Trace isotope analysis of Ricinus communis seed core for provenance determination by laser ablation-ICP-MS

被引:2
|
作者
Bagas, Christina K. [1 ]
Scadding, Rachel L. [2 ]
Scadding, Cameron J. [2 ]
Watling, R. John [2 ]
Roberts, Warren [1 ]
Ovenden, Simon P. B. [1 ]
机构
[1] Def Sci & Technol Grp, 506 Lorimer St, Fishermans Bend, Vic 3207, Australia
[2] TSW Analyt Pty Ltd, 2-27 Clark Court, Bibra Lake, WA 6163, Australia
关键词
Ricinus communis; Laser ablation-ICP-MS; Multivariate statistical analysis; Trace isotope; Provenance; Ricin; PLASMA-MASS SPECTROMETRY; METAL HYPERACCUMULATION; PURIFIED EXTRACTS; IDENTIFICATION; CRUDE; METABOLOME; CULTIVAR; PLANTS; SITE; TIME;
D O I
10.1016/j.forsciint.2016.11.029
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The castor bean plant, Ricinus communis, grows wild throughout many regions of Australia. The seeds of the plant contain the schedule 1 chemical agent ricin, a type II ribosomal inhibiting protein. Currently there are limited analytical techniques that can be applied in analysis of the seeds to establish attribution. In this study, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for the analysis of seeds collected from 68 plants across 38 locations around Australia. Of the 92 elemental isotopes measured, fifteen (Mg-24, Al-27, Ca-44, Cr-53, Mn-55, Fe-57, Ni-60, Cu-65, Zn-66, As-75, Rb-85, Sr-88, Mo-98, Ba-138 and Hg-202) yielded data that were relevant to all collection sites. Data were further analysed using multivariate statistical analysis which facilitated the potential for the identification of unique provenance isotopes. Furthermore, this analysis indicated that Co-59 was present at significant levels in Victorian and Sydney specimens only. Crown Copyright (C) 2016 Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [1] Trace element distribution in marine microplastics using laser ablation-ICP-MS
    El Hadri, Hind
    Gigault, Julien
    Mounicou, Sandra
    Grassl, Bruno
    Reynaud, Stephanie
    MARINE POLLUTION BULLETIN, 2020, 160 (160)
  • [2] Precise elemental and isotope ratio determination by simultaneous solution nebulization and laser ablation-ICP-MS: application to U-Pb geochronology
    Horn, I
    Rudnick, RL
    McDonough, WF
    CHEMICAL GEOLOGY, 2000, 164 (3-4) : 281 - 301
  • [3] Experimental assessment of a large sample cell for laser ablation-ICP-MS, and its application to sediment core micro-analysis
    Carugati, Gabriele
    Rauch, Sebastien
    Kylander, Malin E.
    MICROCHIMICA ACTA, 2010, 170 (1-2) : 39 - 45
  • [4] Simultaneous Determination of Size and Position of Silver and Gold Nanoparticles in Onion Cells using Laser Ablation-ICP-MS
    Yamashita, Shuji
    Yoshikuni, Yukihisa
    Obayashi, Hideyuki
    Suzuki, Toshihiro
    Green, Damon
    Hirata, Takafumi
    ANALYTICAL CHEMISTRY, 2019, 91 (07) : 4544 - 4551
  • [5] Determination of major to trace elements in metallic materials based on the solid mixing calibration method using multiple spot-laser ablation-ICP-MS
    Makino, Yoshiki
    Kuroki, Yasuo
    Hirata, Takafumi
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (09) : 1794 - 1799
  • [6] Quantitative Measurement of Multiple Elements in Micro-Quantities of Crude Oil Using In Situ Analysis by Laser Ablation-ICP-MS
    Chbani, Malika
    Boiron, Marie-Christine
    Peiffert, Chantal
    Marin, Jerome
    Lorgeoux, Catherine
    Michels, Raymond
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024, 48 (04) : 823 - 835
  • [7] Characterization of Accumulation of Rare Earth Elements in Athyrium yokoscense by Laser Ablation-ICP-MS
    Miyoshi, Kana
    Abe, Yoshinari
    Takaku, Yuichi
    Nakai, Izumi
    BUNSEKI KAGAKU, 2015, 64 (08) : 617 - 624
  • [8] Mapping of macro and micro elements in the leaves of sunflower (Helianthus annuus) by Laser Ablation-ICP-MS
    Koetschau, A.
    Buechel, G.
    Einax, J. W.
    Fischer, C.
    von Tuempling, W.
    Merten, D.
    MICROCHEMICAL JOURNAL, 2013, 110 : 783 - 789
  • [9] An analysis of long-distance root to leaf transport of lead in Pisum sativum plants by laser ablation-ICP-MS
    Hanc, Anetta
    Baralkiewicz, Danuta
    Piechalak, Aneta
    Tomaszewska, Barbara
    Wagner, Barbara
    Bulska, Ewa
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (8-12) : 651 - 659
  • [10] Precise elemental and isotope ratio determination by simultaneous solution nebulization and laser ablation-ICP-MS: application to U-Pb geochronology (vol 164, pg 283, 2000)
    Horn, I
    Rudnick, RL
    McDonough, WF
    CHEMICAL GEOLOGY, 2000, 167 (3-4) : 403 - +