Fast generation of digitally reconstructed radiographs using attenuation fields with application to 2D-3D image registration

被引:106
作者
Russakoff, DB
Rohlfing, T
Mori, K
Rueckert, D
Ho, A
Adler, JR
Maurer, CR
机构
[1] Stanford Univ, Dept Comp Sci, Stanford, CA 94305 USA
[2] SRI Int, Program Neurosci, Menlo Pk, CA 94025 USA
[3] Nagoya Univ, Grad Sch Informat Sci, Nagoya, Aichi 4648603, Japan
[4] Univ London Imperial Coll Sci & Technol, Dept Comp, London SW7 2AZ, England
[5] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[6] Stanford Univ, Dept Neurosurg, Stanford, CA 94305 USA
[7] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[8] Stanford Univ, Dept Neurosurg, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
digitally reconstructed radiographs; image-guided therapy; intensity-based 2D-3D image registration; light fields; FLUOROSCOPIC X-RAY; RIGID REGISTRATION; CT IMAGES; 3-DIMENSIONAL REGISTRATION; MUTUAL-INFORMATION; ALGORITHM;
D O I
10.1109/TMI.2005.856749
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Generation of digitally reconstructed radiographs (DRRs) is computationally expensive and is typically the rate-limiting step in the execution time of intensity-based two-dimensional to three-dimensional (2D-3D) registration algorithms. We address this computational issue by extending the technique of light field rendering from the computer graphics community. The extension of light fields, which we call attenuation fields (AFs), allows most of the DRR computation to be performed in a preprocessing step; after this precomputation step, DRRs can be generated substantially faster than with conventional ray casting. We derive expressions for the physical sizes of the two planes of an AF necessary to generate DRRs for a given X-ray camera geometry and all possible object motion within a specified range. Because an AF is a ray-based data structure, it is substantially more memory efficient than a huge table of precomputed DRRs because it eliminates the redundancy of replicated rays. Nonetheless, an AF can require substantial memory, which we address by compressing it using vector quantization. We compare DRRs generated using AFs (AF-DRRs) to those generated using ray casting (RC-DRRs) for a typical C-arm geometry and computed tomography images of several anatomic regions. They are quantitatively very similar: the median peak signal-to-noise ratio of AF-DRRs versus RC-DRRs is greater than 43 dB in all cases. We perform intensity-based 2D-3D registration using AF-DRRs and RC-DRRs and evaluate registration accuracy using gold-standard clinical spine image data from four patients. The registration accuracy and robustness of the two methods is virtually identical whereas the execution speed using AF-DRRs is an order of magnitude faster.
引用
收藏
页码:1441 / 1454
页数:14
相关论文
共 51 条
  • [1] Image-guided robotic radiosurgery
    Adler, JR
    Murphy, MJ
    Chang, SD
    Hancock, SL
    [J]. NEUROSURGERY, 1999, 44 (06) : 1299 - 1306
  • [2] LEAST-SQUARES FITTING OF 2 3-D POINT SETS
    ARUN, KS
    HUANG, TS
    BLOSTEIN, SD
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) : 699 - 700
  • [3] Entropy-based dual-portal-to-3-DCT registration incorporating pixel correlation
    Bansal, R
    Staib, LH
    Chen, Z
    Rangarajan, A
    Knisely, J
    Nath, R
    Duncan, JS
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (01) : 29 - 49
  • [4] 3-DIMENSIONAL VERIFICATION OF PATIENT PLACEMENT DURING RADIOTHERAPY USING PORTAL IMAGES
    BIJHOLD, J
    [J]. MEDICAL PHYSICS, 1993, 20 (02) : 347 - 356
  • [5] A faster method for 3D/2D medical image registration - a simulation study
    Birkfellner, W
    Wirth, J
    Burgstaller, W
    Baumann, B
    Staedele, H
    Hammer, B
    Gellrich, NC
    Jacob, AL
    Regazzoni, P
    Messmer, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (16) : 2665 - 2679
  • [6] BIRKFELLNER W, 2005, IN PRESS PHYS MED BI
  • [7] Breeuwer M, 1998, IEEE Trans Inf Technol Biomed, V2, P156, DOI 10.1109/4233.735780
  • [8] Registration of planar film radiographs with computed tomography
    Brown, LMG
    Boult, TE
    [J]. PROCEEDINGS OF THE IEEE WORKSHOP ON MATHEMATICAL METHODS IN BIOMEDICAL IMAGE ANALYSIS, 1996, : 42 - 51
  • [9] Cabral B., 1994, P 1994 S VOLUME VISU, P91, DOI DOI 10.1145/197938.197972
  • [10] Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data
    Gilhuijs, KGA
    vandeVen, PJH
    vanHerk, M
    [J]. MEDICAL PHYSICS, 1996, 23 (03) : 389 - 399