Assessment of the variation in CT scanner performance (image quality and Hounsfield units) with scan parameters, for image optimisation in radiotherapy treatment planning

被引:45
作者
Davis, Anne T. [1 ,2 ]
Palmer, Antony L. [1 ,2 ]
Pani, Silvia [1 ]
Nisbet, Andrew [1 ,3 ]
机构
[1] Univ Surrey, Fac Engn & Phys Sci, Dept Phys, Guildford, Surrey, England
[2] Portsmouth Hosp NHS Trust, Dept Med Phys, Portsmouth, Hants, England
[3] Royal Surrey Cty Hosp NHS Fdn Trust, Dept Med Phys, Guildford, Surrey, England
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2018年 / 45卷
关键词
Radiotherapy; CT; Imaging; Optimisation; COMPUTED-TOMOGRAPHY; DELINEATION; ASSURANCE; VARIABILITY; SIMULATION; CONVERSION; ONCOLOGY; TARGET; BREAST;
D O I
10.1016/j.ejmp.2017.11.036
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To define a method and investigate how the adjustment of scan parameters affected the image quality and Hounsfield units (HUs) on a CT scanner used for radiotherapy treatment planning. A lack of similar investigations in the literature may be a contributing factor in the apparent reluctance to optimise radiotherapy CT protocols.& para;& para;Method: A Catphan phantom was used to assess how image quality on a Toshiba Aquilion LB scanner changed with scan parameters. Acquisition and reconstruction field-of-view (FOV), collimation, image slice thickness, effective mAs per rotation and reconstruction algorithm were varied. Changes were assessed for HUs of different materials, high contrast spatial resolution (HCSR), contrast-noise ratio (CNR), HU uniformity, scan direction low contrast and CT dose-index.& para;& para;Results: CNR and HCSR varied most with reconstruction algorithm, reconstruction FOV and effective mAs. Collimation, but not image slice width, had a significant effect on CT dose-index with narrower collimation giving higher doses. Dose increased with effective mAs. Highest HU differences were seen when changing reconstruction algorithm: 56 HU for densities close to water and 117 HU for bone-like materials. Acquisition FOV affected the HUs but reconstruction FOV and effective mAs did not.& para;& para;Conclusions: All the scan parameters investigated affected the image quality metrics. Reconstruction algorithm, reconstruction FOV, collimation and effective mAs were most important. Reconstruction algorithm and acquisition FOV had significant effect on HU. The methodology is applicable to radiotherapy CT scanners when investigating image quality optimisation, prior to assessing the impact of scan protocol changes on clinical CT images and treatment plans.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 31 条
  • [1] American Association of Physicists in Medicine, ALL QUAL COMP TOM CT
  • [2] [Anonymous], 1999, 16262 EUR EUR COMM
  • [3] Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179
    Bissonnette, Jean-Pierre
    Balter, Peter A.
    Dong, Lei
    Langen, Katja M.
    Lovelock, D. Michael
    Miften, Moyed
    Moseley, Douglas J.
    Pouliot, Jean
    Sonke, Jan-Jakob
    Yoo, Sua
    [J]. MEDICAL PHYSICS, 2012, 39 (04) : 1946 - 1963
  • [4] CT-based delineation of organs at risk in the head and neck region: DAHANCA, EORTC, GORTEC, HKNPCSG, NCIC CTG, NCRI, NRG Oncology and TROG consensus guidelines
    Brouwer, Charlotte L.
    Steenbakkers, Roel J. H. M.
    Bourhis, Jean
    Budach, Wilfried
    Grau, Cai
    Gregoire, Vincent
    van Herk, Marcel
    Lee, Anne
    Maingon, Philippe
    Nutting, Chris
    O'Sullivan, Brian
    Porceddu, Sandro V.
    Rosenthal, David I.
    Sijtsema, Nanna M.
    Langendijk, Johannes A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 117 (01) : 83 - 90
  • [5] Applications of simulator computed tomography number for photon dose calculations during radiotherapy treatment planning
    Chu, JCH
    Ni, B
    Kriz, R
    Saxena, VA
    [J]. RADIOTHERAPY AND ONCOLOGY, 2000, 55 (01) : 65 - 73
  • [6] Implementation and characterization of a 320-slice volumetric CT scanner for simulation in radiation oncology
    Coolens, C.
    Breen, S.
    Purdie, T. G.
    Owrangi, A.
    Publicover, J.
    Bartolac, S.
    Jaffray, D. A.
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 5120 - 5127
  • [7] Corporation TMS, 2008, OP MAN TOSH SCANN AQ
  • [8] Dosimetric impact of computed tomography calibration on a commercial treatment planning system for external radiation therapy
    Cozzi, L
    Fogliata, A
    Buffa, F
    Bieri, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) : 335 - 338
  • [9] A quality assurance phantom for three-dimensional radiation treatment planning
    Craig, T
    Brochu, D
    Van Dyk, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (04): : 955 - 966
  • [10] Davis A, 2017, BR J RADIOL