Eye lens radiation exposure to interventional cardiologists: a retrospective assessment of cumulative doses

被引:66
|
作者
Jacob, Sophie [1 ]
Donadille, Laurent [2 ]
Maccia, Carlo [3 ]
Bar, Olivier [4 ,5 ]
Boveda, Serge [6 ,7 ]
Laurier, Dominique [1 ]
Bernier, Marie-Odile [1 ]
机构
[1] Inst Radioprotect & Surete Nucl, PRP HOM, SRBE, Lab Epidemiol,LEPID, F-92262 Fontenay Aux Roses, France
[2] Inst Radioprotect & Surete Nucl, PRP HOM, SRBE, Lab Dosimetrie Rayonnements Ionisants, F-92262 Fontenay Aux Roses, France
[3] Ctr Assurance Qualite Applicat Technol Domaine Sa, Bourg La Reine, France
[4] Clin St Gatien, Serv Cardiol Intervent, Tours, France
[5] Soc Francaise Cardiol, Grp Atherome Cardiol Intervent, Tours, France
[6] Clin Pasteur, Dept Rythmol, Toulouse, France
[7] Soc Francaise Cardiol, Grp Rythmol Stimulat Cardiaque, Toulouse, France
关键词
RADIOFREQUENCY CATHETER ABLATION; CONTROLLED MECHANICAL PUMP; CARDIAC-CATHETERIZATION; CORONARY-ANGIOGRAPHY; PERSONNEL EXPOSURE; PATIENT; STAFF; IMPLANTATION; PHYSICIAN; ARTERIOGRAPHY;
D O I
10.1093/rpd/ncs116
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radiation dose to the eye lens is a crucial issue for interventional cardiologists (ICs) who are exposed during the procedures they perform. This paper presents a retrospective assessment of the cumulative eye lens doses of ICs enrolled in the OCLOC study for Occupational Cataracts and Lens Opacities in interventional Cardiology. Information on the workload in the catheterisation laboratory, radiation protection equipment, eye lens dose per procedure and dose reduction factors associated with eye-protective equipment were considered. For the 129 ICs at an average age of 51 who had worked for an average period of 22 years, the estimated cumulative eye lens dose ranged from 25 mSv to more than 1600 mSv; the meanSD was 423359 mSv. After several years of practice, without eye protection, ICs may exceed the new ICRP lifetime eye dose threshold of 500 mSv and be at high risk of developing early radiation-induced cataracts. Radiation protection equipment can reduce these doses and should be used routinely.
引用
收藏
页码:282 / 293
页数:12
相关论文
共 45 条
  • [31] DOSES TO OPERATORS DURING INTERVENTIONAL RADIOLOGY PROCEDURES: FOCUS ON EYE LENS AND EXTREMITY DOSIMETRY
    Koukorava, C.
    Carinou, E.
    Simantirakis, G.
    Vrachliotis, T. G.
    Archontakis, E.
    Tierris, C.
    Dimitriou, P.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 482 - 486
  • [32] Radiation exposure of interventional cardiologists during coronary angiography: evaluation by phantom measurement and computer simulation
    Roh, Younghoon
    Nam, Sora
    Lee, Bong-Ki
    Ryu, Dong-Ryeol
    Chun, Kwangjin
    Lee, Kyu-Sun
    Cho, Namho
    Yoon, Yongsu
    Park, Hyemin
    Cho, Byung-Ryul
    Kim, Jung Su
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (04) : 1279 - 1287
  • [33] Radiation exposure of interventional cardiologists during coronary angiography: evaluation by phantom measurement and computer simulation
    Younghoon Roh
    Sora Nam
    Bong-Ki Lee
    Dong-Ryeol Ryu
    Kwangjin Chun
    Kyu-Sun Lee
    Namho Cho
    Yongsu Yoon
    Hyemin Park
    Byung-Ryul Cho
    Jung Su Kim
    Physical and Engineering Sciences in Medicine, 2020, 43 : 1279 - 1287
  • [34] Radiation exposure of interventional cardiologists for different types of procedures in catheterization lab, is it more concern about extremities?
    Asgari, A.
    Parach, A. A.
    Daneshian, E.
    Nekoofar, Z.
    Bouzarjomehri, F.
    Mehrparvar, A. H.
    Mirmohammadi, S. J.
    Seyed-Hossaini, S. M.
    Dastmalchi, J.
    Emami, M.
    Andishmand, A.
    RADIOPROTECTION, 2020, 55 (03) : 187 - 194
  • [35] Radiation exposure of the radiologist's eye lens during CT-guided interventions
    Heusch, Philipp
    Kroepil, Patric
    Buchbender, Christian
    Aissa, Joel
    Lanzman, Rotem S.
    Heusner, Till A.
    Ewen, Klaus
    Antoch, Gerald
    Fuerst, Guenther
    ACTA RADIOLOGICA, 2014, 55 (01) : 86 - 90
  • [36] Ratios of Eye Lens and Hand Equivalent Doses with Whole-Body Effective Doses for Operators Performing Interventional Radiological Procedures
    Tsai, Wan-Chih
    Chu, Wei-Han
    Sheu, Rong-Jiun
    HEALTH PHYSICS, 2022, 123 (03): : 257 - 264
  • [37] Eye Lens Radiation Dose to Nurses during Cardiac Interventional Radiology: An Initial Study
    Yamada, Ayumi
    Haga, Yoshihiro
    Sota, Masahiro
    Abe, Mitsuya
    Kaga, Yuji
    Inaba, Yohei
    Suzuki, Masatoshi
    Tada, Norio
    Zuguchi, Masayuki
    Chida, Koichi
    DIAGNOSTICS, 2023, 13 (18)
  • [38] Eye lens radiation exposure of the medical staff performing interventional urology procedures with an over-couch X-ray tube
    Medici, S.
    Pitzschke, A.
    Cherbuin, N.
    Boldini, M.
    Sans-Merce, M.
    Damet, J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 43 : 140 - 147
  • [39] Influences of operator head posture and protective eyewear on eye lens doses in interventional radiology: A Monte Carlo Study
    Mao, Li
    Liu, Tianyu
    Caracappa, Peter F.
    Lin, Hui
    Gao, Yiming
    Dauer, Lawrence T.
    Xu, X. George
    MEDICAL PHYSICS, 2019, 46 (06) : 2744 - 2751
  • [40] Assessment of radiation doses and DNA damage in pediatric patients undergoing interventional procedures for vascular anomalies
    Ma, Ya
    Guo, Lei
    Fang, Lianying
    Hou, Dianjun
    Chen, Rui
    Wang, Xiaoshan
    Mao, Xuesong
    Zhao, Zihan
    Chen, Yingmin
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2023, 889