Micro-extraction by packed sorbent coupled on-line to a column-switching chromatography system - A case study on the determination of three beta-blockers in human urine

被引:9
作者
Satinsky, Dalibor [1 ]
Sobek, Vojtech [1 ]
Lhotska, Ivona [1 ]
Solich, Petr [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Ak Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
关键词
Microextraction; Liquid chromatography; Column switching; On-line extraction; Beta-blockers; Urine; TANDEM MASS-SPECTROMETRY; SAMPLES UTILIZING MICROEXTRACTION; SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLYCYCLIC AROMATIC-HYDROCARBONS; WASTE-WATER; SYRINGE ONLINE; PLASMA; MEPS; PHARMACEUTICALS;
D O I
10.1016/j.microc.2019.02.069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new approach for the automation of Micro-Extraction by Packed Sorbent (MEPS) as a solid phase extraction technique coupled directly to a column-switching chromatography system was presented. A new on-line hyphenation of the modern micro-extraction procedure with liquid chromatography was developed and used for human urine sample clean-up and pre-concentration of three beta-blockers - metoprolol, labetalol and propranolol before separation and determination. A commercial MEPS C-18 cartridge was coupled using Teflon holders into an HPLC system through a high-pressure six-port switching valve. Chromatographic separation was performed on a Triart YMC C-18 (50 mm x 4.6 mm) analytical column with 5 mu m multi-layered particles. The multilayered particle column showed extremely low flow-resistance (< 4.1 MPa) at a flow rate of 1.0 mL min(-1), and thus direct connection with a MEPS cartridge was possible. A mixture of acetonitrile and an aqueous solution of 0.5% triethylamine with acetic acid, with pH adjusted to 4.5 in the linear gradient elution mode was used. This mobile phase eluted beta-blockers from the MEPS mini-column directly onto the analytical column where the separation was carried out. Metoprolol, labetalol and propranolol were detected by a fluorescence detector at the lambda(ex) = 220 nm and lambda(em) = 315 nm wavelengths. The developed on-line MEPS-HPLC coupling showed satisfactory validation results with recovery ranging from 94.0 to 104.7% and precision in the range of 0.6-9.5% for all beta-blockers.
引用
收藏
页码:60 / 66
页数:7
相关论文
共 34 条
[31]   Fast and sensitive analysis of beta blockers by ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry [J].
Tomkova, Jana ;
Ondra, Peter ;
Kocianova, Eva ;
Vaclavik, Jan .
BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (07)
[32]   Simultaneous determination of β-blockers in human plasma using liquid chromatography-tandem mass spectrometry [J].
Umezawa, Hironobu ;
Lee, Xiao-Pen ;
Arima, Yoshiko ;
Hasegawa, Chika ;
Izawa, Hikaru ;
Kumazawa, Takeshi ;
Sato, Keizo .
BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) :702-711
[33]   Fully automated determination of macrocyclic musk fragrances in wastewater by microextraction by packed sorbents and large volume injection gas chromatography-mass spectrometry [J].
Vallecillos, Laura ;
Pocurull, Eva ;
Borrull, Francesc .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1264 :87-94
[34]   Sorbent, device, matrix and application in microextraction by packed sorbent (MEPS): A review [J].
Yang, Liu ;
Said, Rana ;
Abdel-Rehim, Mohamed .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1043 :33-43