The Accuracy of Maxillary Position Using a Computer-Aided Design/Computer-Aided Manufacturing Intermediate Splint Derived Via Surgical Simulation in Bimaxillary Orthognathic Surgery

被引:4
作者
Yamaguchi, Yoshihiro [1 ]
Yamauchi, Kensuke [1 ]
Suzuki, Hikari [1 ]
Saito, Shizu [1 ]
Nogami, Shinnosuke [1 ]
Takahashi, Tetsu [1 ]
机构
[1] Tohoku Univ, Postgrad Sch Dent, Dept Oral & Maxillofacial Surg, Sendai, Miyagi, Japan
关键词
Accuracy; CAD; CAM splint; maxillary position; orthognathic surgery; MODEL SURGERY; REGISTRATION;
D O I
10.1097/SCS.0000000000006305
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The purpose of this study was to assess the clinical interventions and the accuracy of maxillary reposition using a computer-aided design/computer-aided manufacturing (CAD/CAM) splint derived via surgical simulation. Materials and Methods: The retrospective study comprised 24 patients who underwent bimaxillary surgery. The patients were assigned to 1 of 2 groups by a way of maxillary repositioning. One group received conventional intermediate wafers and the other CAD/CAM wafers during Le Fort I osteotomy. We recorded operation time, blood loss, the operative accuracy. Accuracy was analyzed by 3-dimensional computed tomography images before and immediately after the operation. The evaluation points were the right maxillary first incisor (U1), the right maxillary second molar (M2-right), and the left maxillary second molar (M2-left). Results: The 2 groups did not differ significantly in operation time and blood losses. The vertical axis of U1 data differed significantly between the 2 groups (P = 0.008). None of the horizontal, vertical, or anteroposterior axis of M2-right data differed significantly, and anteroposterior axis of M2-left data differed significantly (P = 0.0296). The CAD/CAM group 3-dimensional distance errors were less than those of the conventional group for all points. Conclusion: Placement of CAD/CAM splint allowed highly accurate repositioning; the accuracy exceeded that afforded by conventional model surgery using a facebow and articulator.
引用
收藏
页码:976 / 979
页数:4
相关论文
共 24 条
[1]   3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results - Our experience in 16 cases [J].
Aboul-Hosn Centenero, Samir ;
Hernandez-Alfaro, Federico .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (02) :162-168
[2]   Novel CBCT and Optical Scanner-Based Implant Treatment Planning Using a Stereolithographic Surgical Guide: A Multipronged Diagnostic Approach [J].
Balasundaram, Ashok ;
Gurun, Dincer ;
Neely, Anthony ;
Ash-Rafzadeh, Armand ;
Ravichandra, Juluri .
IMPLANT DENTISTRY, 2014, 23 (04) :401-406
[3]   Computer Planning and Intraoperative Navigation in Orthognathic Surgery [J].
Bell, R. Bryan .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (03) :592-605
[4]   Custom-Machined Miniplates and Bone-Supported Guides for Orthognathic Surgery: A New Surgical Procedure [J].
Brunso, Joan ;
Franco, Maria ;
Constantinescu, Thomas ;
Barbier, Luis ;
Andoni Santamaria, Joseba ;
Alvarez, Julio .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 74 (05) :1061.e1-1061.e12
[5]   Accuracy of virtual surgical planning of orthognathic surgery with aid of CAD/CAM fabricated surgical splintd-A novel 3D analyzing algorithm [J].
Chin, Shih-Jan ;
Wilde, Frank ;
Neuhaus, Michael ;
Schramm, Alexander ;
Gellrich, Nils-Claudius ;
Rana, Majeed .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (12) :1962-1970
[6]   Condylar positioning devices for orthognathic surgery: a literature review [J].
Costa, Fabio ;
Robiony, Massimo ;
Toro, Corrado ;
Sembronio, Salvatore ;
Polini, Francesco ;
Politi, Massimo .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 106 (02) :179-190
[7]   SURGICAL SUPERIOR REPOSITIONING OF THE MAXILLA - WHAT TO DO WITH THE MANDIBLE [J].
EPKER, BN ;
FISH, LC .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1980, 78 (02) :164-191
[8]   Registration of cone beam computed tomography data and intraoral surface scans - A prerequisite for guided implant surgery with CAD/CAM drilling guides [J].
Flugge, Tabea ;
Derksen, Wiebe ;
te Poel, Jobine ;
Hassan, Bassam ;
Nelson, Katja ;
Wismeijer, Daniel .
CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (09) :1113-1118
[9]   Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery [J].
Frisardi, Gianni ;
Chessa, Giacomo ;
Barone, Sandro ;
Paoli, Alessandro ;
Razionale, Armando ;
Frisardi, Flavio .
BMC MEDICAL IMAGING, 2011, 11
[10]   Accuracy of a Computer-Aided Surgical Simulation Protocol for Orthognathic Surgery: A Prospective Multicenter Study [J].
Hsu, Sam Sheng-Pin ;
Gateno, Jaime ;
Bell, R. Bryan ;
Hirsch, David L. ;
Markiewicz, Michael R. ;
Teichgraeber, John F. ;
Zhou, Xiaobo ;
Xia, James J. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (01) :128-142