Effect of the Enhancement Threshold on the Computer-Aided Detection of Breast Cancer using MRI

被引:18
作者
Levman, Jacob E. D. [1 ]
Causer, Petrina [1 ]
Warner, Ellen [1 ]
Martel, Anne L. [1 ]
机构
[1] Univ Toronto, Sunnybrook Res Inst, Dept Med Biophys, Toronto, ON M4N 3M5, Canada
关键词
Breast imaging; computer-aided detection; enhancement threshold; magnetic resonance imaging; CONTRALATERAL BREAST; NEOADJUVANT CHEMOTHERAPY; DISCRIMINATING BENIGN; MALIGNANT LESIONS; CLASSIFICATION; IMAGES; MAMMOGRAPHY; SYSTEM; CAD;
D O I
10.1016/j.acra.2009.03.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To evaluate the effect that variations in the enhancement threshold have on the diagnostic accuracy of two computer-aided detection (CAD) systems for magnetic resonance based breast cancer screening. Materials and Methods. Informed consent was obtained from all patients participating in cancer screening and this study was approved by the participating institution's review board. This retrospective study was nested in a prospective, single-institution, high-risk, breast screening study involving dynamic contrast-enhanced magnetic resonance imaging. Only those screening examinations (n = 223) for which a histopathological diagnosis was available were included. Two CAD methods were performed: the signal enhancement ratio (SER) and support vector machines (SVMs). Statistical analysis was performed by tracking changes in each CAD test's diagnostic accuracy (eg, receiver-operating characteristic [ROC] curve area, maximum possible sensitivity) with changes in the enhancement threshold. Results. The enhancement threshold plays a significant role in affecting a CAD test's potential sensitivity, ROC curve area, and number of assumed true and false-positive predictions per cancerous examination. A high threshold can also limit the CAD-based detection of the full size of a lesion. Conclusions. Enhancement thresholds can limit a CAD test's ability to diagnose a lesion's full size and as such should not be raised above 60%. The clinically used SER method exhibits a high rate of false positives at low enhancement thresholds and as such the threshold should not be set lower than 50%. The SVM method yielded better results in our study than the SER method at clinically realistic enhancement thresholds.
引用
收藏
页码:1064 / 1069
页数:6
相关论文
共 27 条
[21]   Contrast-enhanced MR mammography for evaluation of the contralateral breast in patients with diagnosed unilateral breast cancer or high-risk lesions [J].
Pediconi, Federica ;
Catalano, Carlo ;
Roselli, Antonella ;
Padula, Simona ;
Altomari, Fiorella ;
Moriconi, Enrica ;
Pronio, Anna Maria ;
Kirchin, Miles A. ;
Passariello, Roberto .
RADIOLOGY, 2007, 243 (03) :670-680
[22]   Morphologic blooming in breast MRI as a characterization of margin for discriminating benign from malignant lesions [J].
Penn, Alan ;
Thompson, Scott ;
Brem, Rachel ;
Lehman, Constance ;
Weatherall, Paul ;
Schnall, Mitchell ;
Newstead, Gillian ;
Conant, Emily ;
Ascher, Susan ;
Morris, Elizabeth ;
Pisano, Etta .
ACADEMIC RADIOLOGY, 2006, 13 (11) :1344-1354
[23]   Neural network approach to the segmentation and classification of dynamic magnetic resonance images of the breast:: Comparison with empiric and quantitative kinetic parameters [J].
Szabó, BK ;
Aspelin, P ;
Wiberg, MK .
ACADEMIC RADIOLOGY, 2004, 11 (12) :1344-1354
[24]   Breast cancer detection in gadolinium-enhanced MR images by static region descriptors and neural networks [J].
Tzacheva, AA ;
Najarian, K ;
Brockway, JP .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :337-342
[25]   Surveillance of BRCA1 and BRCA2 mutation carriers with magnetic resonance imaging, ultrasound, mammography, and clinical breast examination [J].
Warner, E ;
Plewes, DB ;
Hill, KA ;
Causer, PA ;
Zubovits, JT ;
Jong, RA ;
Cutrara, MR ;
DeBoer, G ;
Yaffe, MJ ;
Messner, SJ ;
Meschino, WS ;
Piron, CA ;
Narod, SA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 292 (11) :1317-1325
[26]   A test of performance of breast MRI interpretation in a multicentre screening study [J].
Warren, Ruth ;
Hayes, Carmel ;
Pointon, Linda ;
Hoff, Rebecca ;
Gilbert, Fiona J. ;
Padhani, Anwar R. ;
Rubin, Caroline ;
Kaplan, Glenda ;
Raza, Kauza ;
Wilkinson, Laura ;
Hall-Craggs, Margaret ;
Kessar, Preminda ;
Rankin, Sheila ;
Dixon, Adrian K. ;
Walsh, James ;
Turnbull, Lindsay ;
Britton, Peter ;
Sinnatamby, Ruchi ;
Easton, Doug ;
Thompson, Deborah ;
Lakhani, Sunil R. ;
Leach, Martin O. .
MAGNETIC RESONANCE IMAGING, 2006, 24 (07) :917-929
[27]   Breast MR imaging: Computer-aided evaluation program for discriminating benign from malignant lesions [J].
Williams, Teresa C. ;
DeMartini, Wendy B. ;
Partridge, Savannah C. ;
Peacock, Sue ;
Lehman, Constance D. .
RADIOLOGY, 2007, 244 (01) :94-103