Development and Validation of a Computationally Efficient Finite Element Model of the Human Lumbar Spine: Application to Disc Degeneration

被引:10
作者
Warren, Justin M. [1 ]
Mazzoleni, Andre P. [1 ]
Hey, Lloyd A. [2 ]
机构
[1] North Carolina State Univ, Dept Mech & Aerosp Engn, Raleigh, NC USA
[2] Hey Clin Scoliosis & Spine Surg, 3320 Wake Forest Rd,Suite 450, Raleigh, NC 27609 USA
关键词
finite element method; lumbar spine; validation; disc degeneration; efficient; BIOMECHANICAL ANALYSIS; INTERBODY FUSION; STRESS-ANALYSIS; ADJACENT; POSTERIOR; FOLLOWER; VIBRATION; BEHAVIOR; LOADS;
D O I
10.14444/7066
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: This study develops and validates an accurate, computationally efficient, 3-dimensional finite element model (FEM) of the human lumbar spine. Advantages of this simplified model are shown by its application to a disc degeneration study that we demonstrate is completed in one-sixth the time required when using more complicated computed tomography (CT) scan-based models. Methods: An osseoligamentous FEM of the L1-L5 spine is developed using simple shapes based on average anatomical dimensions of key features of the spine rather than CT scan images. Pure moments of 7.5 Nm and a compressive follower load of 1000 N are individually applied to the L1 vertebra. Validation is achieved by comparing rotations and intradiscal pressures to other widely accepted FEMs and in vitro studies. Then degenerative disc properties are modeled and rotations calculated. Required computation times are compared between the model presented in this paper and other models developed using CT scans. Results: For the validation study, parameter values for a healthy spine were used with the loading conditions described above. Total L1-L5 rotations for flexion, extension, lateral bending, and axial rotation under pure moment loading were calculated as 20.3 degrees, 10.7 degrees, 19.7 degrees, and 10.3 degrees, respectively, and under a compressive follower load, maximum intradiscal pressures were calculated as 0.68 MPa. These values compare favorably with the data used for validation. When studying the effects of disc degeneration, the affected segment is shown to experience decreases in rotations during flexion, extension, and lateral bending (24%-56%), while rotations are shown to increase during axial rotation (14%-40%). Adjacent levels realize relatively minor changes in rotation (1%-6%). This parametric study required 17.5 hours of computation time compared to more than 4 days required if utilizing typical published CT scan-based models, illustrating one of the primary advantages of the model presented in this article. Conclusions: The FEM presented in this article produces a biomechanical response comparable to widely accepted, complex, CT scan-based models and in vitro studies while requiring much shorter computation times. This makes the model ideal for conducting parametric studies of spinal pathologies and spinal correction techniques.
引用
收藏
页码:502 / 510
页数:9
相关论文
共 48 条
[1]   A combined passive and active musculoskeletal model study to estimate L4-L5 load sharing [J].
Azari, F. ;
Arjmand, N. ;
Shirazi-Adl, A. ;
Rahimi-Moghaddam, T. .
JOURNAL OF BIOMECHANICS, 2018, 70 :157-165
[2]   Effect of disc degeneration on the mechanical behavior of the human lumbar spine: a probabilistic finite element study [J].
Bashkuev, Maxim ;
Reitmaier, Sandra ;
Schmidt, Hendrik .
SPINE JOURNAL, 2018, 18 (10) :1910-1920
[3]   Vertebral Bodies or Discs: Which Contributes More to Human-like Lumbar Lordosis? [J].
Been, Ella ;
Barash, Alon ;
Marom, Assaf ;
Kramer, Patricia A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (07) :1822-1829
[4]   FINITE-ELEMENT STRESS ANALYSIS OF AN INTERVERTEBRAL-DISK [J].
BELYTSCHKO, T ;
KULAK, RF ;
SCHULTZ, AB ;
GALANTE, JO .
JOURNAL OF BIOMECHANICS, 1974, 7 (03) :277-285
[5]   Comparative anatomical dimensions of the complete human and porcine spine [J].
Busscher, Iris ;
Ploegmakers, Joris J. W. ;
Verkerke, Gijsbertus J. ;
Veldhuizen, Albert G. .
EUROPEAN SPINE JOURNAL, 2010, 19 (07) :1104-1114
[6]   Interbody Spacer Material Properties and Design Conformity for Reducing Subsidence During Lumbar Interbody Fusion [J].
Chatham, Lillian S. ;
Patel, Vikas V. ;
Yakacki, Christopher M. ;
Carpenter, R. Dana .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (05)
[7]  
Chen CS, 2001, MED ENG PHYS, V23, P483
[8]  
Cobetto N, 2017, SCOLIOSIS SPINAL DIS, V12, DOI 10.1186/s13013-017-0128-9
[9]   Comparison of eight published static finite element models of the intact lumbar spine: Predictive power of models improves when combined together [J].
Dreischarf, M. ;
Zander, T. ;
Shirazi-Adl, A. ;
Puttlitz, C. M. ;
Adam, C. J. ;
Chen, C. S. ;
Goel, V. K. ;
Kiapour, A. ;
Kim, Y. H. ;
Labus, K. M. ;
Little, J. P. ;
Park, W. M. ;
Wang, Y. H. ;
Wilke, H. J. ;
Rohlmann, A. ;
Schmidt, H. .
JOURNAL OF BIOMECHANICS, 2014, 47 (08) :1757-1766
[10]   A Computational Biomechanical Investigation of Posterior Dynamic Instrumentation: Combination of Dynamic Rod and Hinged (Dynamic) Screw [J].
Erbulut, Deniz U. ;
Kiapour, Ali ;
Oktenoglu, Tunc ;
Ozer, Ali F. ;
Goel, Vijay K. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (05)