Coronary MR angiography - A clinical experience in Japan

被引:0
|
作者
Nitatori, T [1 ]
Yoshino, H [1 ]
Yokoyama, K [1 ]
Hachiya, J [1 ]
Ishikawa, K [1 ]
机构
[1] Kyorin Univ, Sch Med, Dept Radiol, Mitaka, Tokyo 1818611, Japan
关键词
MRI; MRA; coronary vessels; vascular studies;
D O I
10.1002/(SICI)1522-2586(199911)10:5<709::AID-JMRI14>3.0.CO;2-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance angiography (MRA) has been expected to provide a useful noninvasive means of assessing coronary artery disease as this disease continues to increase due to westernization of life style, Several Japanese investigators have assessed the diagnostic value of two-dimensional (2D) and 3D coronary MRA in clinical patients evaluated for ischemic heart disease. Almost all reports indicate a high correlation between findings on 2D MRA and findings on conventional coronary angiography (CAG) in patients with severe stenosis of proximal arteries. Row ever, in our study involving 153 patients with ischemic heart disease, 2D MRA tended to underestimate lesions in patients with moderate stenotic lesions. Furthermore, this method could not be applied successfully in approximately 15% of our patients due to difficulty with breath-holding. These findings indicate some of the limitations associated with breath-holding in the 2D method. Recently, several reports have described high diagnostic accuracy using respiratory-gated 3D MRA with navigator echo. Effective use of a suitable contrast agent with better spatial and time resolution and better image reconstruction methods will enable 3D MRA to serve a useful role, even in screening for coronary artery disease. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:709 / 712
页数:4
相关论文
共 50 条
  • [31] Coronary MR angiography: True FISP imaging improved by prolonging breath holds with preoxygenation in healthy volunteers
    McCarthy, RM
    Shea, SM
    Deshpande, VS
    Green, JD
    Pereles, FS
    Carr, JC
    Finn, JP
    Li, DB
    RADIOLOGY, 2003, 227 (01) : 283 - 288
  • [32] Improved MR coronary angiography with use of a new rapid clearance blood pool contrast agent in pigs
    Dirksen, MS
    Lamb, HJ
    Kunz, P
    Robert, P
    Corot, C
    de Roos, A
    RADIOLOGY, 2003, 227 (03) : 802 - 808
  • [33] Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography
    Goldfarb, JW
    Edelman, RR
    RADIOLOGY, 1998, 206 (03) : 830 - 834
  • [34] MR angiography of abdominal and peripheral arteries - Techniques and clinical applications
    Ekelund, L
    Sjoqvist, L
    Thuomas, KA
    Asberg, B
    ACTA RADIOLOGICA, 1996, 37 (01) : 3 - 13
  • [35] MR angiography of the intracranial vessels:: technical aspects and clinical applications
    Özsarlak, Ö
    Van Goethem, JW
    Maes, M
    Parizel, PM
    NEURORADIOLOGY, 2004, 46 (12) : 955 - 972
  • [36] MR angiography of the intracranial vessels: technical aspects and clinical applications
    Özkan Özsarlak
    Johan W. Van Goethem
    Menno Maes
    Paul M. Parizel
    Neuroradiology, 2004, 46 : 955 - 972
  • [37] Unenhanced MR angiography of the thoracic aorta:: Initial clinical evaluation
    Francois, Christopher J.
    Tuite, David
    Deshpande, Vibhas
    Jerecic, Renate
    Weale, Peter
    Carr, James C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) : 902 - 906
  • [38] Submillimeter 3D coronary MR angiography with real-time navigator correction in 107 patients with suspected coronary artery disease
    Sommer, T
    Hofer, U
    Hackenbroch, M
    Meyer, C
    Flacke, S
    Schmiedel, A
    Schmitz, C
    Thiemann, K
    Omran, H
    Schild, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (04): : 459 - 466
  • [39] FLOW VELOCITY QUANTIFICATION IN HUMAN CORONARY-ARTERIES WITH FAST, BREATH-HOLD MR-ANGIOGRAPHY
    EDELMAN, RR
    MANNING, WJ
    GERVINO, E
    LI, W
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 699 - 703
  • [40] Whole-body MR angiography: initial experience in imaging pediatric vasculopathy
    Hong, Terence S.
    Greer, Mary-Louise C.
    Grosse-Wortmann, Lars
    Yoo, Shi-Joon
    Babyn, Paul S.
    PEDIATRIC RADIOLOGY, 2011, 41 (06) : 769 - 778