Tumor dose enhancement by nanoparticles during high dose rate 192 Ir brachytherapy

被引:19
作者
Zabihzadeh, Mansour [1 ,2 ]
Arefian, Sahar [1 ]
机构
[1] Ahvaz Jundishapur Univ Med Sci, Sch Med, Dept Med Phys, Golestan Blvd, Ahvaz 6135733118, Iran
[2] Ahvaz Jundishapur Univ Med Sci, Golestan Hosp, Dept Radiotherapy & Radiat Oncol, Ahvaz 6135733118, Iran
关键词
Brachytherapy; dose enhancement factor; Monte Carlo simulation; nanoparticles; photoelectric interaction; GOLD NANOPARTICLES; MONTE-CARLO; VASCULAR-PERMEABILITY; IR-192; SOURCE; SOLID TUMOR; RADIATION; DOSIMETRY; RADIOTHERAPY; CANCER; FEASIBILITY;
D O I
10.4103/0973-1482.153668
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims and Objectives: The present study aims to evaluate and compare the dose enhancement factor (DEF) of tumor injected with different nanoparticles (NPs) around high dose rate (HDR) (192) Ir brachytherapy source. Materials and Methods: Monte Carlo calculations were performed with MCNPX code to determine the DEF caused by in tumor injected with (79) Au, (64) Gd, (26) Fe, and (22) Ti NPs during HDR (192) Ir brachytherapy. The uniform and non-uniform distribution of NPs within tumor was modeled with simple NPs-water mixture, and realistic nano-scale-lattice model. Furthermore, a margin of (79) Au and (64) Gd NPs was implemented around the tumor volume. Results: The increased dose caused by uniformly distributed (79) Au and (64) Gd NPs with 7, 18, and 30 mgr/gr concentrations was 4.7%, 11.8%, 19.4%, and 3.3%, 8.3%, and 18.6%, respectively. For non-uniform distribution, it was 0.4%, 1.2%, 1.9%, and 0.2%, 0.7%, and 1.2%, respectively. Increased tumor dose due to (26) Fe and (22) Ti was not significant. The peripheral-healthy tissue dose as margin with 2, 5, and 8.5 mgr/gr of (79) Au and (64) Gd increased by 1.3%, 3.6%, 6.5%, and 1.1%, 2.5%, and 4.2%, respectively. Increase the radial depth of tumor (from 1.5 to 5 cm) increase DEF (up to 22.3%). The nano-lattice model underestimated the DEF up to 4% and 3.6% for 79Au and (64) Gd NPs, respectively. Conclusion: Injecting of high-Z gold NPs into tumor increases the absorbed dose of tumor irradiated with (192) Ir HDR brachytherapy source. Size, geometry, concentration, and distribution model of NPs and tumor depth are crucial factors to accurately estimate the DEF.
引用
收藏
页码:752 / 759
页数:8
相关论文
共 50 条
  • [31] Effect of Gold Nanoparticles on Dose Enhancement in Brachytherapy Using a Polymer Gel Dosimeter
    Ko, Seung Young
    Kwon, Soo-Il
    Chun, Junchul
    Shin, Hyun Soo
    Chang, Sei Kyung
    Im, Jung Ho
    Lee, Jung Il
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 75 (05) : 415 - 423
  • [32] Feasibility of aponeurectomy in combination with perioperative 192Ir high dose rate brachytherapy for Dupuytren’s disease
    I. Frank Ciernik
    Philipp Goldschmidt
    Markus Wösle
    Jochen Winter
    Strahlentherapie und Onkologie, 2021, 197 : 903 - 908
  • [33] High dose rate interstitial 192-Ir brachytherapy for the treatment of a recurrent dermal vascular hamartoma in a horse
    Conti, F.
    Poujet, L.
    Delverdier, M.
    Lallemand, E. A.
    Benoit, J.
    EQUINE VETERINARY EDUCATION, 2022, 34 (08) : e337 - e343
  • [34] Experimental determination of Gd dose enhancement and Gd dose sparing by 192Ir brachytherapy source with Gafchromic EBT3 dosimeter
    Santibanez, M.
    Fuentealba, M.
    APPLIED RADIATION AND ISOTOPES, 2021, 175
  • [35] Determination of the tissue inhomogeneity correction in high dose rate Brachytherapy for Iridium-192 source
    Ravikumar, Barlanka
    Lakshminarayana, S.
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (01) : 27 - 31
  • [36] Characterization of microMOSFET detectors for in vivo dosimetry in high-dose-rate brachytherapy with 192Ir
    Ruiz-Arrebola, Samuel
    Fabregat-Borras, Rosa
    Rodriguez, Eduardo
    Fernandez-Montes, Manuel
    Perez-Macho, Mercedes
    Ferri, Maria
    Garcia, Ana
    Cardenal, Juan
    Pacheco, Maria T.
    Anchuelo, Javier
    Tornero-Lopez, Ana M.
    Prada, Pedro J.
    Guirado, Damian
    MEDICAL PHYSICS, 2020, 47 (05) : 2242 - 2253
  • [37] Dosimetry Parameters of the IRH10 192Ir High Dose Rate Brachytherapy Source
    Yi, Chul-Young
    Chun, Kook Jin
    Hah, Suck-Ho
    Kim, Hyun-Moon
    Lim, Chunil
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (04) : 485 - 492
  • [38] Design of a phantom for the quality control of high dose rate 192Ir source used in brachytherapy
    Ochoa, Ricardo
    Gomez, Fredy
    Ferreira, Ivaldo H.
    Gutt, Federico
    de Almeida, Carlos E.
    RADIOTHERAPY AND ONCOLOGY, 2007, 82 (02) : 222 - 228
  • [39] Comparative dosimetry of GammaMed Plus high-dose rate Ir-192 brachytherapy source
    Patel, N. P.
    Majumdar, B.
    Vijayan, V.
    JOURNAL OF MEDICAL PHYSICS, 2010, 35 (03) : 137 - 143
  • [40] HIGH-DOSE RATE (HDR) IR-192 BRACHYTHERAPY APPLICATION OF BASAL CELL CARCINOMA
    Basaric, Borko
    Petrovic, Borislava
    Teodorovic, Milan
    Baucal, Milutin
    Rutonjski, Laza
    Cudic, Ozren
    Djuran, Branislav
    Mitric-Askovic, Milana
    RAD 2015: THE THIRD INTERNATIONAL CONFERENCE ON RADIATION AND APPLICATIONS IN VARIOUS FIELDS OF RESEARCH, 2015, : 65 - 68