Surgical fixation with K-wires versus plaster casting in the treatment of dorsally displaced distal radius fractures: protocol for Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT 2)

被引:17
|
作者
Achten, Juul [1 ]
Sones, William [1 ]
Dias, Joseph [2 ]
Hedley, Helen [3 ]
Cook, Jonathan A. [1 ]
Dritsaki, Melina [1 ]
Png, May Ee [1 ]
Gray, Alastair [4 ]
Lamb, Sarah E. [1 ]
Costa, Matthew L. [1 ]
机构
[1] Univ Oxford, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford, England
[2] Leicester Gen Hosp, Dept Orthoped, Leicester, Leics, England
[3] Univ Hosp Coventry & Warwickshire NHS Trust, Dept Orthopaed, Coventry, W Midlands, England
[4] Univ Oxford, Nuffield Dept Populat Hlth, Oxford, England
来源
BMJ OPEN | 2019年 / 9卷 / 03期
关键词
LOCKING-PLATE FIXATION; PERCUTANEOUS FIXATION; KIRSCHNER WIRES; DISABILITY; MANAGEMENT; ADULTS; PAIN;
D O I
10.1136/bmjopen-2018-028474
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Optimal management of distal radius fractures in adults remains controversial. Previous evidence and current clinical guidelines tell us that, if a closed reduction of a dorsally displaced fracture is possible, Kirschner wires (K-wires) are the preferred form of surgical fixation. However, the question remains whether there is any need to perform surgical fixation following a successful closed reduction, or is a simple plaster cast as effective? This is the protocol for a randomised controlled trial of manipulation and surgical fixation with K-wires versus manipulation and casting in the treatment of dorsally displaced distal radius fractures. Methods and analysis Adult patients with an acute dorsally displaced fracture of the distal radius are potentially eligible to take part. Prior to surgery, baseline demographic data, radiographs, data on pain/function using the Patient-Rated Wrist Evaluation Score (PRWE) and health-related quality of life (HRQoL) using the EuroQoL 5-dimension 5-level (EQ-5D-5L) will be collected. A randomisation sequence, stratified by centre, intra-articular extension of the fracture and age, will be administered via a secure web-based service. Each patient will be randomly allocated to either 'manipulation and surgical fixation with K-wires' or 'manipulation and plaster casting'. A clinical assessment, radiographs and records of early complications will be recorded at 6 weeks. PRWE and HRQoL outcome data will be collected at 3, 6 and 12 months post-randomisation. Further information will be requested with regard to healthcare resource use and any complications. Ethics and Dissemination The National Research Ethic Committee approved this study on 6 October 2016 (16/SC/0462). The National Institute for Health Research Health Technology Assessment monograph and a manuscript to a peer-reviewed journal will be submitted on completion of the trial. The results of this trial will substantially inform clinical practice on the clinical and cost-effectiveness of the treatment of this injury.
引用
收藏
页数:7
相关论文
共 45 条
  • [1] Statistical and health economic analysis plan for a randomized controlled trial of surgical fixation with K-wires versus plaster casting in the treatment of dorsally displaced distal radius fractures: DRAFFT2
    Ooms, A. G.
    Png, M. E.
    Cook, J. A.
    Dritsaki, M.
    Dakin, H. A.
    Costa, M. L.
    BONE & JOINT OPEN, 2020, 1 (06): : 245 - 252
  • [2] Surgical fixation with K-wires versus casting in adults with fracture of distal radius: DRAFFT2 multicentre randomised clinical trial
    Costa, Matthew L.
    Achten, Juul
    Ooms, Alexander
    Png, May Ee
    Cook, Jonathan A.
    Lamb, Sarah E.
    Hedley, Helen
    Dias, Joseph
    BMJ-BRITISH MEDICAL JOURNAL, 2022, 376
  • [3] UK DRAFFT: a randomised controlled trial of percutaneous fixation with Kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius
    Costa, Matthew L.
    Achten, Juul
    Plant, Caroline
    Parsons, Nick R.
    Rangan, Amar
    Tubeuf, Sandy
    Yu, Ge
    Lamb, Sarah E.
    HEALTH TECHNOLOGY ASSESSMENT, 2015, 19 (17) : 1 - +
  • [4] UK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius
    Costa, Matthew L.
    Achten, Juul
    Parsons, Nick R.
    Rangan, Amar
    Edlin, Richard P.
    Brown, Jaclyn
    Lamb, Sarah E.
    BMC MUSCULOSKELETAL DISORDERS, 2011, 12
  • [5] Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial
    Costa, Matthew L.
    Achten, Juul
    Parsons, Nick R.
    Rangan, Amar
    Griffin, Damian
    Tubeuf, Sandy
    Lamb, Sarah E.
    BMJ-BRITISH MEDICAL JOURNAL, 2014, 349
  • [6] Moulded cast compared with K-wire fixation after manipulation of an acute dorsally displaced distal radius fracture: the DRAFFT 2 RCT
    Costa, Matthew L.
    Achten, Juul
    Ooms, Alexander
    Png, May Ee
    Cook, Jonathan
    Dritsaki, Melina
    Lamb, Sarah E.
    Lerner, Robin
    Draper, Kylea
    Campolier, Marta
    Dakin, Helen
    McGibbon, Alwin
    Parsons, Nicholas
    Hedley, Helen
    Dias, Joseph
    HEALTH TECHNOLOGY ASSESSMENT, 2022, 26 (11) : 1 - +
  • [7] Internal plate fixation versus plaster in displaced complete articular distal radius fractures, a randomised controlled trial
    Mulders, Marjolein A. M.
    Walenkamp, Monique M. J.
    Goslings, J. Carel
    Schep, Niels W. L.
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [8] Volar Locking Plates Versus K-Wire Fixation of Dorsally Displaced Distal Radius Fractures-A Functional Outcome Study
    Hull, Peter
    Baraza, Njalalle
    Gohil, Milesh
    Whalley, Helen
    Mauffrey, Cyril
    Brewster, Mark
    Costa, Matthew L.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (06): : E125 - E128
  • [9] Meta-analysis for dorsally displaced distal radius fracture fixation: volar locking plate versus percutaneous Kirschner wires
    Zong, Shuang-Le
    Kan, Shi-Lian
    Su, Li-Xin
    Wang, Bin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [10] Functional outcome with Kirschner Wire Fixation Versus Volar Locking Plate Fixation for management of patients with dorsally displaced fractures of distal radius
    Khan, Naveed Ullah
    Khan, Abdul Qadir
    Jameel, Muhammad
    Yaqoob, Hafiz Muhammad
    Khan, Zeeshan
    Bajwa, Mubashar Ahmad
    RAWAL MEDICAL JOURNAL, 2020, 45 (01): : 107 - 110