Clinical outcomes of ceramic femoral prosthesis in total knee arthroplasty: a systematic review

被引:17
作者
Xiang, Shuai [1 ]
Zhao, Yan [1 ]
Li, Zeng [1 ]
Feng, Bin [1 ]
Weng, Xisheng [1 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Orthopaed Surg, Beijing 100730, Peoples R China
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2019年 / 14卷
关键词
Ceramics; Total knee arthroplasty; Outcomes; LONG-TERM SURVIVORSHIP; TOTAL HIP-ARTHROPLASTY; OXIDIZED ZIRCONIUM; FOLLOW-UP; COBALT-CHROMIUM; POLYETHYLENE WEAR; METAL SENSITIVITY; COMPONENTS; MINIMUM; REPLACEMENT;
D O I
10.1186/s13018-019-1090-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeCeramic bearings have been widely used in total hip arthroplasty (THA), which resulted in satisfactory clinical outcomes due to the excellent tribological characteristics of the implants. However, ceramic components are not commonly used in total knee arthroplasty (TKA) because of brittleness. This study aimed to gather and analyze information regarding the clinical outcomes (including survival without revision, causes of revision, functional outcome, and incidence of loosening) and reach a definitive conclusion about the use of ceramic femoral components in total knee arthroplasty.MethodsMEDLINE, EMBASE, Cochrane, and ClinicalTrials.gov databases were searched for studies that reported the clinical and/or radiological outcomes with or without survival data of ceramic TKA implants and that included more than 10 patients with a minimum of 1year follow-up.ResultsFrom an initial sample of 147, there were 14 studies that met the inclusion criteria. Overall, there was a notable enhancement of joint function after the procedure, with a satisfactory mid- and long-term survival of the ceramic components, which is comparable to that of the conventional alloy components reported previously. In addition, the revision rate was reported to be between 0% and 14.37% according to the included studies. However, revision due to aseptic loosening, wear, and component fracture appeared to be rare, demonstrating the safety of in vivo use of ceramic bearings in the TKA procedure.ConclusionsCeramic TKA implants show similar post-operative clinical results and survival rate compared to their conventional metallic counterparts. Our results confirmed the safety of in vivo use of ceramic bearings in TKA, with rare implant breakage and aseptic loosening. Considering the excellent characteristics of the tribology of ceramics, the clinical use of ceramic prostheses in TKA could be promising.
引用
收藏
页数:10
相关论文
共 44 条
[1]   Total knee arthroplasty with an oxidised zirconium femoral component TEN-YEAR SURVIVORSHIP ANALYSIS [J].
Ahmed, I. ;
Salmon, L. J. ;
Waller, A. ;
Watanabe, H. ;
Roe, J. P. ;
Pinczewski, L. A. .
BONE & JOINT JOURNAL, 2016, 98B (01) :58-64
[2]   The bisurface total knee replacement: A unique design for flexion - Four-to-nine-year follow-up study [J].
Akagi, M ;
Nakamura, T ;
Matsusue, Y ;
Ueo, T ;
Nishijyo, K ;
Ohnishi, E .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (11) :1626-1633
[3]  
Bal B Sonny, 2006, J Knee Surg, V19, P89
[4]   Prospective comparative clinical study of ceramic and metallic femoral components for total knee arthroplasty over a five-year follow-up period [J].
Bergschmidt, Philipp ;
Ellenrieder, Martin ;
Bader, Rainer ;
Kluess, Daniel ;
Finze, Susanne ;
Schwemmer, Benjamin ;
Mittelmeier, Wolfram .
KNEE, 2016, 23 (05) :871-876
[5]   Adhesive strength of total knee endoprostheses to bone cement - analysis of metallic and ceramic femoral components under worst-case conditions [J].
Bergschmidt, Philipp ;
Dammer, Rebecca ;
Zietz, Carmen ;
Finze, Susanne ;
Mittelmeier, Wolfram ;
Bader, Rainer .
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2016, 61 (03) :281-289
[6]   Prospective multi-centre study on a composite ceramic femoral component in total knee arthroplasty: Five-year clinical and radiological outcomes [J].
Bergschmidt, Philipp ;
Bader, Rainer ;
Ganzer, Dirk ;
Hauzeur, Christian ;
Lohmann, Christoph H. ;
Krueger, Alexander ;
Ruether, Wolfgang ;
Tigani, Domenico ;
Rani, Nicola ;
Luis Esteve, Jose ;
Lopez Prats, Fernando ;
Zorzi, Claudio ;
Madonna, Vincenzo ;
Rigotti, Stefano ;
Benazzo, Francesco ;
Rossi, Stefano Marco Paolo ;
Mittelmeier, Wolfram .
KNEE, 2015, 22 (03) :186-191
[7]   Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years - A six- to 11-year evaluation [J].
Bizot, P ;
Hannouche, D ;
Nizard, R ;
Witvoet, J ;
Sedel, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (02) :190-194
[8]   Long-term survivorship of a medial-pivot total knee system compared with other cemented designs in an arthroplasty registry [J].
Bordini, Barbara ;
Ancarani, Cristina ;
Fitch, David A. .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2016, 11
[9]   Long-term followup after mobile-bearing total knee replacement [J].
Buechel, FF .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :40-50
[10]   What Can Be Learned From Minimum 20-year Followup Studies of Knee Arthroplasty? [J].
Callaghan, John J. ;
Martin, Christopher T. ;
Gao, Yubo ;
Pugely, Andrew J. ;
Liu, Steve S. ;
Goetz, Devon D. ;
Kelley, Scott S. ;
Johnston, Richard C. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (01) :94-100