Micro-extraction by packed sorbent coupled on-line to a column-switching chromatography system - A case study on the determination of three beta-blockers in human urine

被引:9
作者
Satinsky, Dalibor [1 ]
Sobek, Vojtech [1 ]
Lhotska, Ivona [1 ]
Solich, Petr [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Ak Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
关键词
Microextraction; Liquid chromatography; Column switching; On-line extraction; Beta-blockers; Urine; TANDEM MASS-SPECTROMETRY; SAMPLES UTILIZING MICROEXTRACTION; SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLYCYCLIC AROMATIC-HYDROCARBONS; WASTE-WATER; SYRINGE ONLINE; PLASMA; MEPS; PHARMACEUTICALS;
D O I
10.1016/j.microc.2019.02.069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new approach for the automation of Micro-Extraction by Packed Sorbent (MEPS) as a solid phase extraction technique coupled directly to a column-switching chromatography system was presented. A new on-line hyphenation of the modern micro-extraction procedure with liquid chromatography was developed and used for human urine sample clean-up and pre-concentration of three beta-blockers - metoprolol, labetalol and propranolol before separation and determination. A commercial MEPS C-18 cartridge was coupled using Teflon holders into an HPLC system through a high-pressure six-port switching valve. Chromatographic separation was performed on a Triart YMC C-18 (50 mm x 4.6 mm) analytical column with 5 mu m multi-layered particles. The multilayered particle column showed extremely low flow-resistance (< 4.1 MPa) at a flow rate of 1.0 mL min(-1), and thus direct connection with a MEPS cartridge was possible. A mixture of acetonitrile and an aqueous solution of 0.5% triethylamine with acetic acid, with pH adjusted to 4.5 in the linear gradient elution mode was used. This mobile phase eluted beta-blockers from the MEPS mini-column directly onto the analytical column where the separation was carried out. Metoprolol, labetalol and propranolol were detected by a fluorescence detector at the lambda(ex) = 220 nm and lambda(em) = 315 nm wavelengths. The developed on-line MEPS-HPLC coupling showed satisfactory validation results with recovery ranging from 94.0 to 104.7% and precision in the range of 0.6-9.5% for all beta-blockers.
引用
收藏
页码:60 / 66
页数:7
相关论文
共 34 条
[1]   New trend in sample preparation: on-line microextraction in packed syringe for liquid and gas chromatography applications - I. Determination of local anaesthetics in human plasma samples using gas chromatography-mass spectrometry [J].
Abdel-Rehim, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 801 (02) :317-321
[2]   Quantification of 4-OH-2,6-xylidine and its conjugates in human urine samples utilising microextraction in packed syringe on-line with liquid chromatography and electrospray tandem mass spectrometry (MEPS-LC-MS/MS) [J].
Abdel-Rehim, Mohamed ;
Askemark, Yvonne ;
Norsten-Hoog, Carina ;
Pettersson, Karl-Johan ;
Halldin, Magnus .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (16) :2413-2424
[3]   Quantification of ropivacaine and its major metabolites in human urine samples utilizing microextraction in a packed syringe automated with liquid chromatography-tandem mass spectrometry (MEPS-LC-MS/MS) [J].
Abdel-Rehim, Mohamed ;
Dahlgren, Marie ;
Blomberg, Lars .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (11) :1658-1661
[4]   Graphite-based microextraction by packed sorbent for online extraction of β-blockers from human plasma samples [J].
Abuzooda, Thana ;
Amini, Ahmad ;
Abdel-Rehim, Mohamed .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 992 :86-90
[5]   Nanomaterials as sorbents for sample preparation in bioanalysis: A review [J].
Ahmadi, Mazaher ;
Elmongy, Hatem ;
Madrakian, Tayyebeh ;
Abdel-Rehim, Mohamed .
ANALYTICA CHIMICA ACTA, 2017, 958 :1-21
[6]   Fate of β-blocker human pharmaceuticals in surface water: Comparison of measured and simulated concentrations in the Glatt Valley Watershed, Switzerland [J].
Alder, Alfredo C. ;
Schaffner, Christian ;
Majewsky, Marius ;
Klasmeier, Joerg ;
Fenner, Kathrin .
WATER RESEARCH, 2010, 44 (03) :936-948
[7]   Matrix effects and recovery calculations in analyses of pharmaceuticals based on the determination of β-blockers and β-agonists in environmental samples [J].
Caban, Magda ;
Migowska, Natalia ;
Stepnowski, Piotr ;
Kwiatkowski, Marek ;
Kumirska, Jolanta .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1258 :117-127
[8]   Determination of polycyclic and nitro musks in environmental water samples by means of microextraction by packed sorbents coupled to large volume injection-gas chromatography-mass spectrometry analysis [J].
Cavalheiro, J. ;
Prieto, A. ;
Monperrus, M. ;
Etxebarria, N. ;
Zuloaga, O. .
ANALYTICA CHIMICA ACTA, 2013, 773 :68-75
[9]   Fast and sensitive environmental analysis utilizing microextraction in packed syringe online with gas chromatography-mass spectrometry - Determination of polycyclic aromatic hydrocarbons in water [J].
El-Beqqali, Aziza ;
Kussak, Anders ;
Abdel-Rehim, Mohamed .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1114 (02) :234-238
[10]   Determination of polycyclic aromatic hydrocarbons in water samples using online microextraction by packed sorbent coupled with gas chromatography-mass spectrometry [J].
Fu, Shuai ;
Fan, Jun ;
Hashi, Yuki ;
Chen, Zilin .
TALANTA, 2012, 94 :152-157