Experimental study on the performance of a multi-functional domestic air conditioner with integrated water heater

被引:13
作者
Dong, Jiankai [1 ]
Li, Hui [1 ]
Yao, Yang [1 ]
Jiang, Yiqiang [1 ]
Zhang, Xinran [2 ]
机构
[1] Harbin Inst Technol, Sch Municipal & Environm Engn, Harbin, Peoples R China
[2] China Aviat Planning & Design Inst Grp Co Ltd, Beijing, Peoples R China
基金
中国博士后科学基金;
关键词
Heat pump; Air conditioner; Domestic hot water supply; By-pass pipe; Energy-saving; RESIDENTIAL BUILDINGS; HONG-KONG; RECOVERY; SEHRAC; PUMP;
D O I
10.1016/j.applthermaleng.2017.01.086
中图分类号
O414.1 [热力学];
学科分类号
摘要
The recovery of condenser heat is concerned one of the most effective methods to curb energy consumption in residential dwellings. Aiming at recovering the condenser heat of domestic air conditioner, this paper experimentally studied a multi-functional domestic air conditioner with integrated water heater (MDACWH) which can effectively provide space - cooling and domestic hot water simultaneously. The dynamic operation characteristics, such as hot water supply and energy efficiency were tested to verify the availability of the MDACWH. The results showed that the MDACWH can effectively heat the domestic hot water without losing its cooling capacity. It was also found that with the use of MDACWH, the coefficient of comprehensive energy performance of the MDACWH was about 1.58 times higher than that of the unmodified experimental unit. Furthermore, the water-heating time was shorten remarkably from 128.5 min to 22.0 min. The novel domestic air conditioner, compared with the unmodified initial prototype, can be more practical and provide significant energy savings in space-cooling and hot water supply. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:393 / 401
页数:9
相关论文
共 50 条
[41]   Working performance of R-32 two-stage compression system in domestic air-conditioner [J].
Xu Shuxue ;
Ma Guoyuan .
ENERGY AND BUILDINGS, 2015, 93 :324-331
[42]   A novel multi-functional water facade system for energy saving and blast resisting [J].
Wang, Yonghui ;
Liew, J. Y. Richard ;
Lee, Siew Chin .
MATERIALS & DESIGN, 2016, 106 :98-111
[43]   Experimental Thermal Performance of a Novel Solar-Air Source Heat Pump System for Domestic Water Heating [J].
Xu, Guoying ;
Zhang, Xiaosong ;
Deng, Shiming ;
Zhang, Yuehong .
6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, :1984-1991
[44]   The Experimental Study of TiO2 nano compound coating applied in Air Conditioner [J].
Wang, Anling ;
Xiong, Ligui ;
Chen, Weidong ;
Liu, Xiangyun .
ADVANCED MATERIALS, PTS 1-3, 2012, 415-417 :353-+
[45]   Experimental study on the performance consistency diagnosis of split-type air conditioner based double colour ball matching rule [J].
Hu, Lulu ;
Chen, Hui ;
Miao, Yike ;
Chen, Cunfei ;
Liu, Yingwen .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2025, 177 :305-319
[46]   Performance assessment of an air source heat pump water heater from exergy aspect [J].
Ozturk, M. Mete ;
Dogan, Bahadir ;
Erbay, L. Berrin .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 42
[47]   Analysis and experimental study on ground source heat pump water heater [J].
Li Shu-hong ;
Shan Kui ;
Zhang Xiao-song .
JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 :258-262
[48]   Experimental and theoretical study on an air-source heat pump water heater for northern China in cold winter: Effects of environment temperature and switch of operating modes [J].
Xu, Yingjie ;
Huang, Yuangong ;
Jiang, Ning ;
Song, Mengjie ;
Xie, Xiaodong ;
Xu, Xiaoxiao .
ENERGY AND BUILDINGS, 2019, 191 :164-173
[49]   The numerical study of the thermal performance of a condensing gas-water heater [J].
Cao, Weixue ;
Liu, Fengguo ;
You, Xue-Yi .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2018, 74 (08) :1468-1485
[50]   Performance of a multi-functional direct-expansion solar assisted heat pump system [J].
Kuang, Y. H. ;
Wang, R. Z. .
SOLAR ENERGY, 2006, 80 (07) :795-803