Transmission of bone-conducted sound in the human skull measured by cochlear vibrations

被引:99
作者
Eeg-Olofsson, Mans [1 ]
Stenfelt, Stefan [1 ]
Tjellstrom, Anders [2 ]
Granstrom, Gosta [2 ]
机构
[1] Linkoping Univ, Dept Clin & Expt Med, Div Tech Audiol, Linkoping, Sweden
[2] Univ Gothenburg, Dept Otolaryngol Head & Neck Surg, Gothenburg, Sweden
关键词
Bone conduction; Distance from the cochlea; Squamosal suture; Laser Doppler vibrometer; Implantable bone conduction hearing aid;
D O I
10.1080/14992020802311216
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
One limitation with the Bone Anchored Hearing Aid (Baha) is too poor amplification for patients with moderate to severe sensorineural hearing losses. Therefore, we investigated if bone conducted (BC) sound transmission improves when the stimulation approaches the cochlea. Also the influence from the squamosal suture on BC sound transmission was investigated. Both sides of the heads on seven human cadavers were used and vibrational stimulation was applied at eight positions on each side with a frequency range of 0.1-10 kHz. A laser Doppler vibrometer was used to measure the resulting velocity of the cochlear promontory. It was found that the velocity of the promontory increases as the stimulation position approaches the cochlea; this was especially apparent at distances within 2.5 cm from the ear canal opening and when the stimulation position was in the opened mastoid. At frequencies above 500 Hz there was on average 10 to 20 dB greater vibrational response at the cochlea when the stimulation was close to the cochlea compared with the normal Baha position. Moreover, even if there were general indications of attenuation of BC sound when passing the squamosal suture, an effect from the suture could not be conclusively determined.
引用
收藏
页码:761 / 769
页数:9
相关论文
共 23 条
[1]  
Anson B. J., 1973, SURG ANATOMY TEMPORA
[2]   Validity and clinical significance of biomechanical testing of implant/bone interface [J].
Aparicio, Carlos ;
Lang, Niklaus R. ;
Rangert, Bo .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 :2-7
[3]  
Bekesy G, 1960, EXPT HEARING
[4]   ON THE TRANSMISSION OF SOUND GENERATED BY AN ELECTROMAGNETIC DEVICE FROM THE MASTOID PROCESS TO THE PETROUS BONE [J].
BUCHMAN, E ;
ROSENHOUSE, G ;
SHUPAK, A ;
SHIMONI, U .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 90 (02) :895-903
[5]   Bone conduction experiments in animals - evidence for a non-osseous mechanism [J].
Freeman, S ;
Sichel, JY ;
Sohmer, H .
HEARING RESEARCH, 2000, 146 (1-2) :72-80
[6]   THE MECHANICAL POINT IMPEDANCE OF THE HUMAN HEAD, WITH AND WITHOUT SKIN PENETRATION [J].
HAKANSSON, B ;
CARLSSON, P ;
TJELLSTROM, A .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1986, 80 (04) :1065-1075
[7]   SKULL SIMULATOR FOR DIRECT BONE CONDUCTION HEARING DEVICES [J].
HAKANSSON, B ;
CARLSSON, P .
SCANDINAVIAN AUDIOLOGY, 1989, 18 (02) :91-98
[8]   RESONANCE FREQUENCIES OF THE HUMAN SKULL IN-VIVO [J].
HAKANSSON, B ;
BRANDT, A ;
CARLSSON, P ;
TJELLSTROM, A .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 95 (03) :1474-1481
[9]  
HAKANSSON B, OTOL NEUROT IN PRESS
[10]  
Mao JJ, 2003, ANGLE ORTHOD, V73, P128