Investigation of hydrodynamic and mass transfer of mercaptan extraction in pulsed and non-pulsed packed columns

被引:14
作者
Amani, Pouria [1 ]
Amani, Mohammad [2 ]
Hasanvandian, Reza [1 ]
机构
[1] Univ Tehran, Sch Engn, Dept Chem Engn, Tehran, Iran
[2] Shahid Beheshti Univ, Mech & Energy Engn Dept, Tehran, Iran
关键词
Liquid-liquid Extraction; Mercaptan Removal; Pulsed Packed Column; Sulfrex Process; Axial Dispersion Model; LIQUID-LIQUID-EXTRACTION; DISPERSED-PHASE HOLDUP; DROP SIZE DISTRIBUTION; CHARACTERISTIC VELOCITY; STRUCTURED PACKING; AXIAL-DISPERSION; BED COLUMN; REMOVAL; SIMULATION; MODEL;
D O I
10.1007/s11814-017-0042-0
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We investigated the hydrodynamic behavior and mass transfer characteristics of a pilot-scale conventional packed bed extraction column of mercaptan removal from liquid propane. The extraction column was filled with pall rings structured packing where mercaptan was extracted from the continuous phase to the dispersed phase, accompanied by a chemical reaction in propane-mercaptan-caustic system. The pulsing was introduced into the column to enhance the mass transfer rate. Hydrodynamic parameters such as hold up, flooding velocity and mean drop size were studied together with the effect of chemical reaction on increasing mass transfer performance. Finally, the mass transfer and axial mixing coefficients were obtained from the optimization of data by ADM. It was found that at the pulsation intensity from 0.003 to 0.007 m/s, the maximum mass transfer and minimum axial mixing occurred and it can be concluded that pulsation improves the efficiency of mass transfer just at low intensities.
引用
收藏
页码:1456 / 1465
页数:10
相关论文
共 56 条
[31]   Mass transfer performance in a coalescence-dispersion pulsed sieve plate extraction column [J].
Li, HB ;
Luo, GS ;
Fei, WY ;
Wang, JD .
CHEMICAL ENGINEERING JOURNAL, 2000, 78 (2-3) :225-229
[32]   Improved solid-phase extraction procedure for the isolation and in-sorbent pentafluorobenzyl alkylation of polyfunctional mercaptans Optimized procedure and analytical applications [J].
Mateo-Vivaracho, Laura ;
Cacho, Juan ;
Ferreira, Vicente .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1185 (01) :9-18
[33]  
McCabe WL, 1993, UNIT OPERATIONS CHEM
[34]  
Mehmandoost S., 2005, PROPANE TREATMENT UN
[35]   Experimental Investigation and CFD Modeling of Hydrodynamic Parameters in a Pulsed Packed Column [J].
Mirzaie, Maryam ;
Sarrafi, Amir ;
Pour, Hasan Hashemi ;
Baghaie, Ali ;
Molaeinasab, Mehdi .
SOLVENT EXTRACTION AND ION EXCHANGE, 2016, 34 (07) :643-660
[36]  
Mohanty S, 2000, REV CHEM ENG, V16, P199
[37]   Adsorptive separation of rhenium and rhodium in nitric acid solution using a column packed with an extractant impregnated resin [J].
Moon, Jei-Kwon ;
Jung, Chong-Hun ;
Lee, Eil-Hee ;
Lee, Byung-Chul .
KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2006, 23 (06) :1023-1027
[38]   Modeling and simulation of a liquid extraction column with structured packing [J].
Morales, C. ;
Elman, H. ;
Perez, A. .
COMPUTERS & CHEMICAL ENGINEERING, 2007, 31 (12) :1694-1701
[39]   DISPERSED PHASE HOLDUP AND DROP SIZE DISTRIBUTION IN PULSED PLATE COLUMNS [J].
PRABHAKAR, A ;
SRINIKETAN, G ;
VARMA, YBG .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1988, 66 (02) :232-240
[40]   CFD modeling of the effect of absorbent size on absorption performance of a packed bed column [J].
Rahimi, Masoud ;
Mohseni, Mohsen .