Real-time monitoring of luminal esophageal temperature during left atrial radiofrequency catheter ablation for atrial fibrillation: Observations about esophageal heating during ablation at the pulmonary vein ostia and posterior left atrium

被引:55
|
作者
Perzanowski, C [1 ]
Teplitsky, L [1 ]
Hranitzky, PM [1 ]
Bahnson, TD [1 ]
机构
[1] Duke Univ, Med Ctr, Clin Cardiac Electrophysiol Fellow Program, Arrhythmia Alblat Serv,Sect Cardiac Electrophysio, Durham, NC 27710 USA
关键词
atrial fibrillation; catheter ablation; radiofrequency ablation; esophagus; atrioesophageal fistula;
D O I
10.1111/j.1540-8167.2005.00333.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Left atrial radiofrequency catheter ablation (RFA) is gaining acceptance as treatment for drug-refractory atrial fibrillation (AF). This therapy has been associated with esophageal injury and atrioesophageal fistula formation causing death. Methods: We describe 3 patients undergoing catheter ablation for AF during real-time monitoring of luminal esophageal temperature. Results: We observed heating of the esophagus during short duration low power RFA, at either the left or right pulmonary vein ostia. Cryoablation at the pulmonary vein ostium in one patient resulted in esophageal cooling. Furthermore, we observed that fluoroscopic localization of the ablation catheter at a site apparently distant from the esophagus is not adequate to assure avoidance of ablation-induced esophageal heating. Conclusions: Real-time monitoring of luminal esophageal position and temperature is feasible, enhances recognition of esophageal heating, and may add useful information beyond that provided by fluoroscopic assessment of esophageal position. There is a potential role for esophageal monitoring to help avoid thermal injury to the esophagus during catheter ablation for atrial fibrillation.
引用
收藏
页码:166 / 170
页数:5
相关论文
共 50 条
  • [1] Luminal Esophageal Temperature Monitoring for the Prevention of Esophageal Injury During Left Atrial Ablation: LET It Be?
    Tzou, Wendy S.
    Russo, Andrea M.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (09) : 965 - 967
  • [2] Esophageal temperature monitoring during radiofrequency ablation of atrial fibrillation
    Redfearn, DP
    Trim, GM
    Skanes, AC
    Petrellis, B
    Krahn, AD
    Yee, R
    Klein, GJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (06) : 589 - 593
  • [3] Left atrial-esophageal fistula following radiofrequency catheter ablation of atrial fibrillation
    Scanavacca, MI
    Avila, AD
    Parga, J
    Sosa, E
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (08) : 960 - 962
  • [4] Luminal esophageal temperature monitoring to reduce esophageal thermal injury during catheter ablation for atrial fibrillation: A review
    Kadado, Anis John
    Akar, Joseph G.
    Hummel, James R.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2019, 29 (05) : 264 - 271
  • [5] Intracardiac Ultrasound for Esophageal Anatomic Assessment and Localization During Left Atrial Ablation for Atrial Fibrillation
    Bunch, T. Jared
    May, Heidi T.
    Crandall, Brian G.
    Weiss, J. Peter
    Bair, Tami L.
    Osborn, Jeffrey S.
    Anderson, Jeffrey L.
    Muhlestein, Joseph B.
    Lappe, Donald L.
    Johnson, David L.
    Day, John D.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (01) : 33 - 39
  • [6] The influence of cryoballoon manipulation on luminal esophageal temperature during ablation for atrial fibrillation
    Chen, Hongwu
    Liu, Qiang
    Shehata, Michael
    Ma, Wei
    Xu, Jing
    Cao, Jianing
    Cingolani, Eugenio
    Ehdaie, Ashkan
    Jiang, Chenyang
    Chen, Minglong
    Chugh, Sumeet S.
    Wang, Xunzhang
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (09): : 1169 - 1174
  • [7] Mechanical Esophageal Displacement During Catheter Ablation for Atrial Fibrillation
    Koruth, Jacob S.
    Reddy, Vivek Y.
    Miller, Marc A.
    Patel, Kalpesh K.
    Coffey, James O.
    Fischer, Avi
    Gomes, J. Anthony
    Dukkipati, Srinivas
    D'Avila, Andre
    Mittnacht, Alexander
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (02) : 147 - 154
  • [8] Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
    Zagrodzky, Jason
    Gallagher, Mark M.
    Leung, Lisa W. M.
    Sharkoski, Tiffany
    Santangeli, Pasquale
    Tschabrunn, Cory
    Guerra, Jose M.
    Campos, Bieito
    MacGregor, John
    Hayat, Jamal
    Clark, Brad
    Mazur, Alex
    Feher, Marcel
    Arnold, Martin
    Metzl, Mark
    Nazari, Jose
    Kulstad, Erik
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (157):
  • [9] Left Atrial-Esophageal Fistula Repair after Radiofrequency Catheter Ablation for Atrial Fibrillation
    Velotta, Jeffrey B.
    Vasquez, Charles R.
    Bolman, Ralph M.
    Dasilva, Marcelo C.
    THORACIC AND CARDIOVASCULAR SURGEON REPORTS, 2013, 2 (01) : 13 - 15
  • [10] Esophageal imaging and strategies for avoiding injury during left atrial ablation for atrial fibrillation
    Ren, Jian-Fang
    Lin, David
    Marchlinski, Francis E.
    Callans, David J.
    Patel, Vickas
    HEART RHYTHM, 2006, 3 (10) : 1156 - 1161