Ultrasound Common Carotid Artery Segmentation Based on Active Shape Model

被引:20
|
作者
Yang, Xin [1 ]
Jin, Jiaoying [2 ]
Xu, Mengling [2 ]
Wu, Huihui [2 ]
He, Wanji [3 ]
Yuchi, Ming [2 ]
Ding, Mingyue [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Multispectral Informat Proc Technol, IPRAI, Wuhan 430074, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Dept Biomed Engn, Image Proc & Intelligence Control Key Lab, Educ Minist China,Coll Life Sci & Technol, Wuhan 430074, Hubei, Peoples R China
[3] Shanghai Jiao Tong Univ, Biomed Instrument Inst, Med X Res Inst, Shanghai 200030, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
VESSEL WALL VOLUME; 3-DIMENSIONAL ULTRASOUND; RHEUMATOID-ARTHRITIS; BIFURCATION ANATOMY; BOUNDARY DETECTION; PLAQUE; ATHEROSCLEROSIS; IMAGES; RISK; QUANTIFICATION;
D O I
10.1155/2013/345968
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Carotid atherosclerosis is a major reason of stroke, a leading cause of death and disability. In this paper, a segmentation method based on Active Shape Model (ASM) is developed and evaluated to outline common carotid artery (CCA) for carotid atherosclerosis computer-aided evaluation and diagnosis. The proposed method is used to segment both media-adventitia-boundary (MAB) and lumen-intima-boundary (LIB) on transverse views slices from three-dimensional ultrasound (3D US) images. The data set consists of sixty-eight, 17 x 2 x 2, 3D US volume data acquired from the left and right carotid arteries of seventeen patients (eight treated with 80 mg atorvastatin and nine with placebo), who had carotid stenosis of 60% or more, at baseline and after three months of treatment. Manually outlined boundaries by expert are adopted as the ground truth for evaluation. For the MAB and LIB segmentations, respectively, the algorithm yielded Dice Similarity Coefficient (DSC) of 94.4% +/- 3.2% and 92.8% +/- 3.3%, mean absolute distances (MAD) of 0.26 +/- 0.18 mm and 0.33 +/- 0.21 mm, and maximum absolute distances (MAXD) of 0.75 +/- 0.46 mm and 0.84 +/- 0.39 mm. It took 4.3 +/- 0.5 mins to segment single 3D US images, while it took 11.7 +/- 1.2 mins for manual segmentation. The method would promote the translation of carotid 3D US to clinical care for the monitoring of the atherosclerotic disease progression and regression.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound
    Cary, Theodore W.
    Reamer, Courtney B.
    Sultan, Laith R.
    Mohler, Emile R., III
    Sehgal, Chandra M.
    MEDICAL PHYSICS, 2014, 41 (02)
  • [32] Semiautomatic segmentation of atherosclerotic carotid artery wall volume using 3D ultrasound imaging
    Hossain, Md. Murad
    AlMuhanna, Khalid
    Zhao, Limin
    Lal, Brajesh K.
    Sikdar, Siddhartha
    MEDICAL PHYSICS, 2015, 42 (04) : 2029 - 2043
  • [33] Carotid Artery Segmentation in Ultrasound Images and Measurement of Intima-Media Thickness
    Naik, Vaishali
    Gamad, R. S.
    Bansod, P. P.
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [34] Enhanced Segmentation Procedure for Intima-Adventitial Layers of Common Carotid Artery
    Savithri, V.
    Purushothaman, S.
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2010, 1 (03) : 78 - 81
  • [35] Wave Intensity Analysis in Mice: an Ultrasound-Based Study in the Abdominal Aorta and Common Carotid Artery
    Di Lascio, N.
    Kusmic, C.
    Stea, F.
    Faita, F.
    MEDICAL IMAGING 2017: ULTRASONIC IMAGING AND TOMOGRAPHY, 2017, 10139
  • [36] Three-dimensional ultrasound of carotid atherosclerosis: Semiautomated segmentation using a level set-based method
    Ukwatta, E.
    Awad, J.
    Ward, A. D.
    Buchanan, D.
    Samarabandu, J.
    Parraga, G.
    Fenster, A.
    MEDICAL PHYSICS, 2011, 38 (05) : 2479 - 2493
  • [37] Deep learning-based carotid media-adventitia and lumen-intima boundary segmentation from three-dimensional ultrasound images
    Zhou, Ran
    Fenster, Aaron
    Xia, Yujiao
    Spence, J. David
    Ding, Mingyue
    MEDICAL PHYSICS, 2019, 46 (07) : 3180 - 3193
  • [38] Hypothesis Validation of Far-Wall Brightness in Carotid-Artery Ultrasound for Feature-Based IMT Measurement Using a Combination of Level-Set Segmentation and Registration
    Molinari, Filippo
    Krishnamurthi, Ganapathy
    Acharya, U. Rajendra
    Sree, S. Vinitha
    Zeng, Guang
    Saba, Luca
    Nicolaides, Andrew
    Suri, Jasjit S.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (04) : 1054 - 1063
  • [39] A NEW APPROACH FOR CLASSIFICATION OF ATHEROSCLEROSIS OF COMMON CAROTID ARTERY FROM ULTRASOUND IMAGES
    Smitha, B.
    Joseph, K. Paul
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (01)
  • [40] Impact of Ultrasound Scanning Plane on Common Carotid Artery Longitudinal Wall Motion
    Bryans, Carol G.
    Cohen, Jeremy N.
    Athaide, Chloe E.
    Pugh, Christopher J. A.
    Au, Jason S.