Underestimation of rat serum vancomycin concentrations measured by an enzyme-multiplied immunoassay technique and the strategy for its avoidance

被引:9
|
作者
Konishi, Hiroki [1 ]
Iga, Ikumi [1 ,2 ]
Nagai, Katsuhito [1 ]
机构
[1] Osaka Ohtani Univ, Lab Clin Pharm & Therapeut, Fac Pharm, Tondabayashi 5848540, Japan
[2] Shiga Hosp, Natl Hosp Org, Div Pharm, Higashiomi, Japan
关键词
Viva-E analyzer; underestimation; enzyme-multiplied immunoassay technique; rat serum; vancomycin concentration; LIQUID-CHROMATOGRAPHY; TISSUE CONCENTRATIONS; MASS-SPECTROMETRY; PLASMA SAMPLES; PHARMACOKINETICS; ACID; BIOAVAILABILITY; NEPHROTOXICITY; LEVOFLOXACIN; CYCLOSPORINE;
D O I
10.1002/dta.1511
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An enzyme-multiplied immunoassay technique (EMIT) has been widely adopted for the measurement of serum concentrations of vancomycin (VCM) in clinical practice. Because of the growing demand for its application to fundamental pharmacokinetic studies, we examined whether VCM concentrations in rat serum were accurately measured by EMIT. It was found that measured values of known amounts of VCM spiked to rat serum were markedly underestimated with a large analytical variance. When ultrafiltrated rat serum was used as the sample matrix, interference was significantly improved, and the degree of underestimation was attenuated also by diluting samples with physiological saline. These results suggest that endogenous substances of a high molecular weight in rat serum interfere with the analysis of VCM concentrations by EMIT. However, measured values of rat serum VCM concentrations by EMIT were restored to theoretical levels by exposing samples to 70 degrees C for 3-7 min. A likely explanation for the avoidance of interference is that an appropriate thermal force eliminated the immunological function of endogenous substances falsely recognizing VCM without affecting the VCM molecule itself. Regarding serum samples collected from rats that were administered VCM, values measured by EMIT following the heat-treatment agreed well with those by the high performance liquid chromatography (HPLC) method. This is the first report showing interference by endogenous high-molecular substances in the measurement of drug concentrations in rat serum using EMIT. Our findings will contribute to the appropriate use of VCM based on evidence provided by clinical-oriented rat experiments requiring the measurement of serum VCM concentrations by EMIT. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:350 / 356
页数:7
相关论文
共 46 条
  • [31] Resistin concentrations in murine adipose tissue and serum measured by a new enzyme immunoassay
    Fujinami, Aya
    Ohta, Kiyoe
    Matsui, Hidehito
    Kitada, Naoko
    Kitaura, Yuko
    Kawahara, Yuji
    Obayashi, Hiroshi
    Kuno, Sadako
    Nakamura, Naoto
    Ohta, Mitsuhiro
    OBESITY, 2006, 14 (02) : 199 - 205
  • [32] ACCURACY OF SERUM ANTICONVULSANT MEASUREMENTS - COMPARISON OF ENZYME MULTIPLIED IMMUNOASSAY TECHNIQUE AND GAS-LIQUID-CHROMATOGRAPHY
    BERCHOU, RC
    LODI, RA
    SHERMAN, JA
    ANNALS OF CLINICAL BIOCHEMISTRY, 1979, 16 (JUL) : 205 - 208
  • [33] SERUM CREATININE CONCENTRATION AND THE DISCREPANCY BETWEEN ENZYME MULTIPLIED IMMUNOASSAY TECHNIQUE AND GAS-LIQUID-CHROMATOGRAPHIC PHENYTOIN LEVELS
    APPLE, FS
    WALKER, FC
    DIETZLER, DN
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1983, 13 (05): : 385 - 392
  • [34] VALIDATION OF THE ANALYSIS OF CARBAMAZEPINE AND ITS 10,11-EPOXIDE METABOLITE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FROM PLASMA - COMPARISON WITH GAS-CHROMATOGRAPHY AND THE ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE
    MARTENS, J
    BANDITT, P
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 620 (01): : 169 - 173
  • [35] Growth hormone induced alterations of leptin serum concentrations in dairy cows as measured by a novel enzyme immunoassay
    Sauerwein, H
    Heintges, U
    Hennies, A
    Selhorst, T
    Daxenberger, A
    LIVESTOCK PRODUCTION SCIENCE, 2004, 87 (2-3): : 189 - 195
  • [36] SERUM QUINIDINE CONCENTRATIONS AS MEASURED BY DIRECT FLUOROMETRY, DOUBLE-EXTRACTION FLUOROMETRY, AND ENZYME-IMMUNOASSAY
    BATRA, KK
    OMAND, J
    BASELT, RC
    CLINICAL CHEMISTRY, 1981, 27 (05) : 780 - 781
  • [37] Comparison of a Point-of-Care Testing with Enzyme-Multiplied Immunoassay Technique and Liquid Chromatography Combined With Tandem Mass Spectrometry Methods for Therapeutic Drug Monitoring of Mycophenolic Acid: A Preliminary Study
    Zhou, Hong
    Xiang, Hongping
    Cai, Jie
    Wang, Yirong
    Zhang, Min
    Han, Yong
    Zhang, Yu
    THERAPEUTIC DRUG MONITORING, 2021, 43 (05) : 630 - 636
  • [38] STUDY OF ENZYME MULTIPLIED IMMUNOASSAY TECHNIQUE (EMIT) FOR DETERMINATION OF SERUM DIGOXIN BY MEANS OF LKB-8600 REACTION-RATE ANALYZER
    KJOLLER, HM
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1977, 37 : 96 - 96
  • [39] COMPARISON OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AN ENZYME MULTIPLIED IMMUNOASSAY TECHNIQUE FOR THE ANALYSIS OF SERUM PROCAINAMIDE AND N-ACETYLPROCAINAMIDE
    GALLAHER, C
    HENDERSON, GL
    LOW, RI
    AMSTERDAM, EA
    MASON, DT
    JOURNAL OF CHROMATOGRAPHY, 1980, 181 (3-4): : 490 - 496
  • [40] A comparison of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and enzyme-multiplied immunoassay technique (EMIT) for the determination of the cyclosporin A concentration in whole blood from Chinese patients
    Li, Wenlong
    Li, Rong
    Liu, Huanjun
    Guo, Xi
    Shaikh, Abdul Sami
    Li, Pingli
    Wang, Benjie
    Guo, Ruichen
    Zhang, Rui
    BIOSCIENCE TRENDS, 2017, 11 (04) : 475 - 482