Immediate loading of dental implants supporting fixed partial dentures in the posterior mandible: A randomized controlled split-mouth study - Machined versus titanium oxide implant surface

被引:0
|
作者
Schincaglia, Gian Pietro [1 ]
Marzola, Riccardo [1 ]
Scapoli, Chiara [1 ]
Scotti, Roberto [1 ]
机构
[1] Univ Bologna, Alma Mater Studiorum, Dept Prosthodont, Sch Dent, Bologna, Italy
关键词
dental implants; immediate loading; randomized controlled trials;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: A split-mouth study was conducted to compare dental implants with either machined or titanium oxide (TiO) surfaces immediately loaded with fixed partial dentures in the posterior mandible. Materials and Methods: Ten patients with bilateral partial edentulism in the posterior mandible received 42 implants; 20 on the test (TiO) and 22 on the control (machined) side. The implants were loaded within 24 hours postsurgery. At implant placement the maximum insertion torque (IT) was recorded. Implant stability quotient (ISQ) was also evaluated at baseline (day 0) and 1, 2, 4, 12, 24, and 52 weeks following implant placement. The radiographic bone level (RBL) change was measured on periapical radiographs at baseline and 12 months after loading. Means for the 2 groups were compared by paired t test. Results: The overall implant success rate was 95%. No implants were lost in the test group; 2 failed in the control group. The difference between the groups in RBL change after 1 year of function was not statistically significant (P =.224). However, average RBL change for machined implants in distal positions was significantly higher than for TiO surface implants in the same position (post-hoc comparison; P =.048). ISQ and peak IT values did not differ between the groups (P =.414 and P =.762, respectively). The high IT necessary to insert the implants did not seem to affect the RBL change (P =.203). Conclusions: No significant difference was observed between machined and TiO implant surface in terms of RBL change or ISQ, although TiO implants may provide a lower RBL change compared to machined implants when utilized in the distal position. Immediate loading of implants using fixed partial dentures in posterior mandible may be considered as a treatment option if implants are inserted with IT >= 20 Ncm and ISQ >= 60 into nonaugmented bone and loaded with light centric occlusal contact.
引用
收藏
页码:35 / 46
页数:12
相关论文
共 33 条
  • [1] A 36-Month Randomized Controlled Split-Mouth Trial Comparing Immediately Loaded Titanium Oxide-Anodized and Machined Implants Supporting Fixed Partial Dentures in the Posterior Mandible
    Fung, Karen
    Marzola, Riccardo
    Scotti, Roberto
    Tadinada, Aditya
    Schincaglia, Gian Pietro
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (03) : 631 - 638
  • [2] Immediate versus conventions loading of variable-thread tapered implants supporting three- to four-unit fixed partial dentures in he posterior maxilla: 3-year results of a split-mouth randomised controlled trial
    Daher, Fadi I.
    Abi-Aad, Habib L.
    Dimassi, Hani I.
    Cordioli, Giampiero
    Majzoub, Zeina A. K.
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2019, 12 (04) : 449 - 466
  • [3] Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial
    Torroella-Saura, Gerard
    Mareque-Bueno, Javier
    Cabratosa-Termes, Josep
    Hernandez-Alfaro, Federico
    Ferres-Padro, Eduard
    Luis Calvo-Guirado, Jose
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (03) : 240 - 244
  • [4] Immediate vs conventional loading of variable-thread tapered implants supporting three- to four-unit fixed partial dentures in the posterior maxilla: 1-year interim results of a split-mouth randomised controlled trial
    Abi-Aad, Habib
    Daher, Fadi
    Dimassi, Hani
    Cordioli, Giampiero
    Majzoub, Zeina
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2018, 11 (03) : 337 - 350
  • [5] Comparative Study of Immediate Loading on Short Dental Implants and Conventional Dental Implants in the Posterior Mandible: A Randomized Clinical Trial
    Weerapong, Kritsada
    Sirimongkolwattana, Siripong
    Sastraruji, Thanapat
    Khongkhunthian, Pathawee
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (01) : 141 - 149
  • [6] Factors Affecting Implant Stability Quotients at Immediately and Conventionally Loaded Implants in the Posterior Maxilla: A Split-Mouth Randomized Controlled Trial
    Daher, Fadi I.
    Abi-Aad, Habib L.
    Dimassi, Hani I.
    Baba, Nadim Z.
    Majzoub, Zeina AK.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (07): : 590 - 603
  • [7] Immediate vs. delayed loading in the posterior mandible: a split-mouth study with up to 15years of follow-up
    Romanos, Georgios E.
    Aydin, Erhan
    Locher, Kathrin
    Nentwig, Georg-Hubertus
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (02) : E74 - E79
  • [8] Tapered Screw Implants With Different Machined Neck Designs: A 3-Year Split-Mouth Randomized Controlled Prospective Study
    Beretta, Mario
    Maiorana, Carlo
    Cortinovis, Ivan
    Poli, Pier Paolo
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (05) : 416 - 420
  • [9] Nanostructured Calcium-Incorporated Surface Compared to Machined and SLA Dental Implants-A Split-Mouth Randomized Case/Double-Control Histological Human Study
    Makary, Christian
    Menhall, Abdallah
    Lahoud, Pierre
    An, Hyun-Wook
    Park, Kwang-Bum
    Traini, Tonino
    NANOMATERIALS, 2023, 13 (02)
  • [10] Immediate/early function with tapered implants supporting maxillary and mandibular posterior fixed partial dentures: Preliminary results of a prospective multicenter study
    Achilli, Antonio
    Tura, Flavio
    Euwe, Egon
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (06): : S52 - S58