Monte Carlo simulation of bowtie filter scatter on a wide-cone low-dose CT system

被引:4
|
作者
Liu, Xin [1 ]
Srivastava, Anjali [1 ]
Lee, Hyoung-Koo [1 ]
Hsieh, Jiang [2 ]
机构
[1] Missouri Univ Sci & Technol, Dept Min & Nucl Engn, 301 W14th St, Rolla, MO 65401 USA
[2] GE Hlthcare, Waukesha, WI 53186 USA
来源
MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING | 2013年 / 8668卷
关键词
scatter; Monte Carlo simulation; bowtie filter; artifact; X-RAY SCATTER; MULTIDETECTOR CT; BEAM; RADIATION;
D O I
10.1117/12.2006618
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Knowledge of scatter generated by bowtie filter is crucial for providing artifact free images on the wide-cone low-dose CT scanners. We investigate and determine the scatter level and artifact generated by the widely used bowtie filter in a wide-cone low-dose CT system. Our approach is to use Monte Carlo simulation to estimate the scatter level generated by a bowtie filter made of a material with low atomic number. First, major components of CT systems, such as source, pre-patient collimator, flat filter, bowtie filter, body phantom, and an optional post patient collimator (anti-scatter grid), are built into a 3D model. The scattered photon fluence and the primary transmitted photon fluence are simulated by MCNP5 - a Monte Carlo simulation toolkit. With the increased interests in the low dose and wide coverage CT technology, a tube potential of 80 kVp with more than 10 degree of cone angle is selected. The biased sinogram is created by superimposing scatter signal generated by the bowtie filter onto the primary x-ray beam signal Finally, images with artifacts are reconstructed with the biased signal Methods to reduce bowtie filter scatter are also discussed and demonstrated.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Dynamic Bowtie Filter Design with Monte Carlo Simulation for Cone-Beam CT
    Zhu, Huijie
    Gao, Fuqiang
    Wu, Weiwen
    Liu, Fenglin
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 3160 - 3165
  • [2] Anti-scatter grid evaluation for wide-cone CT
    Melnyk, Roman
    Boudry, John
    Liu, Xin
    Adamak, Mark
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [3] Monte Carlo Simulations of the Effects of Bowtie Filtration on X-Ray Scatter in Cone-Beam CT
    Bootsma, G.
    Verhaegen, F.
    Jaffray, D.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [4] Improved scatter compensation method for low-dose cone-beam CT in SPECT/CT
    Wang, Jiong
    Wiegert, Jens
    Hansis, Eberhard
    Bredno, Joer
    Sowards-Emmerd, David
    Shao, Lingxiong
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [5] Ultrafast Cone-Beam CT Scatter Correction with GPU-Based Monte Carlo Simulation
    Xu, Y.
    Bai, T.
    Yan, H.
    Ouyang, L.
    Wang, J.
    Pompos, A.
    Zhou, L.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 540 - +
  • [6] Validation of a Monte Carlo simulation for dose assessment in dental cone beam CT examinations
    Morant, J. J.
    Salvado, M.
    Casanovas, R.
    Hernandez-Giron, I.
    Velasco, E.
    Calzado, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (03): : 200 - 209
  • [7] Monte Carlo simulation of a cone-beam CT system for lightweight casts
    Thuy Duong Tran
    Ngoc Ha Bui
    Kim Tuan Tran
    Ngoc Toan Tran
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2021, 5 (04) : 504 - 512
  • [8] Monte Carlo simulation of a cone-beam CT system for lightweight casts
    Thuy Duong Tran
    Ngoc Ha Bui
    Kim Tuan Tran
    Ngoc Toan Tran
    Radiation Detection Technology and Methods, 2021, 5 : 504 - 512
  • [9] Monte Carlo simulation of glandular dose in a dedicated breast CT system
    Tang Xiao
    Zhao Wei
    Wang Yan-Fang
    Shu Hang
    Sun Cui-Li
    Wei Cun-Feng
    Cao Da-Quan
    Que Jie-Min
    Shi Rong-Jian
    Wei Long
    CHINESE PHYSICS C, 2012, 36 (07) : 675 - 680
  • [10] Monte Carlo simulation of glandular dose in a dedicated breast CT system
    唐晓
    赵维
    王燕芳
    舒航
    孙翠丽
    魏存峰
    曹大泉
    阙介民
    史戎坚
    魏龙
    中国物理C, 2012, 36 (07) : 675 - 680