Noise Cancellation in Long-Range Surface Plasmon Dual-Output Mach-Zehnder Interferometers

被引:9
|
作者
Fan, Hui [1 ]
Berini, Pierre [1 ,2 ]
机构
[1] Univ Ottawa, Sch Elect Engn & Comp Sci, Ottawa, ON K1N 6N5, Canada
[2] Univ Ottawa, Dept Phys, Ottawa, ON K1N 6N5, Canada
关键词
Dual-output Mach-Zehnder interferometer; long-range surface plasmon-polariton; noise cancellation; thermo-optic modulation; FIBER INTERFEROMETERS; DIRECTIONAL-COUPLERS; POLARITON WAVES; FABRICATION; BIOSENSOR; DEVICES; GUIDES; SENSOR; CYTOP;
D O I
10.1109/JLT.2013.2271217
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The characterisation of dual-output Mach-Zehnder interferometers operating with long-range surface plasmon-polaritons at a free-space wavelength of similar to 1370 nm is reported. The devices were constructed by embedding Au stripes in Cytop claddings, and consist of a symmetric Mach-Zehnder interferometer in cascade with a 50:50 coupler. By injecting electric current via probes to generate heat in the active region in one arm of the interferometer, a phase difference between the arms was thermo-optically induced, modulating the optical power of the two outputs. The outputs were complementary as expected theoretically, thus demonstrating the switching abilities of the structure. The advantages for sensing applications of a dual-output interferometer over a single-output one are a 2X larger dynamic range and the ability to cancel common noise and source fluctuations. The larger dynamic range and noise cancellation produced a minimum detectable phase shift 4X lower than obtained by monitoring a single output. The smallest value of Delta phi(min) obtained was similar to 3 mrad. The structure is especially promising for (bio)chemical sensing applications.
引用
收藏
页码:2606 / 2612
页数:7
相关论文
共 50 条
  • [1] Long-range surface plasmon triple-output Mach-Zehnder interferometers
    Fan, Hui
    Charbonneau, Robert
    Berini, Pierre
    OPTICS EXPRESS, 2014, 22 (04): : 4006 - 4020
  • [2] Bulk Sensing Using a Long-Range Surface-Plasmon Dual-Output Mach-Zehnder Interferometer
    Fan, Hui
    Berini, Pierre
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2016, 34 (11) : 2631 - 2638
  • [3] Mach-Zehnder refractometric sensor using long-range surface plasmon waveguides
    Khan, Asad
    Krupin, Oleksiy
    Lisicka-Skrzek, Ewa
    Berini, Pierre
    APPLIED PHYSICS LETTERS, 2013, 103 (11)
  • [4] Bulk sensing using a long-range surface-plasmon triple-output Mach-Zehnder interferometer
    Fan, Hui
    Berini, Pierre
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2016, 33 (06) : 1068 - 1074
  • [5] Hybrid photon-plasmon Mach-Zehnder interferometers for highly sensitive hydrogen sensing
    Gu, Fuxing
    Wu, Guoqing
    Zeng, Heping
    NANOSCALE, 2015, 7 (03) : 924 - 929
  • [6] Biosensing using long-range surface plasmon waveguides
    Krupin, Oleksiy
    Khodami, Maryam
    Fan, Hui
    Wong, Wei Ru
    Adikan, Faisal Rafiq Mahamd
    Berinia, Pierre
    INTEGRATED OPTICS: PHYSICS AND SIMULATIONS III, 2017, 10242
  • [7] Selective biosensing using straight long-range surface plasmon waveguides
    Krupin, O.
    Wang, Chen
    Berini, P.
    PHOTONICS NORTH 2013, 2013, 8915
  • [8] Measurement of Long-Range Surface Plasmon-Polariton devices in Cytop
    Fan, Hui
    Lisicka-Skrzek, Ewa
    Berini, Pierre
    PHOTONICS NORTH 2011, 2011, 8007
  • [9] Multichannel Long-Range Surface Plasmon Waveguides for Parallel Biosensing
    Wong, Wei Ru
    Fan, Hui
    Adikan, Faisal Rafiq Mahamd
    Berini, Pierre
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2018, 36 (23) : 5536 - 5546
  • [10] Strategies for leukemic biomarker detection using long-range surface plasmon-polaritons
    Krupin, O.
    Wang, C.
    Berini, P.
    PHOTONICS NORTH 2014, 2014, 9288