Friction and wear behaviour of cp Ti and Ti6A14V following nitric acid passivation

被引:49
作者
Masmoudi, M.
Assoul, M.
Wery, M.
Abdelhedi, R.
El Halouani, F.
Monteil, G.
机构
[1] Ecole Natl Ingenieurs Sfax, Unite Phys & Mecan Mat, LASEM, Sfax 3038, Tunisia
[2] Ecole Natl Ingenieurs Sfax, Unite Rech Electrochim & Environm, Sfax 3038, Tunisia
[3] LMS, F-25030 Besancon, France
[4] LCMI, F-25030 Besancon, France
关键词
titanium; nitric acid passivation; friction and wear; corrosion;
D O I
10.1016/j.apsusc.2006.04.047
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Nitric acid passivation increases the thickness of the TiO2 passive film formed at the cp Ti and Ti(6)Al4V surface. The TiO2 oxide, which has a lubricating nature, reduces the wear rate. A linear ball-on-disc friction test has been carried out at room temperature in ambient air, NaCl 3% and Ringer's solutions, with a sliding velocity of 4 mm s(-1) and a normal load of 1 N. Friction coefficient curves obtained from ball-on-disc wear test, as well as following the optical microscopy observation of ball trace, indicated the presence of periodic phenomenon. One period can be divided into four stages. This can be clearly seen for cp Ti (accommodation stage, creation of wear particles, adherence of particles layer on the alumina ball and ejection of this layer). In order to confirm this observation and understand the chemical interfacial phenomena, open circuit potential (OCP) measurements were carried out in the same time of friction tests. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:2237 / 2243
页数:7
相关论文
共 29 条
[1]   WEAR-CORROSION MECHANISM OF STAINLESS-STEEL IN CHLORIDE MEDIA [J].
ABDELKADER, H ;
ELRAGHY, SM .
CORROSION SCIENCE, 1986, 26 (08) :647-653
[2]  
[Anonymous], 2018, ORAL IMPLANTOLOGY, V11, P185
[3]   WEAR-ACCELERATED CORROSION OF TI-6AL-4V AND NITROGEN-ION-IMPLANTED TI-6AL-4V - MECHANISMS AND INFLUENCE OF FIXED-STRESS MAGNITUDE [J].
BUCHANAN, RA ;
RIGNEY, ED ;
WILLIAMS, JM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (03) :367-377
[4]   Electrochemical characterization of cast titanium alloys [J].
Cai, Z ;
Shafer, T ;
Watanabe, I ;
Nunn, ME ;
Okabe, T .
BIOMATERIALS, 2003, 24 (02) :213-218
[5]   A study of the potentials achieved during mechanical abrasion and the repassivation rate of titanium and Ti6Al4V in inorganic buffer solutions and bovine serum [J].
Contu, F ;
Elsener, B ;
Böhni, H .
ELECTROCHIMICA ACTA, 2004, 50 (01) :33-41
[6]   Corrosion behaviour of titanium in biofluids containing H2O2 studied by electrochemical impedance spectroscopy [J].
Fonseca, C ;
Barbosa, MA .
CORROSION SCIENCE, 2001, 43 (03) :547-559
[7]   CHARACTERIZATION OF SURFACE-FILM FORMED ON TITANIUM IN ELECTROLYTE USING XPS [J].
HANAWA, T ;
OTA, M .
APPLIED SURFACE SCIENCE, 1992, 55 (04) :269-276
[8]   Characterisation of titanium oxide film grown in 0.9% NaCl at different sweep rates [J].
Huang, YZ ;
Blackwood, DJ .
ELECTROCHIMICA ACTA, 2005, 51 (06) :1099-1107
[9]  
HUTCHINGS IM, 1992, TRIBOLOGY FRICTION W, P4
[10]   Wear resistance of plasma immersion ion implanted Ti6Al4V [J].
Johns, SM ;
Bell, T ;
Samandi, M ;
Collins, GA .
SURFACE & COATINGS TECHNOLOGY, 1996, 85 (1-2) :7-14