Simulation of stent deployment in a realistic human coronary artery

被引:95
作者
Gijsen, Frank J. H. [1 ]
Migliavacca, Francesco [2 ]
Schievano, Silvia [3 ,4 ]
Socci, Laura [2 ]
Petrini, Lorenza [2 ]
Thury, Attila [1 ]
Wentzel, Jolanda J. [1 ]
van der Steen, Anton F. W. [1 ]
Serruys, Patrick W. S. [1 ]
Dubini, Gabriele [2 ]
机构
[1] Erasmus MC, Thoraxctr Ee2322, Dept Biomed Engn, NL-3000 CA Rotterdam, Netherlands
[2] Politecn Milan, Dept Struct Engn, Lab Biol Struct Mech, I-20133 Milan, Italy
[3] Great Ormond St Hosp Sick Children, London WC1N 3JH, England
[4] UCL, Inst Child Hlth, Cardiothorac Unit, London, England
关键词
D O I
10.1186/1475-925X-7-23
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The process of restenosis after a stenting procedure is related to local biomechanical environment. Arterial wall stresses caused by the interaction of the stent with the vascular wall and possibly stress induced stent strut fracture are two important parameters. The knowledge of these parameters after stent deployment in a patient derived 3D reconstruction of a diseased coronary artery might give insights in the understanding of the process of restenosis. Methods: 3D reconstruction of a mildly stenosed coronary artery was carried out based on a combination of biplane angiography and intravascular ultrasound. Finite element method computations were performed to simulate the deployment of a stent inside the reconstructed coronary artery model at inflation pressure of 1.0 MPa. Strut thickness of the stent was varied to investigate stresses in the stent and the vessel wall. Results: Deformed configurations, pressure-lumen area relationship and stress distribution in the arterial wall and stent struts were studied. The simulations show how the stent pushes the arterial wall towards the outside allowing the expansion of the occluded artery. Higher stresses in the arterial wall are present behind the stent struts and in regions where the arterial wall was thin. Values of 200 MPa for the peak stresses in the stent strut were detected near the connecting parts between the stent struts, and they were only just below the fatigue stress. Decreasing strut thickness might reduce arterial damage without increasing stresses in the struts significantly. Conclusion: The method presented in this paper can be used to predict stresses in the stent struts and the vessel wall, and thus evaluate whether a specific stent design is optimal for a specific patient.
引用
收藏
页数:11
相关论文
共 33 条
[1]  
Auricchio F., 2001, COMPUT METHOD BIOMEC, V4, P249, DOI DOI 10.1080/10255840108908007
[2]   Intramural stress increases exponentially with stent diameter: A stress threshold for neointimal hyperplasia [J].
Ballyk, Peter D. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (07) :1139-1145
[3]   Effects of stent design parameters on normal artery wall mechanics [J].
Bedoya, Julian ;
Meyer, Clark A. ;
Timmins, Lucas H. ;
Moreno, Michael R. ;
Moore, James E., Jr. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (05) :757-765
[4]  
De Beule M, 2006, Technol Health Care, V14, P233
[5]   Mechanical behaviour modelling of balloon-expandable stents [J].
Dumoulin, C ;
Cochelin, B .
JOURNAL OF BIOMECHANICS, 2000, 33 (11) :1461-1470
[6]   Stented artery flow patterns and their effects on the artery wall [J].
Duraiswamy, Nandim ;
Schoephoerster, Richard T. ;
Moreno, Michael R. ;
Moore, James E., Jr. .
ANNUAL REVIEW OF FLUID MECHANICS, 2007, 39 :357-382
[7]   Pathobiologic responses to stenting [J].
Edelman, ER ;
Rogers, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (7A) :4E-6E
[8]   Modeling plaque fissuring and dissection during balloon angioplasty intervention [J].
Gasser, T. Christian ;
Holzapfel, Gerhard A. .
ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (05) :711-723
[9]   The finite element analysis of stresses in atherosclerotic arteries during balloon angioplasty [J].
Gourisankaran, V ;
Sharma, MG .
CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 2000, 28 (1-2) :47-51
[10]  
Green A.E., 1968, Theoretical Elasticity