Performance assessment of isolation methods for geometrical cerebral aneurysm analysis

被引:12
作者
Cardenes, Ruben [1 ,2 ]
Larrabide, Ignacio [1 ,2 ]
San Roman, Luis [3 ]
Frangi, Alejandro F. [1 ,2 ,4 ]
机构
[1] Univ Pompeu Fabra, Ctr Computat Imaging & Simulat Technol Biomed CIS, Barcelona, Spain
[2] CIBER BBN, Barcelona, Spain
[3] Hosp Clin Barcelona, Neurointervent Sect, CDIC, Barcelona, Spain
[4] Univ Sheffield, INSIGNEO Inst Biomed Imaging & Modeling, Dept Mech Engn, Sheffield, S Yorkshire, England
关键词
Intracranial aneurysm; Aneurysm isolation; Neck detection; Aneurysm risk assessment; INTRACRANIAL ANEURYSMS; RUPTURE RISK; QUANTIFICATION; FRAMEWORK;
D O I
10.1007/s11517-012-1003-8
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Geometrical aneurysm quantification is considered an important topic for the study of aneurysm formation, growth, risk of rupture and also in treatment planning. Usually, quantification involves aneurysm isolation, consisting in the operation of detecting the boundary between the aneurysm dome and its feeding arteries. This operation is sometimes performed manually, but it is a tedious task, subject to user variability. To obtain reproducible measurements, automatic techniques have been proposed. In this paper, we compare different aneurysm isolation techniques, two automatic and one manual-based on a cutting plane. All of them are compared against the results obtained by manual delineations of 26 real cases. We show from the results that automatic methods have good performance, providing results similar to manual methods in average. We also show that automatic methods improve reproducibility compared to direct measurements performed on volume rendering views. Each automatic method presents strengths and weaknesses in particular cases such as small aneurysms, aneurysms with multiple parent vessels or terminal aneurysms, but their reproducibility makes them suitable for robust population studies. Finally, based on this study, we have proposed a criterion that allows to use a combination of the two methods studied and that outperforms each of them individually.
引用
收藏
页码:343 / 352
页数:10
相关论文
共 17 条
[1]  
[Anonymous], 2011, PARAVIEW V3 4 0
[2]   Automated segmentation of cerebral vasculature with aneurysms in 3DRA and TOF-MRA using geodesic active regions: An evaluation study [J].
Bogunovic, Hrvoje ;
Maria Pozo, Jose ;
Cruz Villa-Uriol, Maria ;
Majoie, Charles B. L. M. ;
van den Berg, Rene ;
van Andel, Hugo A. F. Gratama ;
Macho, Juan M. ;
Blasco, Jordi ;
San Roman, Luis ;
Frangi, Alejandro F. .
MEDICAL PHYSICS, 2011, 38 (01) :210-222
[3]  
Bruijns J, 2007, FULLY AUTOMATIC CORR, P293
[4]   Automatic Aneurysm Neck Detection Using Surface Voronoi Diagrams [J].
Cardenes, Ruben ;
Maria Pozo, Jose ;
Bogunovic, Hrvoje ;
Larrabide, Ignacio ;
Frangi, Alejandro F. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (10) :1863-1876
[5]   Morphology parameters for intracranial aneurysm rupture risk assessment [J].
Dhar, Sujan ;
Tremmel, Markus ;
Mocco, J. ;
Kim, Minsuok ;
Yamamoto, Junichi ;
Siddiqui, Adnan H. ;
Hopkins, L. Nelson ;
Meng, Hui ;
Derdeyn, Colin ;
Dacey, Ralph G., Jr. ;
Macdonald, R. Loch ;
Carter, Bob ;
Fernandez-Miranda, Juan C. ;
Dumont, Aaron S. ;
Kassell, Neal F. .
NEUROSURGERY, 2008, 63 (02) :185-197
[6]   Three-Dimensional Blood Vessel Quantification via Centerline Deformation [J].
Kang, Dong-Goo ;
Suh, Dae Chul ;
Ra, Jong Beom .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (03) :405-414
[7]   Three-dimensional morphological analysis of intracranial aneurysms: A fully automated method for aneurysm sac isolation and quantification [J].
Larrabide, Ignacio ;
Cruz Villa-Uriol, Maria ;
Cardenes, Ruben ;
Maria Pozo, Jose ;
Macho, Juan ;
San Roman, Luis ;
Blasco, Jordi ;
Vivas, Elio ;
Marzo, Alberto ;
Hose, D. Rod ;
Frangi, Alejandro F. .
MEDICAL PHYSICS, 2011, 38 (05) :2439-2449
[8]  
Larrabide I, 2009, LECT NOTES COMPUT SC, V5528, P417, DOI 10.1007/978-3-642-01932-6_45
[9]   Three-dimensional geometrical characterization of cerebral aneurysms [J].
Ma, BS ;
Harbaugh, RE ;
Raghavan, ML .
ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (02) :264-273
[10]   Morphological characterization of intracranial aneurysms using 3-d moment invariants [J].
Millan, R. D. ;
Dempere-Marco, L. ;
Pozo, J. M. ;
Cebral, J. R. ;
Frangi, A. F. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (09) :1270-1282