THE ROLE OF DOSE-RATE ON RISK FROM INTERNALLY-DEPOSITED RADIONUCLIDES AND THE POTENTIAL NEED TO SEPARATE DOSE-RATE EFFECTIVENESS FACTOR (DREF) FROM THE DOSE AND DOSE-RATE EFFECTIVENESS FACTOR (DDREF)

被引:21
作者
Brooks, Antone L. [1 ]
Eberlein, P. Elis [1 ]
Couch, Lezlie A. [1 ]
Boecker, Bruce B. [2 ]
机构
[1] Washington State Univ Tri Cities, Richland, WA 99352 USA
[2] Lovelace Resp Res Inst, Albuquerque, NM 87110 USA
来源
HEALTH PHYSICS | 2009年 / 97卷 / 05期
关键词
dogs; dose; low; National Council on Radiation Protection and Measurements; FUSED CLAY PARTICLES; TRANSFORMATION IN-VITRO; IONIZING-RADIATION; ADAPTIVE RESPONSE; INHALED Y-90; LUNG-CANCER; BEAGLE DOGS; GAMMA-IRRADIATION; INDUCTION; TOXICITY;
D O I
10.1097/HP.0b013e3181ac910e
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In 1980, National Council on Radiation Protection and Measurements suggested the term dose-rate effectiveness factor (DREF) to describe the reduction of effectiveness of protracted radiation in producing biological damage and risk. A nonlinear decrease in damage was also noted following low total doses. The International Commission on Radiological Protection therefore combined the influence of low dose and low dose-rate and assigned a single value of 2.0 for a dose and dose-rate effectiveness factor (DDREF) to be applied for estimating risk for both low total dose and low dose-rate exposures. This paper re-evaluates one extensive data set on inhaled radionuclides in dogs which suggests that there may be a need to separate these factors (DREF and DDREF) for larger protracted doses from internally-deposited radioactive materials. Extensive recent research on the mechanisms of action of both low dose and low dose-rate radiation exposure at the molecular, cellular, and animal level of biological organization suggest that the influence of protraction of radiation may be large and variable, due to adaptive and protective responses, following very low doses and dose-rate exposures. Important observations in this paper in dogs exposed by inhalation to beta-gamma emitting radionuclides include (1) discontinuities in the data sets as a function of both dose and dose-rate suggesting shifts in mechanisms of action following high doses from protracted exposure away from those postulated for cancer from low total doses; (2) no increase in non-neoplastic disease, cancer frequency, or life-shortening following low dose-rate exposures to high total lung doses (up to 25 Gy); (3) all dogs that received doses below 25 Gy were combined and a decrease in the frequency of lung cancer in these exposed animals relative to the controls was noted, while very large doses from all radionuclides studied resulted in very marked increases in lung cancer; (4) a significant increase in hemangiosarcoma in the heart and tracheobronchial lymph nodes was observed after very high doses; (5) in this paper the DREF for lung cancer in dogs relative to single acute radiation exposure was as high as 35; and (6) the amount of life-shortening increased per unit dose as a function of the half-life with Y-90 being eight times as effective per unit of dose as Sr-90. Such information suggests that there may be a need to assign different values for DDREF and DREF, especially in situations where there are large nonuniform total doses delivered by internally-deposited radionuclides. This is extremely important since the risk from radiation exposure from internally-deposited radionuclides in the lungs following nuclear fallout, accidents and terrorist activities may be much less than currently projected. Health Phys. 97(5):458-469; 2009
引用
收藏
页码:458 / 469
页数:12
相关论文
共 50 条
  • [31] VERTICAL TRANSPORT OF RADIOCESIUM IN SURFACE SOILS - MODEL IMPLEMENTATION AND DOSE-RATE COMPUTATION
    VELASCO, RH
    BELLI, M
    SANSONE, U
    MENEGON, S
    HEALTH PHYSICS, 1993, 64 (01): : 37 - 44
  • [32] Ultra-high dose-rate proton FLASH improves tumor control
    Shukla, Samriddhi
    Saha, Taniya
    Rama, Nihar
    Acharya, Anusha
    Le, Tien
    Bian, Fenghua
    Donovan, Johnny
    Tan, Lin Abigail
    Vatner, Ralph
    Kalinichenko, Vladimir
    Mascia, Anthony
    Perentesis, John P.
    Kalin, Tanya, V
    RADIOTHERAPY AND ONCOLOGY, 2023, 186
  • [33] Radiation adaptive response for constant dose-rate irradiation in high background radiation areas
    Bugala, Ernest
    Fornalski, Krzysztof Wojciech
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, : 29 - 44
  • [34] On the choice of methodology for evaluating dose-rate effects on radiation-related cancer risks
    Walsh, Linda
    Shore, Roy
    Azizova, Tamara V.
    Ruehm, Werner
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2021, 60 (03) : 493 - 500
  • [35] Dose-rate dependence of radiation induced interface trap density in silicon bipolar transistors
    Hjalmarson, H. P.
    Pease, R. L.
    Hembree, C. E.
    Van Ginhoven, R. M.
    Schultz, P. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 250 (1-2 SPEC. ISS.) : 269 - 273
  • [36] Dose-rate effects on adaptive response induced by tritiated water in human blood lymphocytes
    Petcu, I
    Bognar, G
    Koteles, GJ
    JOURNAL DE CHIMIE PHYSIQUE ET DE PHYSICO-CHIMIE BIOLOGIQUE, 1997, 94 (02) : 350 - 355
  • [37] Dose-Rate Effect on Proliferation Suppression in Human Cell Lines Continuously Exposed to γ Rays
    Magae, Junji
    Furukawa, Chiharu
    Ogata, Hiromitsu
    RADIATION RESEARCH, 2011, 176 (04) : 447 - 458
  • [38] EFFECT OF DOSE-RATE AND LENGTH OF STORAGE ON THE ESR SIGNAL STRENGTH IN IRRADIATED CHICKEN BONE
    GRAY, R
    STEVENSON, MH
    INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 1991, 26 (06) : 669 - 672
  • [39] Molecular and cellular effects of chronic low dose-rate ionizing radiation exposure in mice
    Osipov, Andreyan N.
    Multiple Stressors: A Challenge for the Future, 2007, : 429 - 438
  • [40] An absorbed-dose/dose-rate dependence for the alanine-EPR dosimetry system and its implications in high-dose ionizing radiation metrology
    Desrosiers, M. F.
    Publ, J. M.
    Cooper, S. L.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2008, 113 (02): : 79 - 95