Eye lens radiation exposure to interventional cardiologists: a retrospective assessment of cumulative doses

被引:66
|
作者
Jacob, Sophie [1 ]
Donadille, Laurent [2 ]
Maccia, Carlo [3 ]
Bar, Olivier [4 ,5 ]
Boveda, Serge [6 ,7 ]
Laurier, Dominique [1 ]
Bernier, Marie-Odile [1 ]
机构
[1] Inst Radioprotect & Surete Nucl, PRP HOM, SRBE, Lab Epidemiol,LEPID, F-92262 Fontenay Aux Roses, France
[2] Inst Radioprotect & Surete Nucl, PRP HOM, SRBE, Lab Dosimetrie Rayonnements Ionisants, F-92262 Fontenay Aux Roses, France
[3] Ctr Assurance Qualite Applicat Technol Domaine Sa, Bourg La Reine, France
[4] Clin St Gatien, Serv Cardiol Intervent, Tours, France
[5] Soc Francaise Cardiol, Grp Atherome Cardiol Intervent, Tours, France
[6] Clin Pasteur, Dept Rythmol, Toulouse, France
[7] Soc Francaise Cardiol, Grp Rythmol Stimulat Cardiaque, Toulouse, France
关键词
RADIOFREQUENCY CATHETER ABLATION; CONTROLLED MECHANICAL PUMP; CARDIAC-CATHETERIZATION; CORONARY-ANGIOGRAPHY; PERSONNEL EXPOSURE; PATIENT; STAFF; IMPLANTATION; PHYSICIAN; ARTERIOGRAPHY;
D O I
10.1093/rpd/ncs116
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radiation dose to the eye lens is a crucial issue for interventional cardiologists (ICs) who are exposed during the procedures they perform. This paper presents a retrospective assessment of the cumulative eye lens doses of ICs enrolled in the OCLOC study for Occupational Cataracts and Lens Opacities in interventional Cardiology. Information on the workload in the catheterisation laboratory, radiation protection equipment, eye lens dose per procedure and dose reduction factors associated with eye-protective equipment were considered. For the 129 ICs at an average age of 51 who had worked for an average period of 22 years, the estimated cumulative eye lens dose ranged from 25 mSv to more than 1600 mSv; the meanSD was 423359 mSv. After several years of practice, without eye protection, ICs may exceed the new ICRP lifetime eye dose threshold of 500 mSv and be at high risk of developing early radiation-induced cataracts. Radiation protection equipment can reduce these doses and should be used routinely.
引用
收藏
页码:282 / 293
页数:12
相关论文
共 45 条
  • [11] A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists
    Farah, J.
    Struelens, L.
    Dabin, J.
    Koukorava, C.
    Donadille, L.
    Jacob, S.
    Schnelzer, M.
    Auvinen, A.
    Vanhavere, F.
    Clairand, I.
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (04) : 561 - 569
  • [12] Assessment of dosimetric approaches in evaluating radiation exposure for interventional cardiologists in Sri Lanka
    Wickramasinghe, Sachini Udara
    Ramanathan, Vijitha
    Sarasanandarajah, Sivananthan
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 258 - 268
  • [13] Radiation exposure and the risk of cancer for interventional cardiologists and electrophysiologists
    Knuuti, Juhani
    Jarvinen, Jukka
    EUROPEAN HEART JOURNAL, 2014, 35 (10) : 603 - 604
  • [14] HAND AND EYE LENS DOSES TO CARDIOLOGIST IN INTERVENTIONAL RADIOLOGY
    Repse, Kristina
    Gedvilas, Marius
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 137 - 139
  • [15] Interventional cardiology: Radiation exposure assessment and areas delineation
    Abou Anoma, G.
    Michel, X.
    Breton, D.
    Schoulz, D.
    Pennacino, I.
    Amabile, J. -C.
    Laroche, P.
    ARCHIVES DES MALADIES PROFESSIONNELLES ET DE L ENVIRONNEMENT, 2012, 73 (06) : 849 - 859
  • [16] Patient cumulative radiation exposure in interventional cardiology
    Bernier, M-O
    Jacob, S.
    Maccia, C.
    Bar, O.
    Catelinois, O.
    Blanchard, D.
    Laurier, D.
    RADIOPROTECTION, 2012, 47 (01) : 93 - 103
  • [17] Impact of Simulation-Based Training on Radiation Exposure of Young Interventional Cardiologists
    Popovic, Batric
    Varlot, Jeanne
    Girard-Bertrand, Barbara
    Basile, Jean Louis
    Thouvenot, Christophe
    Fay, Renaud
    Villani, Nicolas
    Tran, Nguyen
    Camenzind, Edoardo
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 181 : 25 - 31
  • [18] Measurement of occupational doses of ionising radiation to the lens of the eyes of interventional radiologists
    Higgins, Anthony
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (01) : 74 - 92
  • [19] Reduction in exposure of interventional cardiologists to ionising radiation over a 10-year period
    Faroux, Laurent
    Blanpain, Thierry
    Nazeyrollas, Pierre
    Tassan-Mangina, Sophie
    Heroguelle, Virginie
    Tourneux, Christophe
    Baudin, Florian
    Metz, Damien
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 259 : 57 - 59
  • [20] Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures
    Akahane, Masaaki
    Yoshioka, Naoki
    Kiryu, Shigeru
    INTERVENTIONAL RADIOLOGY, 2022, 7 (02) : 44 - 48