Impact of different values of prosthesis-patient mismatch on outcome in male patients with aortic valve replacement

被引:8
|
作者
Mannacio, Vito A. [1 ]
Mannacio, Luigi [1 ]
Antignano, Anita [2 ]
Pinna, Giovanni B. [1 ]
Giordano, Raffaele [1 ]
Mottola, Michele [1 ]
Iannelli, Gabriele [1 ]
机构
[1] Univ Federico II, Sch Med, Dept Cardiac Surg, Via S Domenico 62, I-80127 Naples, Italy
[2] Azienda Osped Santobono Pausillipon, Dept Cardiol, Naples, Italy
关键词
aortic valve replacement; prosthesis-patient mismatch; risk stratification; surgery; ventricular hypertrophy; LONG-TERM SURVIVAL; VENTRICULAR MASS REGRESSION; DIASTOLIC FUNCTION; ECHOCARDIOGRAPHY; STENOSIS; RECOMMENDATIONS; MORTALITY; SIZE;
D O I
10.2459/JCM.0000000000000508
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Mortality and left ventricular mass (LVM) recovery/regression after aortic valve replacement in patients with prosthesis-patient mismatch (PPM) is controversial. This study evaluated the impact of different values of indexed effective orifice area (EOAi) in male patients on mortality and indexed LVM (ILVM) recovery/regression. Method The study recruited 376 male patients with and without PPM after aortic valve replacement with different EOAi cut-off values. Results At EOAi 0.85 cm(2)/m(2) or less, 295 patients had PPM (78.5%). ILVM recovery occurred in 60.5% of no-PPM patients versus 46.1% of patients with PPM ( P = .003), and ILVM regression was 35 versus 25% (P<0.001). Time for ILVM regression was shorter in no-PPM group. At EOAi 0.75 cm(2)/m(2) or less, 201 patients had PPM (53.4%). ILVM recovery occurred in 55.4% of no-PPM patients versus 45.2% of patients with PPM (P = 0.06), regression was 32 versus 29% (P = 0.09). Time for ILVM regression was similar between groups. Regardless the cut-off value for PPM definition, mortality was similar. Conclusion LVM recovery/regression, but not mortality, was different at different EOAi. The cut-off value at EOAi 0.75 cm(2)/m(2) or less guaranteed a more balanced patient distribution between groups and the best compromise between specificity and sensitivity.
引用
收藏
页码:366 / 373
页数:8
相关论文
共 50 条
  • [1] Impact of prosthesis-patient mismatch on early and late mortality after aortic valve replacement
    Koene, Bart M.
    Hamad, Mohamed A. Soliman
    Bouma, Wobbe
    Mariani, Massimo A.
    Peels, Kathinka C.
    van Dantzig, Jan-Melle
    van Straten, Albert H.
    JOURNAL OF CARDIOTHORACIC SURGERY, 2013, 8
  • [2] Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement
    Dayan, Victor
    Vignolo, Gustavo
    Soca, Gerardo
    Paganini, Juan Jose
    Brusich, Daniel
    Pibarot, Philippe
    JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) : 924 - 933
  • [3] Prosthesis-Patient Mismatch in the Transcatheter Aortic Valve Replacement Era
    Tuzcu, E. Murat
    Oezkan, Alper
    Kapadia, Samir R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1919 - 1922
  • [4] Prosthesis-Patient Mismatch After "High-Risk" Aortic Valve Replacement
    Popma, Jeffrey J.
    Khabbaz, Kamal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (13) : 1335 - 1338
  • [5] Impact of prosthesis-patient mismatch on early haemodynamic status after aortic valve replacement
    Kindo, Michel
    Minh, Tam Hoang
    Perrier, Stephanie
    Petit-Eisenmann, Helene
    Bentz, Jonathan
    Cristinar, Mircea
    Ajob, Gharib
    Collange, Olivier
    Mazzucotelli, Jean-Philippe
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (01) : 48 - 54
  • [6] Impact of Flow on Prosthesis-Patient Mismatch Following Transcatheter and Surgical Aortic Valve Replacement
    Abbas, Amr E.
    Ternacle, Julien
    Pibarot, Philippe
    Xu, Ke
    Alu, Maria
    Rogers, Erin
    Hahn, Rebecca T.
    Leon, Martin
    Thourani, Vinod H.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2021, 14 (08) : E012364
  • [7] Hemodynamic and Clinical Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation
    Ewe, See Hooi
    Muratori, Manuela
    Delgado, Victoria
    Pepi, Mauro
    Tamborini, Gloria
    Fusini, Laura
    Klautz, Robert J. M.
    Gripari, Paola
    Bax, Jeroen J.
    Fusari, Melissa
    Schalij, Martin J.
    Marsan, Nina Ajmone
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1910 - 1918
  • [8] Overcoming prosthesis-patient mismatch with transcatheter aortic valve replacement
    Grubb, Kendra J.
    Tom, Stephanie K.
    Sultan, Ibrahim
    Sa, Michel Pompeu
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 236 - 243
  • [9] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [10] Prosthesis-patient mismatch after aortic valve replacement
    Dahou A.
    Mahjoub H.
    Pibarot P.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (11)