Flow-modulated comprehensive two-dimensional gas chromatography combined with a vacuum ultraviolet detector for the analysis of complex mixtures

被引:35
|
作者
Zoccali, Mariosimone [1 ]
Schug, Kevin A. [2 ]
Walsh, Phillip [3 ]
Smuts, Jonathan [3 ]
Mondello, Luigi [1 ,4 ,5 ]
机构
[1] Univ Messina, Dipartimento Sci Chim Biol Farmaceut & Ambientali, Chromaleont Sr1, Viale Annunziata, I-98168 Messina, Italy
[2] Univ Texas Arlington, Dept Chem & Biochem, Arlington, TX 76019 USA
[3] VUV Analyt Inc, Cedar Pk, TX 78613 USA
[4] Univ Messina, Dipartimento Sci Chim Biol Farmaceut & Ambientali, Viale Annunziata, I-98168 Messina, Italy
[5] Univ Campus Biomed Rome, Via Alvaro del Portillo,21, I-00128 Rome, Italy
关键词
Flow modulation; Comprehensive two-dimensional gas chromatography; Vacuum ultraviolet detector; Method optimization; Pseudo-absolute quantification; MASS-SPECTROMETER; SPECTROSCOPY; GC;
D O I
10.1016/j.chroma.2017.03.073
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present paper is focused on the use of a vacuum ultraviolet absorption spectrometer (VUV) for gas chromatography (GC), within the context of flow modulated comprehensive two-dimensional gas chromatography (FM GC x GC). The features of the VUV detector were evaluated through the analysis of petrochemical and fatty acids samples. Besides responding in a predictable fashion via Beer's law principles, the detector provides additional spectroscopic information for qualitative analysis. Virtually all chemical species absorb and have unique gas phase absorption features in the 120-240 nm wavelength range monitored. The VUV detector can acquire up to 90 full range absorption spectra per second, allowing its coupling with comprehensive two-dimensional gas chromatography. This recent form of detection can address specific limitations related to mass spectrometry (e.g., identification of isobaric and isomeric species with very similar mass spectra or labile chemical compounds), and it is also able to deconvolute co-eluting peaks. Moreover, it is possible to exploit a pseudo-absolute quantitation of analytes based on pre-recorded absorption cross-sections for target analytes, without the need for traditional calibration. Using this and the other features of the detector, particular attention was devoted to the suitability of the FM GC x GC-VUV system toward qualitative and quantitative analysis of bio-diesel fuel and different kinds of fatty acids. Satisfactory results were obtained in terms of tailing factor (1.1), asymmetry factor (1.1), and similarity (average value 97%), for the FAMEs mixtures analysis. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 143
页数:9
相关论文
共 50 条
  • [1] Flow-modulated comprehensive two-dimensional gas chromatography with simultaneous flame ionization and quadrupole mass spectrometric detection
    Krupcik, Jan
    Gorovenko, Roman
    Spanik, Ivan
    Sandra, Pat
    Armstrong, Daniel W.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1280 : 104 - 111
  • [2] On the determination of a detector response enhancement factor for flow modulated comprehensive two-dimensional gas chromatography
    Krupcik, Jan
    Majek, Pavel
    Gorovenko, Roman
    Spanik, Ivan
    Sandra, Pat
    Armstrong, Daniel W.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1286 : 235 - 240
  • [3] Use of greatly-reduced gas flows in flow-modulated comprehensive two-dimensional gas chromatography-mass spectrometry
    Tranchida, Peter Q.
    Franchina, Flavio A.
    Dugo, Paola
    Mondello, Luigi
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1359 : 271 - 276
  • [4] Towards the determination of an equivalent standard column set between cryogenic and flow-modulated comprehensive two-dimensional gas chromatography
    Aloisi, Ivan
    Schena, Tiago
    Giocastro, Barbara
    Zoccali, Mariosimone
    Tranchida, Peter Q.
    Caramao, Elina Bastos
    Mondello, Luigi
    ANALYTICA CHIMICA ACTA, 2020, 1105 (231-236) : 231 - 236
  • [5] Flow-modulated comprehensive two-dimensional gas chromatography combined with time-of-flight mass spectrometry: use of hydrogen as a more sustainable alternative to helium
    Galletta, Micaela
    Zoccali, Mariosimone
    Jones, Nick
    Mondello, Luigi
    Tranchida, Peter Q.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (21) : 6371 - 6378
  • [6] Multilevel characterization of marine microbial biodegradation potentiality by means of flow-modulated comprehensive two-dimensional gas chromatography combined with a triple quadrupole mass spectrometer
    Zoccali, Mariosimone
    Cappello, Simone
    Mondello, Luigi
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1547 : 99 - 106
  • [7] Flow-modulated comprehensive two-dimensional gas chromatography combined with time-of-flight mass spectrometry: use of hydrogen as a more sustainable alternative to helium
    Micaela Galletta
    Mariosimone Zoccali
    Nick Jones
    Luigi Mondello
    Peter Q. Tranchida
    Analytical and Bioanalytical Chemistry, 2022, 414 : 6371 - 6378
  • [8] A Vacuum Ultraviolet Absorption Array Spectrometer as a Selective Detector for Comprehensive Two-Dimensional Gas Chromatography: Concept and First Results
    Groeger, Thomas
    Gruber, Beate
    Harrison, Dale
    Saraji-Bozorgzad, Mohammad
    Mthembu, Makhosazana
    Sutherland, Aimee
    Zimmermann, Ralf
    ANALYTICAL CHEMISTRY, 2016, 88 (06) : 3031 - 3039
  • [9] Essential Oils of New Lippia alba Genotypes Analyzed by Flow-Modulated Comprehensive Two-Dimensional Gas Chromatography (GCxGC) and Chemometric Analysis
    Gimenes, Leila
    Silva, Julio Cesar R. Lopes
    Facanali, Roselaine
    Hantao, Leandro Wang
    Siqueira, Walter Jose
    Marques, Marcia Ortiz Mayo
    MOLECULES, 2021, 26 (08):
  • [10] plug im ! software for comprehensive two-dimensional gas chromatography with vacuum ultraviolet detection - A tutorial
    Lelevic, Aleksandra
    Souchon, Vincent
    Geantet, Christophe
    Lorentz, Chantal
    Moreaud, Maxime
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2022, 231