What is inverse-geometry CT?

被引:7
作者
Schmidt, Taly Gilat [1 ]
机构
[1] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53201 USA
关键词
Volumetric CT; Inverse geometry; CT systems; X-RAY SCATTER; SYSTEM; TOMOGRAPHY; PROTOTYPE; MAGNITUDE;
D O I
10.1016/j.jcct.2011.04.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Inverse-geometry computed tomography (IGCT) systems are being developed to provide improved volumetric imaging. In conventional multislice CT systems, x-rays are emitted from a small area and irradiate a large-area detector. In an IGCT system, x-ray sources are distributed over a large area, with each beam irradiating a small-area detector. Therefore, in the inverse geometry, a series of narrow x-ray beams are switched on and off while the gantry rotates. In conventional CT geometry, cone-beam and scatter artifacts increase with the imaged volume thickness. An inverse geometry may be less susceptible to scatter effects, because only a fraction of the field of view is irradiated at one time. The distributed source in the inverse geometry potentially improves sampling, leading to reduced cone-beam artifacts. In the inverse geometry, the tube current may be adjusted separately for each source location, which potentially reduces dose. Multiple IGCT prototypes have been constructed and tested on phantoms. A gantry-based IGCT system with one-second gantry rotation was developed, and images of phantoms and small animals were successfully acquired. Clinical feasibility with acceptable noise levels and scan times has not yet been shown. Overall, results from prototype systems suggest that the inverse geometry will enable imaging of a thick volume (similar to 16 cm) while potentially reducing cone-beam artifacts, scatter effects, and radiation dose. The magnitude of these benefits will depend on the specific IGCT implementation and need to be quantified relative to comparable multislice scanners. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:145 / 148
页数:4
相关论文
共 12 条
  • [1] Albert TM, 1993, P SOC PHOTO-OPT INS, P12
  • [2] [Anonymous], P SPIE
  • [3] Simulated scatter performance of an inverse-geometry dedicated breast CT system
    Bhagtani, Reema
    Schmidt, Taly Gilat
    [J]. MEDICAL PHYSICS, 2009, 36 (03) : 788 - 796
  • [4] Multi-source inverse-geometry CT: from system concept to research prototype
    De Man, Bruno
    Caiafa, Antonio
    Cao, Yang
    Frutschy, Kristopher
    Harrison, Daniel
    Inzinna, Lou
    Longtin, Randy
    Neculaes, Bogdan
    Reynolds, Joseph
    Roy, Jaydeep
    Short, Jonathan
    Uribe, Jorge
    Waters, William
    Yin, Zhye
    Zhang, Xi
    Zou, Yun
    Senzig, Bob
    Baek, Jongduk
    Pelc, Norbert
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3531 - +
  • [5] Magnitude and effects of x-ray scatter in a 256-slice CT scanner
    Endo, Masahiro
    Mori, Shinichiro
    Tsunoo, Takanori
    Miyazaki, Hiroaki
    [J]. MEDICAL PHYSICS, 2006, 33 (09) : 3359 - 3368
  • [6] Reverse geometry X-ray imaging
    Malglaive, F.
    Albert, R. D.
    [J]. INSIGHT, 2009, 51 (02) : 66 - 68
  • [7] Inverse-geometry volumetric CT system with multiple detector arrays for wide field-of-view imaging
    Mazin, Samuel R.
    Star-Lack, Josh
    Bennett, N. Robert
    Pelc, Norbert J.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2133 - 2142
  • [8] A prototype table-top inverse-geometry volumetric CT system
    Schmidt, Taly Gilat
    Star-Lack, Josh
    Bennett, N. Robert
    Mazin, Samuel R.
    Solomon, Edward G.
    Fahrig, Rebecca
    Pelc, Norbert J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1867 - 1878
  • [9] An inverse-geometry volumetric CT system with a large-area scanned source: A feasibility study
    Schmidt, TG
    Fahrig, R
    Pelc, NJ
    Solomon, EG
    [J]. MEDICAL PHYSICS, 2004, 31 (09) : 2623 - 2627
  • [10] Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
    Siewerdsen, JH
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 2001, 28 (02) : 220 - 231