Metallized Film Power Capacitors End-of-Life Study Through Monitored Destruction Tests

被引:11
作者
Guillermin, Christophe [1 ]
Dujeu, Olivier [1 ]
Lupin, Jean-Marc [1 ]
机构
[1] Schneider Elect, Power Factor Correct & Harmon Filtering, F-74370 Pringy, France
关键词
Destruction test; metallized film capacitor; polypropylene; protection system; THERMAL-DECOMPOSITION; POLYPROPYLENE; CORROSION; MECHANISM; AC;
D O I
10.1109/TPWRD.2012.2216551
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A wide range of experiments was performed on metallized film capacitors. The monitoring of destruction tests was used to analyze the electrical properties of artificial critical defects. It is shown herein that these defects in the windings of the capacitors have a wide range of electrical properties and the behavior of the capacitor in the test is strongly related to these properties. A model is proposed to describe the degeneration of dielectric failure, the use of this model can help to predict the behavior of capacitors when they reach the end of life and to a more accurate design of the protection systems.
引用
收藏
页码:368 / 375
页数:8
相关论文
共 33 条
[31]   Self-healing of metallized polymer films of different nature [J].
Walgenwitz, B ;
Tortai, JH ;
Bonifaci, N ;
Denat, A .
PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2004, :29-32
[32]   Thermogravimetric and differential scanning calorimetric analysis of natural fibres and polypropylene [J].
Wielage, B ;
Lampke, T ;
Marx, G ;
Nestler, K ;
Starke, D .
THERMOCHIMICA ACTA, 1999, 337 (1-2) :169-177
[33]  
Yamaguchi M., 1993, CIGRE