Results of a Prospective Study to Evaluate the Impact of Point-of-Care Ultrasound in the Enhancement of Gastrointestinal Bleeding Risk Scores

被引:1
|
作者
Tung Chen, Yale [1 ,3 ]
Blancas Gomez-Casero, Rafael [3 ,4 ]
Quintana Diaz, Manuel [2 ]
Villen Villegas, Tomas [1 ,5 ]
Cobo Mora, Julio [1 ]
Carballo Cardona, Cesar [1 ]
机构
[1] Hosp Univ La Paz, Dept Emergency Med, Paseo Castellana 261, Madrid 28046, Spain
[2] Hosp Univ La Paz, Crit Care, Madrid, Spain
[3] Univ Alfonso X El Sabio, Dept Med, Madrid, Spain
[4] Hosp Univ Tajo, Dept Crit Care, Aranjuez, Spain
[5] Univ Francisco Vitoria, Dept Med, Madrid, Spain
关键词
gastrointestinal bleeding; inferior vena cava; passive leg-raising test; point-of-care ultrasound; systolic obliteration of the left ventricle; velocity time integral; FLUID RESPONSIVENESS; EARLY DISCHARGE; FLOW;
D O I
10.1002/jum.15101
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives Gastrointestinal (GI) bleeding is a common illness seen in the emergency department. The prognosis varies from self-limited to potentially life threatening. Currently available GI bleeding risk scores have only a modest predictive value, limiting their wide implementation. The aim of this study was to assess the association and capability of point-of-care ultrasound (POCUS) used by emergency physicians to improve common GI bleeding scores for predicting complications and long-term outcomes of patients with GI bleeding, which to our knowledge have never been studied. Methods Between August 2015 and April 2017, 203 hemodynamically stable patients with acute GI bleeding admitted to the emergency department were prospectively investigated. Using ultrasound, we measured the inferior vena cava diameter, cardiac output with surrogate markers such as the velocity time integral before and after the passive leg-raising test, and the presence of systolic obliteration of the left ventricle. The Rockall and Glasgow-Blatchford scores were calculated for patients with upper GI bleeding and the Velayos score for lower GI bleeding. The patients had follow-up during hospitalization and 30 days later to assess for early and late adverse events (AEs). Then we integrated the ultrasound findings of hypovolemia into the GI bleeding scores, assessing the capability to detect AEs. Results In our cohort, patients with upper GI bleeding who showed left ventricle kissing walls had a worse evolution, with a greater presence of late AEs (odds ratio [OR], 3.8; 95% confidence interval [CI], 1.32-10.96; P = .01). Patients with lower GI bleeding who showed a collapse of the inferior vena cava (>50%) after passive leg raising had a greater presence of early AEs (OR, 3.6; 95% CI, 1.46-9.00; P = .004). The predictive performance of the Rockall score (receiver operating characteristic analysis: area under the curve [AUC], 77.6%; 95% CI, 66.3%-88.8%) increased with POCUS (AUC, 80.3%; 95% CI, 69.5%-91.1%); that of the Glasgow-Blatchford score (AUC, 72.5%; 95% CI, 59.9%-85.2%) increased with POCUS (AUC, 73.2%; 95% CI, 61.1%-85.4%); and that of Velayos score (AUC, 55.7%; 95% CI, 42.5%-69.0%) also increased with POCUS (AUC, 72.2%; 95% CI, 61.1%-83.3%). Conclusions The use of POCUS in GI bleeding is feasible and enhances common GI bleeding risk scores, showing better predictive performance in detecting AEs.
引用
收藏
页码:279 / 287
页数:9
相关论文
共 50 条
  • [41] Point-of-Care Ultrasound for High-Risk Pregnancy Screening in Rural Nepal
    Ward, Rebecca E.
    Joe, Winston B.
    Jha, Saurabh
    Sherpa, Mingmar G.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2024, 21 (08) : 1235 - 1238
  • [42] Preoperative point-of-care ultrasound and its impact on arteriovenous fistula maturation outcomes
    Hossain, Sajjid
    Sharma, Amit
    Dubois, Luc
    DeRose, Guy
    Duncan, Audra
    Power, Adam H.
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (04) : 1157 - 1165
  • [43] ACCURACY OF POINT-OF-CARE ULTRASOUND IN DETECTING FRACTURES IN CHILDREN: A VALIDATION STUDY
    Caroselli, Costantino
    Raffaldi, Irene
    Norbedo, Stefania
    Parri, Niccolo
    Poma, Francesca
    Blaivas, Michael
    Zaccaria, Eleonora
    Dib, Giovanni
    Fiorentino, Romano
    Longo, Daniele
    Biban, Paolo
    Urbino, Antonio Francesco
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (01) : 68 - 75
  • [44] Evaluation of a short formation on the performance of point-of-care renal ultrasound performed by physicians without previous ultrasound skills: prospective observational study
    Javaudin F.
    Mounier F.
    Pes P.
    Arnaudet I.
    Vignaud F.
    Frampas E.
    Le Conte P.
    Critical Ultrasound Journal, 2017, 9 (1)
  • [45] Point-of-Care Ultrasound: Does it Affect Scores on Standardized Assessment Tests Used Within the Preclinical Curriculum?
    Liu, Rachel B.
    Suwondo, David N.
    Donroe, Joseph H.
    Encandela, John A.
    Weisenthal, Karrin S.
    Moore, Christopher L.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (02) : 433 - 440
  • [46] Impact of an epic-integrated point-of-care ultrasound workflow on ultrasound performance, compliance, and potential revenue
    Rong, Katie
    Chimileski, Brock
    Kaloudis, Paul
    Herbst, Meghan Kelly
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 49 : 233 - 239
  • [47] Impact of Emergency Medicine Point-of-Care Ultrasound on Radiology Ultrasound Volumes in a Single Pediatric Emergency Department
    Kaplan, Summer L.
    Chen, Aaron E.
    Rempell, Rachel G.
    Brown, Nafis
    Velez-Florez, Maria C.
    Khwaja, Asef
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (12) : 1555 - 1562
  • [48] Point-of-care ultrasound use in patients with cardiac arrest is associated prolonged cardiopulmonary resuscitation pauses: A prospective cohort study
    Clattenburg, Eben J.
    Wroe, Peter
    Brown, Stephen
    Gardner, Kevin
    Losonczy, Lia
    Singh, Amandeep
    Nagdev, Arun
    RESUSCITATION, 2018, 122 : 65 - 68
  • [49] Comparison of Three Point-of-Care Ultrasound Views and MRI Measurements for Optic Nerve Sheath Diameter: A Prospective Validity Study
    Raval, Ronak
    Shen, Jay
    Lau, Deon
    Ferguson, Nick
    Kelly, Thomas
    Daniels, Justin
    Dorotta, Ihab
    Ramsingh, Davinder
    NEUROCRITICAL CARE, 2020, 33 (01) : 173 - 181
  • [50] Comparison of Three Point-of-Care Ultrasound Views and MRI Measurements for Optic Nerve Sheath Diameter: A Prospective Validity Study
    Ronak Raval
    Jay Shen
    Deon Lau
    Nick Ferguson
    Thomas Kelly
    Justin Daniels
    Ihab Dorotta
    Davinder Ramsingh
    Neurocritical Care, 2020, 33 : 173 - 181