Multiwalled Carbon Nanotubes/Nanofibrillar Cellulose/Nafion Composite-Modified Tetrahedral Amorphous Carbon Electrodes for Selective Dopamine Detection

被引:36
作者
Durairaj, Vasuki [1 ]
Wester, Niklas [1 ]
Etula, Jarkko [1 ]
Laurila, Tomi [3 ]
Lehtonen, Janika [2 ]
Rojas, Orlando J. [2 ]
Pahimanolis, Nikolaos [4 ]
Koskinen, Jari [1 ]
机构
[1] Aalto Univ, Dept Chem & Mat Sci, Sch Chem Engn, POB 16100, Aalto 00076, Finland
[2] Aalto Univ, Dept Bioprod & Biosyst, Sch Chem Engn, POB 16100, Aalto 00076, Finland
[3] Aalto Univ, Sch Elect Engn, Dept Elect Engn & Automat, POB 13500, Aalto 00076, Finland
[4] Betulium Oy, Tekniikantie 2, FI-02150 Espoo, Finland
基金
芬兰科学院;
关键词
ELECTROCHEMICAL DETECTION; ASCORBIC-ACID; URIC-ACID; FILMS; NANOCELLULOSE; NANOTUBES; NANOCOMPOSITE; NANOFIBRILS; GRAPHENE; NAFION;
D O I
10.1021/acs.jpcc.9b05537
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We introduce a composite membrane comprised of multiwalled carbon nanotubes (MWCNTs) dispersed in a matrix of sulfated nanofibrillar cellulose (SNFC) and Nafion. The high negative charge densities of the SNFC and Nafion ionomers enhance the cationic selectivity of the composite. The composite is characterized by scanning electron (SEM) and transmission electron (TEM) microscopies as well as Fourier transform infrared (FTIR) and Raman spectroscopies. Tetrahedral amorphous carbon (ta-C) electrodes modified with the composite are investigated as potential dopamine (DA) electrochemical sensors. The composite-modified electrodes show significant selectivity and sensitivity toward DA in the presence of ascorbic acid (AA) and uric acid (UA) in physiologically relevant concentrations. A linear dopamine detection range of 0.05-100 mu M with detection limits of 65 nM in PBS and 107 nM in interferent solution was determined using 100 mV/s cyclic voltammetry (CV) measurements. These results highlight the potential of the composite membrane for in vivo detection of neurotransmitters.
引用
收藏
页码:24826 / 24836
页数:11
相关论文
共 50 条
  • [41] Highly Selective and Sensitive Detection of Dopamine in the Presence of Excessive Ascorbic Acid Using Electrodes Modified with C60-Functionalized Multiwalled Carbon Nanotube Films
    Zhu, Huarui
    Wu, Wei
    Zhang, Hua
    Fan, Louzhen
    Yang, Shihe
    ELECTROANALYSIS, 2009, 21 (24) : 2660 - 2666
  • [42] Simultaneous determination of dopamine and uric acid on nafion/sodium dodecylbenzenesulfonate composite film modified glassy carbon electrode
    Cao, Xiaomei
    Luo, Liqiang
    Ding, Yaping
    Yu, Dawang
    Gao, Yibo
    Meng, Ye
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (09) : 1603 - 1608
  • [43] Highly selective dopamine electrochemical sensor based on electrochemically pretreated graphite and nafion composite modified screen printed carbon electrode
    Ku, Shuhao
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2013, 411 : 182 - 186
  • [44] Highly Selective Determination of Dopamine in the Presence of Ascorbic Acid and Serotonin at Glassy Carbon Electrodes Modified with Carbon Nanotubes Dispersed in Polyethylenimine
    Rodriguez, Marcela C.
    Rubianes, Maria D.
    Rivas, Gustavo A.
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (11) : 6003 - 6009
  • [45] Iron Oxide Nanoparticle and Multiwalled Carbon Nanotube Modified Glassy Carbon Electrodes. Application to Levodopa Detection
    Baiao, Vanessa
    Tome, Luciana I. N.
    Brett, Christopher M. A.
    ELECTROANALYSIS, 2018, 30 (07) : 1342 - 1348
  • [46] Enhancing dopamine detection using a glassy carbon electrode modified with MWCNTs, quercetin, and Nafion®
    Chen, Po-Yen
    Vittal, R.
    Nien, Po-Chin
    Ho, Kuo-Chuan
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (12) : 3504 - 3509
  • [47] Highly sensitive and selective detection of dopamine using overoxidized polypyrrole/sodium dodecyl sulfate-modified carbon nanotube electrodes
    Eom, Gayoung
    Oh, Chaerin
    Moon, Jeong
    Kim, Hyojung
    Kim, Mi Kyung
    Kim, Kiup
    Seo, Ji-Won
    Kang, Taejoon
    Lee, Hyunjoo J.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 848
  • [48] Selective detection of morphine in the presence of paracetamol with anodically pretreated dual layer Ti/tetrahedral amorphous carbon electrodes
    Wester, Niklas
    Etula, Jarkko
    Lilius, Tuomas
    Sainio, Sami
    Laurila, Tomi
    Koskinen, Jari
    ELECTROCHEMISTRY COMMUNICATIONS, 2018, 86 : 166 - 170
  • [49] Carbon nanotubes paste electrodes modified with a melanic polymer: Analytical applications for the sensitive and selective quantification of dopamine
    Rubianes, Maria D.
    Sanchez Arribas, Alberto
    Bermejo, Esperanza
    Chicharro, Manuel
    Zapardiel, Antonio
    Rivas, Gustavo
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 144 (01) : 274 - 279
  • [50] Electrochemical selective detection of dopamine on microbial carbohydrate-doped multiwall carbon nanotube-modified electrodes
    Jin, Joon-Hyung
    Cho, Eunae
    Jung, Seunho
    BIOTECHNOLOGY LETTERS, 2010, 32 (03) : 413 - 419