Intraoperative 3D imaging of the facial skeleton using the SIREMOBIL Iso-C3D

被引:60
作者
Heiland, M
Schmelzle, R
Hebecker, A
Schulze, D
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Oral & Maxillofacial Surg, D-20246 Hamburg, Germany
[2] Siemens AG, Med Solut, D-8520 Erlangen, Germany
[3] Univ Hamburg, Hosp Eppendorf, Dept Oral Radiol, D-20246 Hamburg, Germany
关键词
fluoroscopy; cone beam computed tomography; intraoperative 3D imaging; facial skeleton;
D O I
10.1259/dmfr/15309653
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: With respect to high-contrast structures, cone beam computed tomography (CBCT) offers an alternative imaging modality to computed tomography (CT), requiring less radiation exposure. The C-arm system SIREMOBIL Iso-C-3D for three-dimensional (3D) reconstruction has made this modality available for intraoperative use. This paper presents the first intraoperative images of the facial skeleton using the SIREMOBIL Iso-C-3D. Methods: Cases of a zygomaticomaxillary complex fracture, a mandibular angle fracture and a bimaxillary repositioning osteotomy are described to demonstrate the application possibilities of this system in maxillofacial surgery. Results: In addition to the uncomplicated handling of the SIREMOBIL Iso-C-3D, generally important was the low level of metal artefacts in its primary and secondary reconstructions, even in close proximity to the material. However, it has to be kept in mind that while soft tissues are visualized using CBCT, information about soft tissue quality cannot be obtained. Conclusion: The SIREMOBIL Iso-C-3D generates intraoperative data sets suitable for the visualization of the facial bones after open reduction of fractures.
引用
收藏
页码:130 / 132
页数:3
相关论文
共 15 条
[1]   Analysis of treatment for isolated zygomaticomaxillary complex fractures [J].
Ellis, E ;
Kittidumkerng, W .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (04) :386-400
[2]   3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil ISO-C3D) [J].
Heiland, M ;
Schulze, D ;
Adam, G ;
Schmelzle, R .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (01) :21-25
[3]  
HEILAND M, 2003, EXCERPTA MED INT C S, V1256, P1230
[4]   Intraoperative computed tomography with the mobile CT Tomoscan M during surgical treatment of orbital fractures [J].
Hoelzle, F ;
Klein, M ;
Schwerdtner, O ;
Lueth, T ;
Albrecht, J ;
Hosten, N ;
Felix, R ;
Bier, J .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 30 (01) :26-31
[5]  
Hoffmann J, 2002, Mund Kiefer Gesichtschir, V6, P346
[6]   Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT [J].
Kotsianos, D ;
Rock, C ;
Wirth, S ;
Linsenmaier, U ;
Brandl, R ;
Fischer, T ;
Euler, E ;
Mutschler, W ;
Pfeifer, KJ ;
Reiser, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (01) :82-87
[7]   Complications of mandibular fractures in an urban teaching center [J].
Lamphier, J ;
Ziccardi, V ;
Ruvo, A ;
Janel, M .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (07) :745-749
[8]   Three-dimensional CT with a modified C-arm image intensifier: Feasibility [J].
Linsenmaier, U ;
Rock, C ;
Euler, E ;
Wirth, S ;
Brandl, R ;
Kotsianos, D ;
Mutschler, W ;
Pfeifer, KJ .
RADIOLOGY, 2002, 224 (01) :286-292
[9]  
Manson P N, 1999, Arch Facial Plast Surg, V1, P25, DOI 10.1001/archfaci.1.1.25
[10]  
MANSON PN, 1990, PLAST RECONSTR SURG, V85, P202, DOI 10.1097/00006534-199002000-00006