The 2-minute walk test is not a valid method to determine aerobic capacity in persons with Multiple Sclerosis

被引:7
作者
Beckerman, Heleen [1 ]
Heine, Martin [1 ,2 ,3 ,4 ]
van den Akker, Lizanne E. [1 ]
de Groot, Vincent [1 ]
机构
[1] Vrije Univ, Amsterdam Univ Med Ctr, MS Ctr Amsterdam, Amsterdam Publ Hlth Res Inst,Dept Rehabil Med, POB 7057, NL-1007 MB Amsterdam, Netherlands
[2] Univ Med Ctr Utrecht, Brain Ctr Rudolf Magnus, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Ctr Excellence Rehabil Med, Utrecht, Netherlands
[4] Rehabil Ctr De Hoogstraat, Utrecht, Netherlands
关键词
Exercise capacity; Multiple Sclerosis; 2 minute walk test; criterion validity; EXERCISE CAPACITY; 6-MINUTE; QUALITY; FATIGUE; ADULTS; TOOLS;
D O I
10.3233/NRE-192792
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Walking tests, like the 2-minute fast walk test, are simple, inexpensive performance-based tests, and therefore seem attractive to estimate the aerobic fitness in people with chronic diseases. OBJECTIVE: To determine the criterion validity of the 2-minute fast walk test for estimating aerobic capacity in patients with Multiple Sclerosis (MS), by comparing it with the peak oxygen uptake (VO2peak in mL/kg/min) as measured by Cardiopulmonary Exercise Testing (CPET) on a cycle ergometer. METHODS: The 2min fast walk test was performed on a marked indoor trajectory, using a static start protocol. Aerobic capacity (VO2peak, in mL/kg/min) was derived from CPET on a cycle ergometer. Criterion validity was tested by means of Pearson's correlation coefficient and should be at least 0.70 for a good criterion validity of the 2min walk test. Linear regression analysis was applied to more precisely estimate VO2peak. RESULTS: In total 141 people with severe MS-related fatigue (mean age 47.0 years (range 23-68 years), 73% women, median disease duration 7.8 years (range 0.3 -28.7 years)) performed both tests. The distance walked in two minutes ranged from 52.0 to 290.0 m (mean 175.1 m, sd 44.9 m), while the VO2peak varied between 11.31 and 40.28 mL/kg/min (mean 22.52 mL/kg/min, sd 6.07 mL/kg/min). The correlation between the 2min walk test and VO2peak was 0.441 (95% CI: 0.309-0.570). The absolute residual error in estimated VO2peak was 5.47 mL/kg/min. CONCLUSIONS: Due to the poor correlation found between the 2min walk test and VO2peak, the 2-min walk test cannot be recommended as a valid alternative for estimating aerobic capacity in persons with MS.
引用
收藏
页码:239 / 245
页数:7
相关论文
共 43 条
[21]   Aerobic Capacity in Persons with Multiple Sclerosis: A Systematic Review and Meta-Analysis [J].
Martin Langeskov-Christensen ;
Martin Heine ;
Gert Kwakkel ;
Ulrik Dalgas .
Sports Medicine, 2015, 45 :905-923
[22]   Six-Minute Walk Test Performance in Persons With Multiple Sclerosis While Using Passive or Powered Ankle-Foot Orthoses [J].
Boes, Morgan K. ;
Bollaert, Rachel E. ;
Kesler, Richard M. ;
Learmonth, Yvonne C. ;
Islam, Mazharul ;
Petrucci, Matthew N. ;
Motl, Robert W. ;
Hsiao-Wecksler, Elizabeth T. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2018, 99 (03) :484-490
[23]   The figure-of-eight walk test is a reliable and valid test for assessing walking skill in people with multiple sclerosis [J].
Soke, Fatih ;
Demirkaya, Seref ;
Gulsen, Cagri ;
Yavuz, Numan ;
Karakoc, Selda ;
Gulsen, Elvan Ozcan ;
Yilmaz, Oznur ;
Kocer, Bilge ;
Aydin, Fatma Kurtulus ;
Yucesan, Canan .
MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2022, 67
[24]   The Two-Minute Walk Test in Persons with Multiple Sclerosis: Correlations of Cadence with Free-Living Walking Do Not Support Ecological Validity [J].
Karle, Viktoria ;
Hartung, Verena ;
Ivanovska, Keti ;
Maeurer, Mathias ;
Flachenecker, Peter ;
Pfeifer, Klaus ;
Tallner, Alexander .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (23) :1-11
[25]   Evaluation of Prolonged Walking in Persons with Multiple Sclerosis: Reliability of the Spatio-Temporal Walking Variables during the 6-Minute Walk Test [J].
Hadouiri, Nawale ;
Monnet, Elisabeth ;
Gouelle, Arnaud ;
Decavel, Pierre ;
Sagawa, Yoshimasa .
SENSORS, 2021, 21 (09)
[26]   The reliability and validity of the Figure of 8 walk test in mildly disabled persons with multiple sclerosis [J].
Kirmaci, Zekiye Ipek Katirci ;
Adiguzel, Hatice ;
Erel, Suat ;
Inanc, Yilmaz ;
Berktas, Deniz Tuncel .
MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2023, 69
[27]   Six-Minute Walk Test as a Measure of Walking Capacity in Ambulatory Individuals With Amyotrophic Lateral Sclerosis [J].
Sanjak, Mohammed ;
Langford, Velma ;
Holsten, Scott ;
Rozario, Nigel ;
Patterson, Charity G. Moore ;
Bravver, Elena ;
Bockenek, William L. ;
Brooks, Benjamin R. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2017, 98 (11) :2301-2307
[28]   The aerobic capacity - fatigue relationship in persons with Multiple Sclerosis is not reproducible in a pooled analysis of two randomized controlled trials [J].
Wolf, Florian ;
Rademacher, Annette ;
Joisten, Niklas ;
Proschinger, Sebastian ;
Schlagheck, Marit Lea ;
Bloch, Wilhelm ;
Gonzenbach, Roman ;
Kool, Jan ;
Bansi, Jens ;
Zimmer, Philipp .
MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2022, 58
[29]   A Two-Minute Walking Test With a Smartphone App for Persons With Multiple Sclerosis: Validation Study [J].
van Oirschot, Pim ;
Heerings, Marco ;
Wendrich, Karine ;
den Teuling, Bram ;
Dorssers, Frank ;
van Ee, Rene ;
Martens, Marijn Bart ;
Jongen, Peter Joseph .
JMIR FORMATIVE RESEARCH, 2021, 5 (11)
[30]   Six-Minute Walk as a Measure of Walking Capacity and Endurance in Patients With Pediatric-Onset Multiple Sclerosis [J].
Brenton, J. Nicholas ;
Florenzo, Brian ;
Koshiya, Hitoshi ;
Min, Seulgi ;
Woolbright, Emma ;
Coleman, Rachael ;
Chen, Shanshan ;
Goldman, Myla .
NEUROLOGY, 2022, 99 (19) :E2161-E2170