Synergistic effect of ultrasonic pre-treatment combined with UV irradiation for secondary effluent disinfection

被引:30
作者
Jin, Xin [1 ]
Li, Zifu [1 ]
Xie, Lanlan [1 ]
Zhao, Yuan [1 ]
Wang, Tingting [1 ]
机构
[1] Univ Sci & Technol Beijing, Sch Civil & Environm Engn, Beijing 100083, Peoples R China
关键词
Secondary effluent disinfection; Ultraviolet; Ultrasound; Particle size distribution; Synergistic effect; WASTE-WATER DISINFECTION; PARTICLES; REACTORS;
D O I
10.1016/j.ultsonch.2013.03.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The ultraviolet (UV) disinfection efficiency is often affected by suspended solids (SS). Given their high concentration or large particle size, SS can scatter UV light and provide shielding for bacteria. Thus, ultrasound is often employed as a pre-treatment process to improve UV disinfection. This work investigated the synergistic effect of ultrasound combined with UV for secondary effluent disinfection. Bench-scale experiments were conducted in using samples obtained from secondary sedimentation tanks. These tanks belonged to three wastewater treatment plants in Beijing that use different kinds of biological treatment methods. Several parameters may contribute to the changes in the efficiency of ultrasound and UV disinfection. Thus, the frequency and energy density of ultrasound, as well as the SS, were investigated. Results demonstrated that samples which have relatively higher SS concentrations or higher percentages of larger particles have less disinfection efficiency using UV disinfection alone. However, the presence of ultrasound could improve the disinfection efficiency because it has synergistic effect. Changes in the particle size distribution and SS concentration notably affected the efficiency of UV disinfection. The efficiency of Escherichia coli elimination can be decreased by 1.2 log units as the SS concentration increases from 16.9 mg/l to 25.4 mg/l at a UV energy density of 40 mJ/cm(2). UV disinfection alone reduced the E. coli population by 3.4 log units. However, the synergistic disinfection of ultrasound and UV could reach 5.4 log units during the reduction of E. coli at a 40 kHz frequency and an energy density of 2.64 kJ/l. The additional synergistic effect is 1.1 log units. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1384 / 1389
页数:6
相关论文
共 18 条
[1]   Improved wastewater disinfection by ultrasonic pre-treatment [J].
Blume, T ;
Neis, U .
ULTRASONICS SONOCHEMISTRY, 2004, 11 (05) :333-336
[2]   Modeling of secondary treated wastewater disinfection by UV irradiation: Effects of suspended solids content [J].
Brahmi, Mounaouer ;
Belhadi, Noureddine Hamed ;
Hamdi, Helmi ;
Hassen, Abdennaceur .
JOURNAL OF ENVIRONMENTAL SCIENCES, 2010, 22 (08) :1218-1224
[3]   Preliminary assessment of transport processes influencing the penetration of chlorine into wastewater particles and the subsequent inactivation of particle-associated organisms [J].
Dietrich, JP ;
Basagaoglu, H ;
Loge, FJ ;
Ginn, TR .
WATER RESEARCH, 2003, 37 (01) :139-149
[4]   Modeling the inactivation of particle-associated coliform bacteria [J].
Emerick, RW ;
Loge, FJ ;
Ginn, T ;
Darby, JL .
WATER ENVIRONMENT RESEARCH, 2000, 72 (04) :432-438
[5]   Effects of ultrasound on suspended particles in municipal wastewater [J].
Gibson, John H. ;
Hon, Henrique ;
Farnood, Ramin ;
Droppo, Ian G. ;
Seto, Peter .
WATER RESEARCH, 2009, 43 (08) :2251-2259
[6]   Cavitational reactors for process intensification of chemical processing applications: A critical review [J].
Gogate, Parag R. .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2008, 47 (04) :515-527
[7]  
Gogate PR, 2006, CURR SCI INDIA, V91, P35
[8]   Sonochemical reactors: Important design and scale up considerations with a special emphasis on heterogeneous systems [J].
Gogate, Parag R. ;
Sutkar, Vinayak S. ;
Pandit, Aniruddha B. .
CHEMICAL ENGINEERING JOURNAL, 2011, 166 (03) :1066-1082
[9]   Sonophotocatalytic reactors for wastewater treatment: A critical review [J].
Gogate, PR ;
Pandit, AB .
AICHE JOURNAL, 2004, 50 (05) :1051-1079
[10]   A sonophotochemical reactor for the removal of formic acid from wastewater [J].
Gogate, PR ;
Mujumdar, S ;
Pandit, AB .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2002, 41 (14) :3370-3378