Tumor dose enhancement by nanoparticles during high dose rate 192 Ir brachytherapy

被引:18
|
作者
Zabihzadeh, Mansour [1 ,2 ]
Arefian, Sahar [1 ]
机构
[1] Ahvaz Jundishapur Univ Med Sci, Sch Med, Dept Med Phys, Golestan Blvd, Ahvaz 6135733118, Iran
[2] Ahvaz Jundishapur Univ Med Sci, Golestan Hosp, Dept Radiotherapy & Radiat Oncol, Ahvaz 6135733118, Iran
关键词
Brachytherapy; dose enhancement factor; Monte Carlo simulation; nanoparticles; photoelectric interaction; GOLD NANOPARTICLES; MONTE-CARLO; VASCULAR-PERMEABILITY; IR-192; SOURCE; SOLID TUMOR; RADIATION; DOSIMETRY; RADIOTHERAPY; CANCER; FEASIBILITY;
D O I
10.4103/0973-1482.153668
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims and Objectives: The present study aims to evaluate and compare the dose enhancement factor (DEF) of tumor injected with different nanoparticles (NPs) around high dose rate (HDR) (192) Ir brachytherapy source. Materials and Methods: Monte Carlo calculations were performed with MCNPX code to determine the DEF caused by in tumor injected with (79) Au, (64) Gd, (26) Fe, and (22) Ti NPs during HDR (192) Ir brachytherapy. The uniform and non-uniform distribution of NPs within tumor was modeled with simple NPs-water mixture, and realistic nano-scale-lattice model. Furthermore, a margin of (79) Au and (64) Gd NPs was implemented around the tumor volume. Results: The increased dose caused by uniformly distributed (79) Au and (64) Gd NPs with 7, 18, and 30 mgr/gr concentrations was 4.7%, 11.8%, 19.4%, and 3.3%, 8.3%, and 18.6%, respectively. For non-uniform distribution, it was 0.4%, 1.2%, 1.9%, and 0.2%, 0.7%, and 1.2%, respectively. Increased tumor dose due to (26) Fe and (22) Ti was not significant. The peripheral-healthy tissue dose as margin with 2, 5, and 8.5 mgr/gr of (79) Au and (64) Gd increased by 1.3%, 3.6%, 6.5%, and 1.1%, 2.5%, and 4.2%, respectively. Increase the radial depth of tumor (from 1.5 to 5 cm) increase DEF (up to 22.3%). The nano-lattice model underestimated the DEF up to 4% and 3.6% for 79Au and (64) Gd NPs, respectively. Conclusion: Injecting of high-Z gold NPs into tumor increases the absorbed dose of tumor irradiated with (192) Ir HDR brachytherapy source. Size, geometry, concentration, and distribution model of NPs and tumor depth are crucial factors to accurately estimate the DEF.
引用
收藏
页码:752 / 759
页数:8
相关论文
共 50 条
  • [21] A system for localization of high dose rate 192Ir source during brachytherapy treatment with silicon detectors
    Batic, Matej
    Burger, Janez
    Cindro, Vladimir
    Kramberger, Gregor
    Mandic, Igor
    Mikuz, Marko
    Studen, Andrej
    Zavrtanik, Marko
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3794 - +
  • [22] Tumor Control and Normal Tissue Complications in High-dose-rate Brachytherapy for Cervical Cancer Patients Using Ir-192 Radioactive Source
    Kaur, Gurpreet
    Garg, Pardeep
    Dangwal, Vinod Kumar
    Singh, Baltej
    Gaur, Garima
    Grover, Romikant
    Singh, Simrandeep
    Sharma, Rachana
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 363 - 369
  • [23] Dose volume assessment of high dose rate Ir-192 endobronchial implants
    Saw, CB
    Korb, LJ
    Pawlicki, T
    Wu, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (04): : 917 - 922
  • [24] Heterogeneity and scatter effects on Ir-192 brachytherapy dose distribution
    Osman, Alexander F. I.
    Maalej, Nabil
    Ul-Rahman, Khateeb
    Rahman, Wamied Abdel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (10): : 1210 - 1215
  • [25] Dose enhancement by various nanoparticles in prostate brachytherapy
    Mahdi Ghorbani
    Mahdi Bakhshabadi
    Alireza Golshan
    Courtney Knaup
    Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 431 - 440
  • [26] Film dosimetry calibration method for pulsed-dose-rate brachytherapy with an 192Ir source
    Schwob, Nathan
    Orion, Itzhak
    MEDICAL PHYSICS, 2007, 34 (05) : 1678 - 1683
  • [27] A comparison of the biological effective dose of 50-kV electronic brachytherapy with 192Ir high-dose-rate brachytherapy for vaginal cuff irradiation
    Rava, Paul
    Dvorak, Tomas
    Markelewicz, Robert J., Jr.
    Hiatt, Jessica R.
    Sternick, Edward S.
    MacAusland, Stephanie G.
    Huber, Kathryn
    Wazer, David E.
    Hepel, Jaroslaw T.
    BRACHYTHERAPY, 2012, 11 (05) : 402 - 407
  • [28] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Sadeghi, Mahdi
    Taghdiri, Fatemah
    Saidi, Pooneh
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (05) : 324 - 329
  • [29] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Mahdi Sadeghi
    Fatemah Taghdiri
    Pooneh Saidi
    Japanese Journal of Radiology, 2011, 29 : 324 - 329
  • [30] Effect of Gold Nanoparticles on Dose Enhancement in Brachytherapy Using a Polymer Gel Dosimeter
    Ko, Seung Young
    Kwon, Soo-Il
    Chun, Junchul
    Shin, Hyun Soo
    Chang, Sei Kyung
    Im, Jung Ho
    Lee, Jung Il
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 75 (05) : 415 - 423