Decellularized Human Dermis to Treat Massive Rotator Cuff Tears: In Vitro Evaluations

被引:20
作者
Fini, Milena [1 ,2 ]
Bondioli, Elena [3 ,4 ]
Castagna, Alessandro [5 ]
Torricelli, Paola [1 ,2 ]
Giavaresi, Gianluca [1 ,2 ]
Rotini, Roberto [6 ]
Marinelli, Alessandro [6 ]
Guerra, Enrico [6 ]
Orlandi, Catuscia [3 ,4 ]
Carboni, Andrea [3 ,4 ]
Aiti, Annalisa [3 ,4 ]
Benedettini, Elisa [3 ,4 ]
Giardino, Roberto [2 ]
Melandri, Davide [3 ,4 ]
机构
[1] Rizzoli Orthopaed Inst, Lab Preclin & Surg Studies, I-40136 Bologna, Italy
[2] Dept Rizzoli RIT, Lab Biocompatibil Technol Innovat & Adv Therapies, Bologna, Italy
[3] Bufalini Hosp, Burn Intens Care Unit, Cesena, Italy
[4] Bufalini Hosp, Reg Emilia Romagna Skin Bank, Cesena, Italy
[5] IRCCS Clin Inst Humanitas, Milan, Italy
[6] Rizzoli Orthopaed Inst, Shoulder & Elbow Surg Unit, I-40136 Bologna, Italy
关键词
tenocytes; tendons; decellularization technique; dermis; in vitro microwound model; SMALL-INTESTINE SUBMUCOSA; BIOMECHANICAL EVALUATION; BIORESORBABLE SCAFFOLD; GAMMA-IRRADIATION; SURGICAL REPAIR; TENDON REPAIR; TISSUE MATRIX; ANIMAL-MODEL; FELT GRAFT; AUGMENTATION;
D O I
10.3109/03008207.2011.649929
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Interest is increasing in biological scaffolds for tissue regeneration such as extracellular matrix membranes, developed through soft tissue decellularization. Extracellular matrix membranes were developed to heal different tendon and soft tissue lesions that are very frequent in the general population with high health-care costs and patient morbidity. The aim of this research was to evaluate a human dermal matrix (HDM) decellularized by a chemico-physical method. A primary culture of rat tenocytes was performed: tenocytes were seeded on HDM samples and on polystyrene wells as controls (CTR). Cell viability and synthetic activity were evaluated at 3 and 7 days. An in vitro microwound model was used to evaluate HDM bioactivity: after tenocyte expansion, artificial wounds were created, HDM extracts were added, and closure time and decorin synthesis were monitored histomorphometrically at 1, 4, 24, and 72 hr. A significant higher amount of collagen I was observed when cells were cultured on HDM in comparison with that on CTR (3 days: p < 0.0001; 7 days: p < 0.05). In HDM group, fibronectin synthesis was significantly higher at both experimental times (p < 0.0001). At 3 days, proteoglycans and transforming growth factor-beta 1 releases were significantly higher on HDM (p < 0.0001 and p < 0.005, respectively). The artificial microwound closure time and decorin expression were significantly enhanced by the addition of 50% HDM extract (p < 0.05). In vitro data showed that the decellularization technique enabled the development of a matrix with adequate biological and biomechanical properties.
引用
收藏
页码:298 / 306
页数:9
相关论文
共 47 条
  • [1] Tensile properties and biological response of poly(L-lactic acid) felt graft: An experimental trial for Rotator-Cuff reconstruction
    Aoki, M
    Miyamoto, S
    Okamura, K
    Yamashita, T
    Ikada, Y
    Matsuda, S
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 71B (02) : 252 - 259
  • [2] Reconstruction of massive rotator cuff lesions with a synthetic interposition graft: a prospective study of 41 patients
    Audenaert, E
    Van Nuffel, J
    Schepens, A
    Verhelst, M
    Verdonk, R
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (04) : 360 - 364
  • [3] Commercially available extracellular matrix materials for rotator cuff repairs: State of the art and future trends
    Aurora, Amit
    McCarron, Jesse
    Iannotti, Joseph P.
    Derwin, Kathleen
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (05) : 171S - 178S
  • [4] An assessment of porcine dermal xenograft as an augmentation graft in the treatment of extensive rotator cuff tears
    Badhe, Sachin P.
    Lawrence, Tom M.
    Smith, F. D.
    Lunn, P. G.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (01) : 35S - 39S
  • [5] Surgical repair of the rotator cuff: a biomechanical evaluation of different tendon grasping and bone suture fixation techniques
    Baleani, M
    Schrader, S
    Veronesi, CA
    Rotini, R
    Giardino, R
    Toni, A
    [J]. CLINICAL BIOMECHANICS, 2003, 18 (08) : 721 - 729
  • [6] Tendon augmentation grafts: Biomechanical failure loads and failure patterns
    Barber, F. Alan
    Herbert, Morley A.
    Coons, David A.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (05) : 534 - 538
  • [7] Arthroscopic replacement of massive, irreparable rotator cuff tears using a GraftJacket allograft: Technique and preliminary results
    Bond, James L.
    Dopirak, Ryan M.
    Higgins, Jason
    Burns, Joseph
    Snyder, Stephen J.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (04) : 403 - 409
  • [8] Low-Level Laser Irradiation Promotes Cell Proliferation and mRNA Expression of Type I Collagen and Decorin in Porcine Achilles Tendon Fibroblasts In Vitro
    Chen, Chia-Hsin
    Tsai, Jin-Lian
    Wang, Yan-Hsiung
    Lee, Chia-Ling
    Chen, June-Kai
    Huang, Mao-Hsiung
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (05) : 646 - 650
  • [9] Strategies in Biologic Augmentation of Rotator Cuff Repair: A Review
    Cheung, Emilie V.
    Silverio, Luz
    Sperling, John W.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (06) : 1476 - 1484
  • [10] Biocompatibility of a polymer patch for rotator cuff repair
    Cole, Brian J.
    Gomoll, Andreas H.
    Yanke, Adam
    Pylawka, Tamara
    Lewis, Paul
    MacGillivray, John D.
    Williams, James M.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (05) : 632 - 637