Flexural Strength Behaviour of Bolted Built-Up Cold-Formed Steel Beam with Outstand and Extended Stiffener

被引:18
作者
Muftah, Fadhluhartini [1 ]
Sani, Mohd Syahrul Hisyam Mohd [1 ]
Kamal, Mohd Mawardi Mohd [1 ]
机构
[1] Univ Teknol Mara, Fac Civil Engn, Kampus Jengka, Bandar Jengka 26400, Pahang, Malaysia
关键词
Flexural strength behaviour; Bolted built-up; Cold-formed steel; Beam; Stiffener; COMPRESSION; SECTIONS; DESIGN; TESTS; WEB;
D O I
10.1007/s13296-018-0157-0
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cold-formed steel (CFS) is a popular structural and non-structural material that is utilised as roof truss, wall panel and storage racks. But nowadays, CFS is selected and proposed as column and beam in building construction. CFS with open-section and very thin thickness is prone to deform and buckle in large condition. Therefore, the problem must be solved by proposing a new section that is matched up or formed of two or more open-sections to be one new section, shape and cross-section area. There are two types of channel-section and a connection is used to produce a bolted built-up CFS beam in the study. The first type is jointed with bolt and nut on stiffener or lipped, which is known as outstand stiffener, and another type is connected by locating the bolt and nut on web element and recognised as extended stiffeners. The objective of the study is to determine the flexural strength and load-deformation behaviour of both types of bolted built-up CFS section. Then, the experimental result is verified with the Standard of Practice, American Iron and Steel Institute and BS EN 1993-1-3, Design of steel structures (2006). As a result, bolted built-up CFS beam with extended stiffener and a span of bolt with constant value of 22.5mm is expressed as a good result of flexural strength. In addition, the flexural strength of both beams is dependent only on spacing or bolt location.
引用
收藏
页码:719 / 732
页数:14
相关论文
共 24 条
  • [11] Compression tests of built-up cold-formed steel hollow flange sections
    Kesawan, Sivakumar
    Mahendran, Mahen
    Dias, Yomal
    Zhao, Wen -Bin
    [J]. THIN-WALLED STRUCTURES, 2017, 116 : 180 - 193
  • [12] Experimental investigation on laser welded connections for built-up cold-formed steel beams
    Landolfo, R.
    Mammana, O.
    Portioli, F.
    Di Lorenzo, G.
    Guerrieri, M. R.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (01) : 196 - 208
  • [13] Investigation on flexural strength of cold-formed thin-walled steel beams with built-up box section
    Li, Ying-Lei
    Li, Yuan-Qi
    Shen, Zu-Yan
    [J]. THIN-WALLED STRUCTURES, 2016, 107 : 66 - 79
  • [14] Li YS, 2010, PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2010, VOL 1: CODES AND STANDARDS, P89
  • [15] Investigation on slenderness ratios of built-up compression members
    Liu, Jui-Ling
    Lue, Dung M.
    Lin, Ching H.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (01) : 237 - 248
  • [16] Piyawat K, 2012, J STRUCTURAL ENG, V139, P1
  • [17] Raghul V, 2015, INT J ADV ENG RES TE, V3, P108
  • [18] Evaluation of the slenderness ratio in built-up cold-formed box sections
    Reyes, Wilson
    Guzman, Andres
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (06) : 929 - 935
  • [19] Serrette RL., 2004, J. Struct. Eng. ASCE, V9, P170, DOI [10.1061/(ASCE)1084-0680(2004)9:3(170), DOI 10.1061/(ASCE)1084-0680(2004)9:3(170)]
  • [20] Beam tests of cold-formed steel built-up sections with web perforations
    Wang, Liping
    Young, Ben
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 115 : 18 - 33