An investigation of the detection capability of pulsed wave duplex Doppler of low grade stenosis using ultrasound contrast agent microbubbles - An in-vitro study

被引:6
作者
Browne, Jacinta E. [1 ,2 ,3 ]
King, Deirdre [4 ]
Fagan, Andrew J. [3 ]
Chari, Deepa [1 ,2 ]
Moran, Carmel M. [5 ]
机构
[1] Tech Univ Dublin, Sch Phys, Med Ultrasound Phys & Technol Grp, Kevin St Campus, Dublin 6, Ireland
[2] Tech Univ Dublin, FOCAS, Kevin St Campus, Dublin 6, Ireland
[3] Mayo Clin, Dept Radiol, Rochester, MN 55901 USA
[4] Blackrock Clin, Med Phys, Dublin, Ireland
[5] Univ Edinburgh, Ctr Cardiovasc Sci, Med Phys, Edinburgh EH16 4TJ, Midlothian, Scotland
关键词
Doppler ultrasound; Ultrasound contrast agents; Anatomical renal artery phantoms; Peak velocity; Peak velocity ratio; RENAL-ARTERY STENOSIS; TISSUE-MIMICKING-MATERIAL; ACOUSTIC PROPERTIES; FREQUENCY; HYPERTENSION; SHIFT; RISK;
D O I
10.1016/j.ultras.2019.04.003
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: The objective of the study was to investigate whether clinically used ultrasonic contrast agents improved the accuracy of spectral Doppler ultrasound in the detection of low grade ( < 50%) renal artery stenosis. Low grade stenoses in the renal artery are notoriously difficult to reliably detect using Doppler ultrasound due to difficulties such as overlying fat and bowel gas. Methods: A range of anatomically-realistic renal artery phantoms with varying low degrees of stenosis (0, 30 and 50%) were constructed and peak velocity data was measured from within the pre-stenotic and mid-stenotic regions in each phantom, for both unenhanced and contrast-enhanced spectral Doppler data acquisitions. The effect of a 20 mm overlying fat layer on the ultrasound beam distortion and phase aberration, and hence on the measured peak velocity data, was also investigated. Results: The overlying fat layer produced a statistically significant underestimation (p < 0.01) in both the peak velocity and peak velocity ratio [Stenotic Region(Vmax)/Pre-stenotic Region(Vmax)] for the 0% and 30% stenosis models, but not the 50% model. A statistically significant increase (p < 0.01) in the peak velocity was found in the contrast-enhanced Doppler spectra; however, no significant difference was found between the unenhanced and contrast enhanced peak velocity ratio data, which suggests that the ratio metric has better diagnostic accuracy. The peak velocity ratios determined for each of the contrast-enhanced phantoms correctly predicted if the phantom had a stenosis and furthermore correctly classified the degree of stenosis. Conclusion: Contrast-enhanced Doppler ultrasound could significantly assist in the early detection of renal artery disease.
引用
收藏
页码:48 / 54
页数:7
相关论文
共 39 条
  • [1] [Anonymous], EUR J ULTRASOUND
  • [2] [Anonymous], 2009, Ultrasound Clin, DOI [10.1016/j.cult.2009.10.011, DOI 10.1016/j.cult.2009.10.011]
  • [3] [Anonymous], FAT LAYERS AFFECT CL
  • [4] [Anonymous], RADIOLOGY
  • [5] [Anonymous], SEMINARS NUCL MED
  • [6] [Anonymous], 1997, J VASC INVESTIG
  • [7] [Anonymous], MED ULTRASONOGR
  • [8] Doppler frequency shift and time-domain velocity enhancement induced by an ultrasonographic contrast agent
    Basseau, F
    Grenier, N
    Trillaud, H
    Douws, C
    Saint-Amon, A
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2000, 19 (03) : 171 - 176
  • [9] The acoustic properties, centered on 20 MHz, of an iec agar-based tissue-mimicking material and its temperature, frequency and age dependence
    Brewin, M. P.
    Pike, L. C.
    Rowland, D. E.
    Birch, M. J.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (08) : 1292 - 1306
  • [10] Investigation of the effect of subcutaneous fat on image quality performance of 2D conventional imaging and tissue harmonic imaging
    Browne, JE
    Watson, AJ
    Hoskins, PR
    Elliott, AT
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (07) : 957 - 964