1515
页数:13
相关论文
共 35 条
[1]   Adriblastina-single stranded DNA interaction with statistical analysis [J].
Abd El-Hady, D ;
Abdel-Hamid, MI ;
Seliem, MM ;
El-Maali, NA .
TALANTA, 2005, 66 (05) :1207-1218
[2]  
Abd El-Hady D, 2004, ARCH PHARM RES, V27, P1161
[3]   Simultaneous quantification of doxorubicin, lorazepam, metoclopramide, ondansetron, and ranitidine in mixtures by liquid chromatography-tandem mass spectrometry [J].
Abdel-Hamid, ME ;
Sharma, D .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2004, 27 (04) :641-660
[4]   High-performance liquid chromatographic validated assay of doxorubicin in rat plasma and tissues [J].
Alvarez-Cedrón, L ;
Sayalero, ML ;
Lanao, JM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 721 (02) :271-278
[5]   ADRIAMYCIN, 14-HYDROXYDAUNOMYCIN, A NEW ANTITUMOR ANTIBIOTIC FROM S-PEUCETIUS VAR CAESIUS [J].
ARCAMONE, F ;
CASSINEL.G ;
FANTINI, G ;
GREIN, A ;
OREZZI, P ;
POL, C ;
SPALLA, C .
BIOTECHNOLOGY AND BIOENGINEERING, 1969, 11 (06) :1101-&
[6]   Quantification of doxorubicin and metabolites in rat plasma and small volume tissue samples by liquid chromatography/electrospray tandem mass spectroscopy [J].
Arnold, RD ;
Slack, JE ;
Straubinger, RM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (02) :141-152
[7]   ELECTROCHEMICAL-BEHAVIOR OF ADRIAMYCIN AT CARBON PASTE ELECTRODES [J].
BALDWIN, RP ;
PACKETT, D ;
WOODCOCK, TM .
ANALYTICAL CHEMISTRY, 1981, 53 (03) :540-542
[8]   Study of voltammetric determination of carcinogenic 1-nitropyrene and 1-aminopyrene using a glassy carbon paste electrode [J].
Barek, J ;
Muck, A ;
Wang, J ;
Zima, J .
SENSORS, 2004, 4 (05) :47-57
[9]   Nontraditional electrode materials in environmental analysis of biologically active organic compounds [J].
Barek, Jiri ;
Fischer, Jan ;
Navratil, Tomas ;
Peckova, Karolina ;
Yosypchuk, Bogdan ;
Zima, Jiri .
ELECTROANALYSIS, 2007, 19 (19-20) :2003-2014
[10]   ELECTROCHEMICAL DETERMINATION OF ADRIAMYCIN COMPOUNDS IN URINE BY PRE-CONCENTRATION AT CARBON PASTE ELECTRODES [J].
CHANEY, EN ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1982, 54 (14) :2556-2560